Installing an extended MIB

Virtual Storage Platform One SDS Block System Administrator Guide

Version
1.16.x
Audience
anonymous
Part Number
MK-24VSP1SDS001-03

To reference the data received by an SNMP command (Get, etc.) or a trap, an extended MIB file of VSP One SDS Block must be included in the SNMP manager.

The name of the extended MIB file is as follows:

  • File name: sdsExMib -<version>-<number>.mib

(Bare metal) You can obtain the extended MIB file in the product media.

(Cloud) You can obtain the extended MIB file from the download server.

If you updated the storage software, obtain the file for which the <version> part of the name is the same as the version of the updated storage software.

The structure of the extended MIB of VSP One SDS Block is as follows:

OID

Name

Description

R/W attribute

Remarks

1

sdsSystemInformation(1)

System information of Hitachi Virtual Storage Platform One SDS Block

R

2

sdsTrapInformation(2)

SNMP trap information

-

Neither writable nor readable

sdsSystemInformation

OID

Name

Description

Remarks

1

sdsProductName

Product name

Fixed to: Hitachi Virtual Storage Platform One SDS Block

2

sdsSoftwareVersion

Operating software version

Storage software version

3

sdsExMibVersion

Version of the extended MIB supported by the operating software

Version of the extended MIB of the storage node

This version is different from the version of storage software.

4

sdsStorageNodeIdTable

List of IDs of storage nodes in a storage cluster

Array of storage node IDs

5

sdsStorageNodeInformationTable

(Bare metal) Hardware information of storage nodes in a storage cluster

(Cloud) Information about the EC2 instance on which the storage node is running

See the following table.

sdsStorageNodeInformationTable

OID

Name

Description

Setting

1

sdsStorageNodeNickName

Node name of the storage node

Node name of the storage node

2

sdsStorageNodeServerModel

Server model of the storage node

(Bare metal) Server model of the storage node

(Cloud) Model name of the EC2 instance on which the storage node is running

3

sdsStorageNodeServerSerialNumber

Serial number of the storage node

(Bare metal) Serial number of the storage node

(Cloud) ID of the EC2 instance on which the storage node is running

sdsTrapInformation

OID

Name

Description

Setting

1

sdsInternalID

Device manufacturer's serial number

System ID

2

sdsEventLog

Event log

See the following table.

sdsEventLog

OID

Name

Description

Setting

1

sdsDateAndTime

Date and time when the event was detected

YYYY/MM/DD

hh:mm:ss.msec

2

sdsSeverity

Severity of the event

"Critical", "Error", or "Warning"

3

sdsMessageId

Message ID

Message ID of the event

4

sdsEventName

Event name

Unique event name

5

sdsEventMessage

Detailed message of event content

Event description

6

sdsCategory

Failure category

Event category

7

sdsID

Individual ID of the event

Event ID

8

sdsNodeLocation

ID of the storage node which registered the event log

ID of the storage node