Messages KARS05000-KARS05999

Virtual Storage Platform One SDS Block Message Reference

Version
1.15.x
Audience
anonymous
Part Number
MK-24VSP1SDS007-02

Message ID

Message

KARS05000-C

An internal processing error occurred while the configuration of the drive is being changed.

[Event Name]

Internal error

[Category]

Drive

[Solution]

Collect the logs, and then contact customer support.

KARS05001-E

The drive was blocked. (Storage node ID = xxx, Drive ID = xxx)

[Event Name]

Drive blockade

[Category]

Drive

KARS05002-E

Capacity is not enough. (Drive WWID = xxx, Drive capacity = xxx, Minimum capacity required = xxx)

[Event Name]

Non supported drive detected

[Category]

Drive

[Solution]

Replace with a drive of higher capacity than the minimum capacity required.

KARS05003-E

The drive you are trying to add is not supported. (Storage node ID = xxx, Drive WWID = xxx, Vendor:Model = [StorageDeviceVendor:StorageDeviceModel])

[Event Name]

Unsupported drive detected

[Category]

Drive

[Solution]

Replace with a supported drive.

KARS05004-E

The maximum transfer length of the drive is less than 1024 KiB. (Storage node ID = xxx, Drive WWID = xxx, Maximum transfer length = xxx)

[Event Name]

Unsupported drive detected

[Category]

Drive

[Solution]

Perform the following steps in the order listed until the phenomenon changes. 1. Replace with a supported drive. 2. Replace with a supported disk controller, and then update the driver for the disk controller to the latest version. If the phenomenon persists, collect the logs, and then contact customer support.

KARS05007-E

The drive that you are trying to add cannot be used because the disk controller is not supported. (Storage node ID = xxx, Drive WWID = xxx)

[Event Name]

Conditions for drive use are not met

[Category]

Drive

KARS05008-E

A device driver error was detected. (Storage node ID = xxx)

[Event Name]

Device driver error

[Category]

Drive

[Solution]

Collect the logs, and then contact customer support.

KARS05009-E

The drive you attempted to add could not be formatted. (Storage node ID = xxx, Drive WWID = xxx, Vendor:Model = [StorageDeviceVendor:StorageDeviceModel])

[Event Name]

Drive format error

[Category]

Drive

KARS05010-E

The drive was blocked because the drive is no longer recognizable. (Storage node ID = xxx, Drive ID = xxx)

[Event Name]

Drive blockade

[Category]

Drive

KARS05011-E

The drive was blocked due to an I/O error. (Storage node ID = xxx, Drive ID = xxx)

[Event Name]

Drive blockade

[Category]

Drive

KARS05012-E

The drive was blocked due to an I/O error. (Storage node ID = xxx, Drive ID = xxx)

[Event Name]

Drive blockade

[Category]

Drive

KARS05013-E

On/off state of the locator LED could not be changed.

[Cause]

An unregistered drive ID is specified.

[Solution]

Verify the specified drive ID, and then retry the operation.

KARS05014-E

On/off state of the locator LED could not be changed.

[Cause]

Operation with the locator LED was unsuccessful because the drive was already removed or a failure occurred in the drive or locator LED.

KARS05015-E

On/off state of the locator LED could not be changed.

[Cause]

The operation cannot be performed due to software update in progress.

[Solution]

Wait until the software update is completed, and then retry the operation.

KARS05016-E

On/off state of the locator LED could not be changed.

[Cause]

The storage node on which the specified drive is installed is not running correctly.

KARS05017-E

On/off state of the locator LED could not be changed.

[Cause]

Accesses to the database are congested, or the database is not operating correctly.

KARS05018-E

On/off state of the locator LED could not be changed.

[Cause]

An unexpected error occurred.

KARS05019-E

Capacity is not enough. (Drive serial number = xxx, Drive capacity = xxx, Minimum capacity required = xxx)

[Event Name]

Non supported drive detected

[Category]

Drive

[Solution]

Replace with a drive of higher capacity than the minimum capacity required.

KARS05020-E

The drive you attempted to add could not be formatted. (Storage node ID = xxx, Drive serial number = xxx)

[Event Name]

Drive format error

[Category]

Drive

KARS05021-E

The drive you attempted to add could not be recognized. (Storage node ID = xxx, Drive WWID = xxx, Vendor:Model = [StorageDeviceVendor:StorageDeviceModel])

[Event Name]

Drive recognition failure

[Category]

Drive

KARS05022-I

Drive removal succeeded for all drives subject to spare node switchover.

[Event Name]

Drive removal completion

[Category]

Drive

KARS05023-W

Drive removal was unsuccessful. (Drive ID = xxx)

[Event Name]

Drive removal failure

[Category]

Drive

KARS05024-W

Drive removal was unsuccessful.

[Event Name]

Drive removal failure

[Category]

Drive

KARS05025-E

Drive auto-recovery was unsuccessful.

[Event Name]

Drive auto-recovery unsuccessful

[Category]

Drive

KARS05026-E

Drive auto-recovery was unsuccessful. (Drive ID = xxx)

[Event Name]

Drive auto-recovery unsuccessful

[Category]

Drive

KARS05027-I

Drive auto-recovery was completed. (Drive ID = xxx)

[Event Name]

Drive auto-recovery completion

[Category]

Drive

KARS05028-I

Temporary I/O slowdown was detected. (Drive ID = xxx)

[Event Name]

I/O slowdown detection

[Category]

Drive

[Solution]

No action is required because the problem is only temporary. However, if the same event log is repeatedly output in a short period of time, replace the drive.

KARS05029-E

The storage node could not be added due to the insufficient number of drives. (Storage node = xxx, Job ID = xxx)

[Event Name]

Insufficient drives

[Category]

Drive

[Solution]

Verify the number of drives required for storage node addition, and then add drives.

KARS05030-E

The storage node could not be added because the disk controller does not meet requirements. (Storage node = xxx, Job ID = xxx)

[Event Name]

Conditions for drive use are not met

[Category]

Drive

[Solution]

Verify that the configuration and settings of the disk controller meet requirements.

KARS05031-E

A drive that does not meet requirements was detected. The storage node could not be added because the number of available drives is insufficient. (Storage node = xxx, Job ID = xxx)

[Event Name]

Unsupported drive detected

[Category]

Drive

[Solution]

Verify all the drives installed on the storage node to be added, and then replace the drives that do not meet requirements.