VMware ESXi

Virtual Storage Platform One SDS Block Virtual Private Storage Administrator Guide

Version
1.15.x
Audience
anonymous
Part Number
MK-24VSP1SDS003-02

Common settings

In the case of VMware ESXi 6.X (including 5.X), apply the following updates and KBs.

  • VMware ESXi5.5 Update3 and KB2146717

  • VMware ESXi6.0 Update2 and KB2145663

Note that you do not need to change the setting value for SCSI Timeout because this value is 140 seconds by default, which is greater than the requirement for a compute node (120 seconds).

Alternate path software setting

No additional settings are required.

Inter-guest cluster setting

For a device in which the inter-guest cluster (MSCS, etc.) uses reserved volumes (SCSI-2, SCSI-3), change "perennially-reserved" to TRUE from each VMware ESXi (see KB). Make this setting irrespective of the storage configuration.

  • ESXi/ESX hosts with visibility to RDM LUNs being used by MSCS nodes with RDMs may take a long time to start or during LUN rescan (1016106)

    https://kb.vmware.com/s/article/1016106