The SVP provides four RJ-45 ports:
- Two ports connect to the storage system controllers (one port for each controller).
- One port connects to the IP network of the user.
- One port connects to a user-supplied management console PC.
Note: This product is also designed for IT power distribution systems with phase-to-phase voltage.
Three of the four RJ-45 ports (which connect to the controllers and the IP network) are configured as a bridge. The SVP can be addressed using the default IP address 192.168.0.15.
In the unlikely event you cannot connect to the SVP using the default IP address, use the following emergency login:
http://<default SVP IP address>/dev/storage/<model number><system serial number>/emergency.do. For example:
Storage system model number | Storage system serial number | URL |
---|---|---|
8320004 |
456789 |
http://192.168.0.15/dev/storage/8320004456789/emergency.do |
8340004 |
456789 |
http://192.168.0.15/dev/storage/8340004456789/emergency.do |
8360004 |
456789 |
http://192.168.0.15/dev/storage/8360004456789/emergency.do |
Users are responsible for adopting the appropriate security procedures with the SVP, including:
- Applying Windows security patches.
- Turning on automatic Windows updates or using the manual Windows update method.
- Installing antivirus software that has been tested and approved by Hitachi.