Message ID |
Message |
---|---|
KARS08000-E |
A request for stopping the storage cluster could not be accepted. [Cause] A request for stopping the storage cluster could not be accepted due to a currently-running operation that conflicts or other cause. |
KARS08100-I |
The storage cluster started. [Event Name] Storage cluster start [Category] Service |
KARS08101-I |
Stops the storage cluster. [Event Name] Storage cluster stopping started [Category] Service |
KARS08102-I |
The I/O function stopped. [Event Name] Storage cluster I/O stop [Category] Service |
KARS08103-E |
The storage node, xxx was blocked. [Event Name] Storage node temporary blockage [Category] StorageNode [Solution] Recover the target storage node. Note: The same event log might be notified multiple times. If the following conditions are met, ignore this message:
|
KARS08104-E |
Update of the storage software to the target version was aborted because the cluster master node was not redundant. [Event Name] Invalid software update conditions (Insufficient redundancy of the cluster master node) [Category] StorageCluster [Solution] See the event logs, and recover the storage node from the failure. Then, perform storage software update again. |
KARS08105-I |
The storage cluster is running in maintenance mode. It changes to normal mode the next time it restarts. [Event Name] The storage cluster is in maintenance mode [Category] StorageCluster |
KARS08107-E |
An internal error occurred while the storage cluster was being stopped. [Event Name] The storage cluster failed to stop due to an internal error [Category] Service [Solution] Wait a while and execute the operation again. If the error occurs again, collect the logs, and then contact customer support. |
KARS08108-E |
Storage node starting cannot be verified. (Storage node ID = xxx) [Event Name] Storage node start failed [Category] StorageNode [Solution] Verify that the storage node is powered on and the network is properly connected. |
KARS08109-I |
The storage cluster is running in initializing storage controller mode. It changes to normal mode the next time it restarts. [Event Name] Storage cluster is in initializing storage controller mode [Category] StorageCluster |
KARS08110-I |
Storage node starting could be verified. (Storage node ID = xxx) [Event Name] Storage node starting verification [Category] StorageNode |
KARS08111-I |
Storage cluster starting resumed. [Event Name] Resuming storage cluster start [Category] StorageCluster |
KARS08112-E |
Storage cluster starting was suppressed. [Event Name] Storage cluster starting suppression [Category] StorageCluster |
KARS08113-C |
The storage cluster cannot be started because a failure exceeding fault tolerance of the storage cluster occurred. [Event Name] Starting the storage cluster failure (Exceeds the fault tolerance of the storage cluster) [Category] StorageCluster [Solution] Collect the logs, and then contact customer support. |
KARS08114-E |
Storage cluster forced starting was canceled because a failure exceeding fault tolerance of the storage cluster occurs. [Event Name] Storage cluster forced starting cancellation [Category] StorageCluster |
KARS08115-E |
The storage cluster cannot be started forcibly. [Event Name] Invalid storage cluster forced starting conditions [Category] StorageCluster [Solution] Verify whether storage cluster forced starting is possible. If it is possible, retry the operation. If the same error occurs, collect the logs, and then contact customer support. |
KARS08116-E |
The storage cluster cannot be started forcibly. [Cause] The storage cluster does not meet forced starting conditions. [Solution] Verify whether storage cluster forced starting is possible. If it is possible, retry the operation. If the same error occurs, collect the logs, and then contact customer support. |
KARS08117-E |
The storage cluster cannot be started forcibly. [Event Name] Storage cluster forced starting unavailable [Category] StorageCluster |
KARS08118-E |
The storage cluster cannot be started forcibly. [Cause] The storage cluster is not in a state where start processing can be resumed. |
KARS08119-E |
Instruction for starting the storage cluster forcibly was unsuccessful. [Event Name] Storage cluster forced starting instruction failed (Internal error) [Category] StorageCluster [Solution] Wait a while and execute the operation again. If the error occurs again, collect the logs, and then contact customer support. |
KARS08120-E |
Instruction for starting the storage cluster forcibly was unsuccessful. [Cause] An unexpected error occurred. [Solution] Wait a while and execute the operation again. If the error occurs again, collect the logs, and then contact customer support. |
KARS08121-E |
The storage cluster is being blocked because an abnormal error occurred while the storage cluster was being shut down. [Event Name] Storage cluster blocking (Abnormal error occurred during storage cluster shutdown) [Category] StorageCluster |
KARS08122-E |
Starting the storage cluster failed. [Event Name] Starting the storage cluster failure [Category] StorageCluster |
KARS08123-I |
Forcibly stops the storage cluster. [Event Name] Storage cluster force stopping started [Category] Service |
KARS08124-C |
The system cannot continue operation because a failure exceeding fault tolerance of the storage cluster occurred. The storage cluster is blocked. (Storage node ID = xxx) [Event Name] Failure exceeding fault tolerance of the storage cluster occurred due to storage node failure [Category] StorageCluster |
KARS08150-E |
The cluster master node xxx was blocked. [Event Name] Cluster master node temporarily blockage [Category] StorageNode [Solution] Change the role or perform recovery of the target storage node. |
KARS08151-I |
The role change of the storage nodes is started. (Promoted storage node ID = xxx, Demoted storage node ID = xxx, Job ID = xxx) [Event Name] Storage node role change started [Category] StorageNode |
KARS08152-I |
The role change of the storage nodes is completed. (Promoted storage node ID = xxx, Demoted storage node ID = xxx, Job ID = xxx) [Event Name] Storage node role change completed [Category] StorageNode |
KARS08153-E |
The role of the storage nodes could not be changed. (Promoted storage node ID = xxx, Demoted storage node ID = xxx, Job ID = xxx) [Event Name] Storage node role change failed [Category] StorageNode [Solution] If an event log indicating another error is output, take action referring to the event log. If the same error occurs, collect the logs, and then contact customer support. |
KARS08154-E |
Status of the intended storage node is invalid. (Promoted storage node ID = xxx, Demoted storage node ID = xxx, Job ID = xxx) [Event Name] Storage node role change failed (Invalid target storage nodes) [Category] StorageNode [Solution] Verify that the appropriate storage node is selected for the intended storage node. |
KARS08155-E |
The status of the storage cluster is invalid. (Job ID = xxx) [Event Name] Storage node role change failed (Invalid storage cluster status) [Category] StorageNode [Solution] Verify the status of the storage cluster. |
KARS08156-E |
An operation that cannot be performed concurrently is being performed. (Job ID = xxx) [Event Name] Storage node role change failed (Concurrent operation prohibited) [Category] StorageNode [Solution] Wait until the operation that cannot be performed concurrently is complete, and then retry the operation. If the same error occurs, collect the logs, and then contact customer support. |
KARS08157-E |
The role change of the storage nodes cannot be performed. (Job ID = xxx) [Event Name] Storage node role change failed (Invalid role change) [Category] StorageNode [Solution] To be able to change the role of storage node, the storage cluster must first be stopped. Stop the storage cluster, and then retry the operation. If the same error occurs, collect the logs, and then contact customer support. |
KARS08158-E |
The role of the storage nodes could not be changed. (Promoted storage node ID = xxx, Demoted storage node ID = xxx) [Cause] An error occurred while the operation was being performed. [Solution] If an event log indicating another error is output, take action referring to the event log. If the same error occurs, collect the logs, and then contact customer support. |
KARS08159-E |
The role of the storage nodes cannot be changed. (Promoted storage node ID = xxx, Demoted storage node ID = xxx) [Cause] The status of the intended storage node is invalid. [Solution] Select a storage node that satisfies the conditions, and then retry the operation. |
KARS08160-E |
The role of the storage nodes cannot be changed. [Cause] The status of the storage cluster is invalid. [Solution] Wait until the status of the storage cluster is ready, and then retry the operation. |
KARS08161-E |
An operation that can not be performed concurrently is being performed. [Cause] The operation for the storage cluster conflicts with another one. [Solution] Wait until the operation that cannot be performed concurrently is complete, and then retry the operation. If the same error occurs, collect the logs, and then contact customer support. |
KARS08162-E |
The role of the storage nodes cannot be changed. [Cause] The role change of the storage nodes cannot be performed. [Solution] To be able to change the role of storage node, the storage cluster must first be stopped. Stop the storage cluster, and then retry the operation. If the same error occurs, collect the logs, and then contact customer support. |
KARS08163-E |
The number of cluster master nodes per fault domain is invalid. (Job ID = xxx) [Event Name] Storage node role change failed (Invalid number of cluster master nodes per fault domain) [Category] StorageNode |
KARS08164-E |
The role of the storage nodes could not be changed. [Cause] The number of cluster master nodes per fault domain is invalid. |
KARS08170-E |
The request could not be executed. (Job ID = xxx) [Event Name] Internal error [Category] StorageNode [Solution] Wait a while, and then retry the operation. If the same error occurs, collect the logs, and then contact customer support. |
KARS08171-E |
The request could not be executed. (Job ID = xxx) [Event Name] Internal error [Category] StorageNode [Solution] Wait a while, and then retry the operation. If the same error occurs, collect the logs, and then contact customer support. |
KARS08172-E |
The request could not be executed. (Job ID = xxx) [Event Name] Internal error [Category] StorageNode [Solution] Wait a while, and then retry the operation. If the same error occurs, collect the logs, and then contact customer support. |
KARS08173-E |
Another operation is running. (Job ID = xxx) [Event Name] Exclusive control error [Category] StorageNode [Solution] Wait a while, and then retry the operation. If you are performing another update operation, wait until it is complete, and then retry the operation. If the phenomenon does not change, collect the logs, and then contact customer support. |
KARS08175-E |
The request could not be executed. (Job ID = xxx) [Event Name] Internal error [Category] StorageNode [Solution] Wait a while, and then retry the operation. If the same error occurs, collect the logs, and then contact customer support. |
KARS08176-E |
The request could not be executed. (Job ID = xxx) [Event Name] Internal error [Category] StorageNode [Solution] Wait a while, and then retry the operation. If the same error occurs, collect the logs, and then contact customer support. |
KARS08177-E |
The request could not be executed. (Job ID = xxx) [Event Name] Internal error [Category] StorageNode [Solution] Wait a while, and then retry the operation. If the same error occurs, collect the logs, and then contact customer support. |
KARS08178-E |
The request could not be executed. [Cause] An internal error occurred. [Solution] Wait a while, and then retry the operation. If the same error occurs, collect the logs, and then contact customer support. |
KARS08179-E |
The request could not be executed. (Job ID = xxx) [Event Name] Invalid storage node ID specification [Category] StorageNode [Solution] Verify the specified storage node ID, and then retry the operation. |
KARS08180-E |
The request could not be executed. [Cause] An invalid storage node ID was specified. [Solution] Verify the specified storage node ID, and then retry the operation. |
KARS08200-E |
Connection with the DNS server is not possible. (DNS server = xxx, Storage node ID = xxx) [Event Name] DNS server connection error [Category] Service [Solution] Verify that the settings of the DNS server with which the storage node is connected is correct and the DNS server is running normally. Also, verify that the network between the storage node and DNS server is normal. If any problems occur, resolve them. |
KARS08201-I |
Connection recovered for all the DNS servers. (Storage node ID = xxx) [Event Name] DNS server connection to recover [Category] Service |
KARS08202-E |
Connection with the NTP server is not possible. (Storage node ID = xxx) [Event Name] NTP server connection error [Category] Service |
KARS08203-I |
Connection recovered for the NTP server. (NTP server = xxx, Storage node ID = xxx) [Event Name] NTP server connection to recover [Category] Service |
KARS08204-W |
An error was detected when accessing the system drive of the storage node. (Storage node ID = xxx) [Event Name] System drive error detection [Category] StorageNode |
KARS08205-W |
Delays in access response of the storage node system drive were detected. (Storage node ID = xxx) [Event Name] Delayed system drive access response detected [Category] StorageNode |
KARS08206-I |
Delays in access response of the storage node system drive have recovered. (Storage node ID = xxx) [Event Name] Delayed system drive access response recovered [Category] StorageNode |
KARS08300-W |
Control port link down was detected. The control port status is Warning. The active port was switched. (Storage node ID = xxx, Control port MAC address = xxx) [Event Name] Control port link down [Category] ControlPort |
KARS08301-W |
Control port link down was detected. The control port status is Warning. (Storage node ID = xxx, Control port MAC address = xxx) [Event Name] Control port link down [Category] ControlPort |
KARS08302-E |
Control port link down was detected. The control port status is Error. (Storage node ID = xxx, Control port MAC address = xxx) [Event Name] Control port link down [Category] ControlPort |
KARS08303-E |
Control port link down was detected. The control port status is Error. (Storage node ID = xxx, Control port (primary) MAC address = xxx, Control port (secondary) MAC address = xxx) [Event Name] Control port link down [Category] ControlPort |
KARS08304-I |
Control port connection recovery was detected. The control port status is Warning. (Storage node ID = xxx, Control port MAC address = xxx) [Event Name] Control port connection recovery [Category] ControlPort |
KARS08305-I |
Control port connection recovery was detected. The control port status is normal. (Storage node ID = xxx, Control port MAC address = xxx) [Event Name] Control port connection recovery [Category] ControlPort |
KARS08306-I |
Control port connection recovery was detected. The control port status is normal. (Storage node ID = xxx, Control port (primary) MAC address = xxx, Control port (secondary) MAC address = xxx) [Event Name] Control port connection recovery [Category] ControlPort |
KARS08307-E |
The control port status could not be obtained. (Storage node ID = xxx, Control port MAC address = xxx) [Event Name] Control port status acquisition failure [Category] ControlPort |
KARS08308-E |
The control port status could not be obtained. (Storage node ID = xxx, Control port (primary) MAC address = xxx, Control port (secondary) MAC address = xxx) [Event Name] Control port status acquisition failure [Category] ControlPort |
KARS08309-W |
Internode port link down was detected. The Internode port status is Warning. The active port was switched. (Storage node ID = xxx, Internode port MAC address = xxx) [Event Name] Internode port link down [Category] InternodePort |
KARS08310-W |
Internode port link down was detected. The Internode port status is Warning. (Storage node ID = xxx, Internode port MAC address = xxx) [Event Name] Internode port link down [Category] InternodePort |
KARS08311-E |
Internode port link down was detected. The internode port status is Error. (Storage node ID = xxx, Internode port MAC address = xxx) [Event Name] Internode port link down [Category] InternodePort |
KARS08312-E |
Internode port link down was detected. The internode port status is Error. (Storage node ID = xxx, Internode port (primary) MAC address = xxx, Internode port (secondary) MAC address = xxx) [Event Name] Internode port link down [Category] InternodePort |
KARS08313-I |
Internode port connection recovery was detected. The internode port status is Warning. (Storage node ID = xxx, Internode port MAC address = xxx) [Event Name] Internode port connection recovery [Category] InternodePort |
KARS08314-I |
Internode port connection recovery was detected. The internode port status is normal. (Storage node ID = xxx, Internode port MAC address = xxx) [Event Name] Internode port connection recovery [Category] InternodePort |
KARS08315-I |
Internode port connection recovery was detected. The internode port status is normal. (Storage node ID = xxx, Internode port (primary) MAC address = xxx, Internode port (secondary) MAC address = xxx) [Event Name] Internode port connection recovery [Category] InternodePort |
KARS08316-E |
The internode port status could not be obtained. (Storage node ID = xxx, Internode port MAC address = xxx) [Event Name] Internode port status acquisition failure [Category] InternodePort |
KARS08317-E |
The internode port status could not be acquired. (Storage node ID = xxx, Internode port (primary) MAC address = xxx, Internode port (secondary) MAC address = xxx) [Event Name] Internode port status acquisition failure [Category] InternodePort |
KARS08318-I |
The message suppression function of the control port has started. (Storage node ID = xxx) [Event Name] Control port message suppression function start [Category] ControlPort |
KARS08319-I |
The message suppression function of the internode port has started. (Storage node ID = xxx) [Event Name] Internode port message suppression function start [Category] InternodePort |
KARS08320-I |
The message suppression function of the control port has stopped. The number of message suppressions is displayed. (Storage node ID = xxx, Number of suppressions = xxx) [Event Name] Control port message suppression function end [Category] ControlPort |
KARS08321-I |
The message suppression function of the internode port has stopped. The number of message suppressions is displayed. (Storage node ID = xxx, Number of suppressions = xxx) [Event Name] Internode port message suppression function end [Category] InternodePort |
KARS08322-E |
Control port link down was detected. The control port status is Error. (Storage node ID = xxx, Control port MAC address = xxx) [Event Name] Control port link down [Category] ControlPort |
KARS08323-I |
Control port connection recovery was detected. The control port status is normal. (Storage node ID = xxx, Control port MAC address = xxx) [Event Name] Control port connection recovery [Category] ControlPort |
KARS08330-W |