Accessing the Alert Notifications window

SNMP Agent User Guide for VSP E Series

Version
93-07-2x
93-07-0x
93-06-8x
Audience
anonymous
Part Number
MK-97HM85027-11

You can configure SNMP traps using the Alert Notifications window in the maintenance utility.

You must have the Storage Administrator (Initial Configuration) role to perform this task.


  1. In the maintenance utility, open the Alert Notifications window by one of the following ways:

    • When you use Device Manager - Storage Navigator, from the Maintenance Utility menu in the main window, select Alert Notifications.
    • When you use Hitachi Storage Advisor Embedded, in the navigation bar, click (Settings), and then select Alert Notifications.
    • When you directly logged in to the maintenance utility, click Administration > Alert Notifications.
  2. In the Alert Notifications window, click Set Up.
  3. In the Set Up Alert Notifications window, select the SNMP tab.
  4. For Notification Alert, select one of the following:
    • All (Sends alerts of all SIMs.)
    • Host Report (Sends alerts only of SIMs that report to hosts. Alert destinations are common to Syslog, SNMP, and Email.)
  5. Confirm the settings, and then click Apply.