Message ID |
Message |
---|---|
KARS05000-C |
An internal processing error occurred while the configuration of the drive is being changed. [Event Name] Internal error [Category] Drive [Solution] Collect the logs, and then contact customer support. |
KARS05001-E |
The drive was blocked. (Storage node ID = xxx, Drive ID = xxx) [Event Name] Drive blockade [Category] Drive |
KARS05002-E |
Capacity is not enough. (Drive WWID = xxx, Drive capacity = xxx, Minimum capacity required = xxx) [Event Name] Non supported drive detected [Category] Drive [Solution] Replace with a drive of higher capacity than the minimum capacity required. |
KARS05003-E |
The drive you are trying to add is not supported. (Storage node ID = xxx, Drive WWID = xxx, Vendor:Model = [StorageDeviceVendor:StorageDeviceModel]) [Event Name] Unsupported drive detected [Category] Drive [Solution] Replace with a supported drive. |
KARS05004-E |
The maximum transfer length of the drive is less than 1024 KiB. (Storage node ID = xxx, Drive WWID = xxx, Maximum transfer length = xxx) [Event Name] Unsupported drive detected [Category] Drive [Solution] Perform the following steps in the order listed until the phenomenon changes. 1. Replace with a supported drive. 2. Replace with a supported disk controller, and then update the driver for the disk controller to the latest version. If the phenomenon persists, collect the logs, and then contact customer support. |
KARS05007-E |
The drive that you are trying to add cannot be used because the disk controller is not supported. (Storage node ID = xxx, Drive WWID = xxx) [Event Name] Conditions for drive use are not met [Category] Drive |
KARS05008-E |
A device driver error was detected. (Storage node ID = xxx) [Event Name] Device driver error [Category] Drive [Solution] Collect the logs, and then contact customer support. |
KARS05009-E |
The drive you attempted to add could not be formatted. (Storage node ID = xxx, Drive WWID = xxx, Vendor:Model = [StorageDeviceVendor:StorageDeviceModel]) [Event Name] Drive format error [Category] Drive |
KARS05010-E |
The drive was blocked because the drive is no longer recognizable. (Storage node ID = xxx, Drive ID = xxx) [Event Name] Drive blockade [Category] Drive |
KARS05011-E |
The drive was blocked due to an I/O error. (Storage node ID = xxx, Drive ID = xxx) [Event Name] Drive blockade [Category] Drive |
KARS05012-E |
The drive was blocked due to an I/O error. (Storage node ID = xxx, Drive ID = xxx) [Event Name] Drive blockade [Category] Drive |
KARS05013-E |
On/off state of the locator LED could not be changed. [Cause] An unregistered drive ID is specified. [Solution] Verify the specified drive ID, and then retry the operation. |
KARS05014-E |
On/off state of the locator LED could not be changed. [Cause] Operation with the locator LED was unsuccessful because the drive was already removed or a failure occurred in the drive or locator LED. |
KARS05015-E |
On/off state of the locator LED could not be changed. [Cause] The operation cannot be performed due to software update in progress. [Solution] Wait until the software update is completed, and then retry the operation. |
KARS05016-E |
On/off state of the locator LED could not be changed. [Cause] The storage node on which the specified drive is installed is not running correctly. |
KARS05017-E |
On/off state of the locator LED could not be changed. [Cause] Accesses to the database are congested, or the database is not operating correctly. |
KARS05018-E |
On/off state of the locator LED could not be changed. [Cause] An unexpected error occurred. |
KARS05019-E |
Capacity is not enough. (Drive serial number = xxx, Drive capacity = xxx, Minimum capacity required = xxx) [Event Name] Non supported drive detected [Category] Drive [Solution] Replace with a drive of higher capacity than the minimum capacity required. |
KARS05020-E |
The drive you attempted to add could not be formatted. (Storage node ID = xxx, Drive serial number = xxx) [Event Name] Drive format error [Category] Drive |
KARS05021-E |
The drive you attempted to add could not be recognized. (Storage node ID = xxx, Drive WWID = xxx, Vendor:Model = [StorageDeviceVendor:StorageDeviceModel]) [Event Name] Drive recognition failure [Category] Drive |
KARS05022-I |
Drive removal succeeded for all drives subject to spare node switchover. [Event Name] Drive removal completion [Category] Drive |
KARS05023-W |
Drive removal was unsuccessful. (Drive ID = xxx) [Event Name] Drive removal failure [Category] Drive |
KARS05024-W |
Drive removal was unsuccessful. [Event Name] Drive removal failure [Category] Drive |
KARS05025-E |
Drive auto-recovery was unsuccessful. [Event Name] Drive auto-recovery unsuccessful [Category] Drive |
KARS05026-E |
Drive auto-recovery was unsuccessful. (Drive ID = xxx) [Event Name] Drive auto-recovery unsuccessful [Category] Drive |
KARS05027-I |
Drive auto-recovery was completed. (Drive ID = xxx) [Event Name] Drive auto-recovery completion [Category] Drive |
KARS05028-I |
Temporary I/O slowdown was detected. (Drive ID = xxx) [Event Name] I/O slowdown detection [Category] Drive [Solution] No action is required because the problem is only temporary. However, if the same event log is repeatedly output in a short period of time, replace the drive. |
KARS05029-E |
The storage node could not be added due to the insufficient number of drives. (Storage node = xxx, Job ID = xxx) [Event Name] Insufficient drives [Category] Drive [Solution] Verify the number of drives required for storage node addition, and then add drives. |
KARS05030-E |
The storage node could not be added because the disk controller does not meet requirements. (Storage node = xxx, Job ID = xxx) [Event Name] Conditions for drive use are not met [Category] Drive [Solution] Verify that the configuration and settings of the disk controller meet requirements. |
KARS05031-E |
A drive that does not meet requirements was detected. The storage node could not be added because the number of available drives is insufficient. (Storage node = xxx, Job ID = xxx) [Event Name] Unsupported drive detected [Category] Drive [Solution] Verify all the drives installed on the storage node to be added, and then replace the drives that do not meet requirements. |