The following tables describe the Power and Server status LED indicators for the Hitachi Virtual Storage Platform One File.

Table. Power status LED (green)
LEDs Meaning
Green Normal operational mode of an active cluster node.
Medium flash (once every .8 seconds) The server is available to host file services but is not currently doing so. This also occurs if no EVS is configured, or if all EVSs are running on the other node in a cluster.
Fast flash (five flashes per second) The server is rebooting.
Off The server is not powered up.
Table. Server status LED (amber)
LEDs Meaning
Amber Critical failure and the server is not operational.
Slow flash (once every three seconds) System shutdown has failed. Flashes once every three seconds.
Medium flash (once every 0.8 seconds) The server needs attention, and a non-critical failure has been detected, for example, a fan or power supply has failed. Flashes once every 0.8 seconds.
Off Normal operation.