The following table lists potential error conditions that might occur during installation of new storage and provides instructions for resolving the conditions. If you cannot resolve an error condition, contact customer support.
Error Condition | Recommended Action |
---|---|
The logical devices are not recognized by the system. | Be sure that the READY indicator
lights on the storage system are ON. Be sure that the LUNs are properly configured. The LUNs for each target ID must start at 0 and continue sequentially without skipping any numbers. |
The file system cannot be created. | Be sure that the device name is
entered correctly with mkfs. Be sure that the LU is properly connected and partitioned. |