VSP G350 mechanical specifications

Virtual Storage Platform G350, G370 Hardware Reference Guide

Version
88-07-0x
Audience
anonymous
Part Number
MK-97HM85012-06

The following tables list the system specifications for VSP G350.

CBSS/CBSL controller chassis

Item

Specification

Physical dimension

(W x D x H) (mm)

483 × 813 × 88 mm

Weight/Mass (kg)

(Approximate)

16.1 kg (CBSS)

15.9 kg (CBSL)

Start-up time (min)1

5 to 8 (min)

Required height

(EIA unit)2

2U

Heat output (W)

218 W (CBSS)

192 W (CBSL)

Power consumption (VA)

226 W (CBSS)

200 W (CBSL)

Air flow (m3/min)3

4.0 (m3/min) (CBSS)

3.5 (m3/min) (CBSL)

Notes:
  1. The start-up time might be longer in proportion to the number of drive trays connected. With a maximum configuration 1 controller chassis and 19 drive trays, start-up time is approximately 8 minutes.
  2. Can be mounted on the RKU rack. For the mounting, special rails for the rack and decoration panels are required separately depending on the number of the mounted storage systems.
  3. The value is at maximum level.

Drive chassis

Item

Component

Specification

Physical dimension

(W x D x H) (mm)

DBS/DBSE

482 × 565 × 88.2 mm

DBL/DBLE

DB60

482 × 1,029 × 176 mm

Weight/Mass (kg)

(Approximate)

DBS/DBSE

17 kg

DBL/DBLE

17.4 kg

DB60

36 kg

Start-up time (min)1

DBS/DBSE

5 to 8 (min)

DBL/DBLE

DB60

Required height

(EIA unit)2

DBS/DBSE

2U

DBL/DBLE

DB60

4U

Heat output (W)

DBS/DBSE

116 W

DBL/DBLE

124 W

DB60

184 W

Power consumption (VA)

DBS/DBSE

126 VA

DBL/DBLE

144 VA

DB60

191 VA

Air flow (m3/min)3

DBS/DBSE

2.2 (m3/min)

DBL/DBLE

2.2 (m3/min)

DB60

5.1 (m3/min)

Notes:
  1. The start-up time might be longer in proportion to the number of drive trays connected. With a maximum configuration 1 controller chassis and 19 drive trays, start-up time is approximately 8 minutes.
  2. Can be mounted on the RKU rack. For the mounting, special rails for the rack and decoration panels are required separately depending on the number of the mounted storage systems.
  3. The value is at maximum level.

Drive type

Item

Component

Specification

Supported data capacity

CBSS

DBS/DBSE

472.61, 576.39, 945.23, 1152.79, 1729.29, 1890.46, 2305.58, 3780.92, 7561.85, 15048.49, 30095.00 GB

CBSL

DBL/DBLE

5874.22, 9790.36 GB

DB60

1152.79, 1729.29, 5874.22, 9790.36, 13706.5 GB

Maximum storage system capacity (physical capacity)

Using 2.4 TB (2.5-inch SFF) HDD

402 TiB

Using 14 TB (3.5-inch LFF) HDD

3,141 TiB

Using 15 TB (2.5-inch SFF) SSD

2,627 TiB

Using 30 TB (2.5-inch SFF) SSD

5,255TiB

Maximum mountable quantity (unit)1

CBSS

DBS/DBSE

24 (total per chassis)

CBSS (1) + DBS/DBSE (7): 192

CBSS (1) + DBL/DBLE (7): 108

CBSL

DBL/DBLE

12

CBSL (1) + DBS/DBSE (7): 180

CBSL (1) + DBL/DBLE (7): 96

DB60

60

CBSS (1) + DB60 (4): 264

CBSL (1) + DB60 (4): 252

Maximum number of spare drives2

CBSS

DBS/DBSE

16

CBSL

DBL/DBLE

DB60

Note:
  1. When mounting storage system and mixing DBS/DBSE, DBL/DBLE, and DB60 drive trays, the maximum mountable quantity (unit) may vary.

  2. Available as spare or data disks.

Host interface

Item

Specification

Interface type

16/32 Gbps FC (Optical)

10 Gbps iSCSI (Optical)

10 Gbps iSCSI (Copper)

Data transfer speed

(Max. speed for transfer to host)

400 Mbps (FC)

800 Mbps (FC)

1600 Mbps (FC)

3200 Mbps (FC)

1000 Mbps (iSCSI - Optical)

1000 Mbps (iSCSI - Copper)

Number of ports

16/32 Gbps FC (Optical): 16

10 Gbps iSCSI (Optical): 8

10 Gbps iSCSI (Copper): 8

Transferred block size

(bytes)

512

Maximum number of hosts via FC switch

255

Maximum number of hosts via network switch

255

Battery life

Storage system intake temperature CBSS CBSL

Up to 75.2º F (24º C)

5 years 5 years

Up to 86º F (30º C)

5 years 4 years

Up to 93.2º (34º C)

4 years 3 years

Up to 104º (40º C)

3 years 2 years

RAID specifications

Item

Specification

RAID level*

SAS/SAS7.2K/Flash drive mounted: 1/5/6

RAID configuration

RAID1: 2D+2D, 4D+4D

RAID5: 3D+1P, 4D+1P, 6D+1P, 7D+1P

RAID6: 6D+2P, 12D+2P, 14D+2P

Maximum number of parity groups

88

Maximum volume size

3 TB (when using the LDEVs of other Storage Systems: 4TB)

Maximum volumes/host groups and iSCSI targets

2048

Maximum volumes/parity groups

2048

*A storage system configured with RAID6, RAID 5, or RAID 1 provides redundancy and enhances data reliability. However, there is still a possibility of losing data caused by unforeseeable hardware or software failure. Users should always follow recommended best practices and back up all data.

Internal logic specifications (CBSS/CBSL)

Item

Specification

Control memory

Flash memory: 32 MB

L3 cache memory: 4 MB

SDRAM: 1 GB

Data assurance method

Data bus: Parity

Cache memory: ECC (1 bit correction, 2 bit detection)

Drive: Data assurance code

Cache specifications

Item

Specification

Capacity (GB per system)

128 GB

Control method

Read LRU/Write after

Battery backup

Provided

Backup duration*

Unrestricted (Saving to a nonvolatile memory)

*Non-volatile data in the cache memory is protected against sudden power failure. The backup operation writes data into a cache, even if a power interruption occurs, and transferred to the cache flash memory.

Insulation performance

Item

Specification

Insulation withstand voltage

AC 1,500 V (100mA, 1min)

Insulation resistance

DC 500 V, 10 MΩ or more