If the fault domain with STATUS shown in the table below is displayed on the Protection Domain window of the VSP One SDS Block Administrator, follow the action below.

STATUS

Description

Action

Error

One or more storage nodes in the applicable fault domain are either blocked or could not be blocked.

Verify the status of storage nodes in the applicable fault domain. If all storage nodes are either blocked or could not be blocked*, there might be a power or network failure. Verify the following and take appropriate action.

  • Are you powered by a storage system or peripheral device?

  • Are the cables for storage systems and network peripherals connected correctly?

  • Is the network that accesses the storage system working properly?

* If the storage node is either blocked or could not be blocked, the status will be one of the following:

"TemporaryBlockage","MaintenanceBlockage","PersistentBlockage","InstallationFailed",

"TemporaryBlockageFailed","MaintenanceBlockageFailed",

"RemovalFailedAndTemporaryBlockage","RemovalFailedAndMaintenanceBlockage",

"RemovalFailedAndPersistentBlockage","RemovalFailedAndMultipleFailures"