The following tables list the system specifications for VSP G350.
CBSS/CBSL controller chassis
Item |
Specification |
---|---|
Physical dimension (W x D x H) (mm) |
483 × 813 × 88 mm |
Weight/Mass (kg) (Approximate) |
16.1 kg (CBSS) |
15.9 kg (CBSL) |
|
Start-up time (min)1 |
5 to 8 (min) |
Required height (EIA unit)2 |
2U |
Heat output (W) |
218 W (CBSS) |
192 W (CBSL) |
|
Power consumption (VA) |
226 W (CBSS) |
200 W (CBSL) |
|
Air flow (m3/min)3 |
4.0 (m3/min) (CBSS) |
3.5 (m3/min) (CBSL) |
|
Notes:
|
Drive chassis
Item |
Component |
Specification |
---|---|---|
Physical dimension (W x D x H) (mm) |
DBS/DBSE |
482 × 565 × 88.2 mm |
DBL/DBLE |
||
DB60 |
482 × 1,029 × 176 mm |
|
Weight/Mass (kg) (Approximate) |
DBS/DBSE |
17 kg |
DBL/DBLE |
17.4 kg |
|
DB60 |
36 kg |
|
Start-up time (min)1 |
DBS/DBSE |
5 to 8 (min) |
DBL/DBLE |
||
DB60 |
||
Required height (EIA unit)2 |
DBS/DBSE |
2U |
DBL/DBLE |
||
DB60 |
4U |
|
Heat output (W) |
DBS/DBSE |
116 W |
DBL/DBLE |
124 W |
|
DB60 |
184 W |
|
Power consumption (VA) |
DBS/DBSE |
126 VA |
DBL/DBLE |
144 VA |
|
DB60 |
191 VA |
|
Air flow (m3/min)3 |
DBS/DBSE |
2.2 (m3/min) |
DBL/DBLE |
2.2 (m3/min) |
|
DB60 |
5.1 (m3/min) |
|
Notes:
|
Drive type
Item |
Component |
Specification |
|
---|---|---|---|
Supported data capacity |
CBSS DBS/DBSE |
472.61, 576.39, 945.23, 1152.79, 1729.29, 1890.46, 2305.58, 3780.92, 7561.85, 15048.49, 30095.00 GB |
|
CBSL DBL/DBLE |
5874.22, 9790.36 GB |
||
DB60 |
1152.79, 1729.29, 5874.22, 9790.36, 13706.5 GB |
||
Maximum storage system capacity (physical capacity) |
Using 2.4 TB (2.5-inch SFF) HDD |
402 TiB |
|
Using 14 TB (3.5-inch LFF) HDD |
3,141 TiB |
||
Using 15 TB (2.5-inch SFF) SSD |
2,627 TiB |
||
Using 30 TB (2.5-inch SFF) SSD |
5,255TiB | ||
Maximum mountable quantity (unit)1 |
CBSS DBS/DBSE |
24 (total per chassis) |
CBSS (1) + DBS/DBSE (7): 192 CBSS (1) + DBL/DBLE (7): 108 |
CBSL DBL/DBLE |
12 |
CBSL (1) + DBS/DBSE (7): 180 CBSL (1) + DBL/DBLE (7): 96 |
|
DB60 |
60 |
CBSS (1) + DB60 (4): 264 CBSL (1) + DB60 (4): 252 |
|
Maximum number of spare drives2 |
CBSS DBS/DBSE |
16 |
|
CBSL DBL/DBLE |
|||
DB60 |
|||
Note:
|
Host interface
Item |
Specification |
---|---|
Interface type |
16/32 Gbps FC (Optical) 10 Gbps iSCSI (Optical) 10 Gbps iSCSI (Copper) |
Data transfer speed (Max. speed for transfer to host) |
400 Mbps (FC) 800 Mbps (FC) 1600 Mbps (FC) 3200 Mbps (FC) 1000 Mbps (iSCSI - Optical) 1000 Mbps (iSCSI - Copper) |
Number of ports |
16/32 Gbps FC (Optical): 16 10 Gbps iSCSI (Optical): 8 10 Gbps iSCSI (Copper): 8 |
Transferred block size (bytes) |
512 |
Maximum number of hosts via FC switch |
255 |
Maximum number of hosts via network switch |
255 |
Battery life
Storage system intake temperature | CBSS | CBSL |
---|---|---|
Up to 75.2º F (24º C) |
5 years | 5 years |
Up to 86º F (30º C) |
5 years | 4 years |
Up to 93.2º (34º C) |
4 years | 3 years |
Up to 104º (40º C) |
3 years | 2 years |
RAID specifications
Item |
Specification |
---|---|
RAID level* |
SAS/SAS7.2K/Flash drive mounted: 1/5/6 |
RAID configuration |
RAID1: 2D+2D, 4D+4D RAID5: 3D+1P, 4D+1P, 6D+1P, 7D+1P RAID6: 6D+2P, 12D+2P, 14D+2P |
Maximum number of parity groups |
88 |
Maximum volume size |
3 TB (when using the LDEVs of other Storage Systems: 4TB) |
Maximum volumes/host groups and iSCSI targets |
2048 |
Maximum volumes/parity groups |
2048 |
*A storage system configured with RAID6, RAID 5, or RAID 1 provides redundancy and enhances data reliability. However, there is still a possibility of losing data caused by unforeseeable hardware or software failure. Users should always follow recommended best practices and back up all data. |
Internal logic specifications (CBSS/CBSL)
Item |
Specification |
---|---|
Control memory |
Flash memory: 32 MB L3 cache memory: 4 MB SDRAM: 1 GB |
Data assurance method |
Data bus: Parity Cache memory: ECC (1 bit correction, 2 bit detection) Drive: Data assurance code |
Cache specifications
Item |
Specification |
---|---|
Capacity (GB per system) |
128 GB |
Control method |
Read LRU/Write after |
Battery backup |
Provided |
Backup duration* |
Unrestricted (Saving to a nonvolatile memory) |
*Non-volatile data in the cache memory is protected against sudden power failure. The backup operation writes data into a cache, even if a power interruption occurs, and transferred to the cache flash memory. |
Insulation performance
Item |
Specification |
---|---|
Insulation withstand voltage |
AC 1,500 V (100mA, 1min) |
Insulation resistance |
DC 500 V, 10 MΩ or more |