The VSP G130 include an optional, separate 1U service processor (SVP) dedicated to host an element manager (Storage Navigator). The SVP operates independently from the CPU of the storage system and operating system, and provides out‑of‑band configuration and management of the storage system. The SVP also monitors and collects performance data for key components of the storage system to enable diagnostic testing and analysis for customer support.
- Two ports connect to the storage system controllers (one port for each controller).
- One port connects to the IP network of the user.
- One port connects to a user-supplied management console PC.
Three of the four RJ-45 ports (which connect to the controllers and the IP network) are configured as a bridge. The SVP can be addressed using the default IP address 192.168.0.15.
Storage system model number | Storage system serial number | URL |
---|---|---|
8320004 |
456789 |
http://192.168.0.15/dev/storage/8320004456789/emergency.do |
8340004 |
456789 |
http://192.168.0.15/dev/storage/8340004456789/emergency.do |
8360004 |
456789 |
http://192.168.0.15/dev/storage/8360004456789/emergency.do |
- Applying Windows security patches.
- Turning on automatic Windows updates or using the manual Windows update method.
- Installing antivirus software that has been tested and approved by Hitachi.
SVP specifications
The following table lists the hardware specifications for the service processor (Windows 10 IoT Enterprise) provided by Hitachi Vantara.
Item |
Specification |
---|---|
Dimensions |
Height: 1.7 inches (43 mm) Width: 17.2 inches (437 mm) Depth: 9.8 inches (249 mm) Weight: 10 lbs (4.5 kg) |
Processor |
Intel N3710 Pentium processor 4C/4 threads 1.6 GHz 2M cache, 6W |
Memory |
2 x 4 GB DDR3 1600MHz |
Storage media |
1 TB 5400 RPM SATA HDD |
LAN/Network interface card |
1-GbE x 4 ports (on-board NIC) x1 IPMI (BMC) port |
Fans |
2 x 4028 mm 13KPRM 4-pin PWM fans |
Operating system |
Windows 10 Enterprise |
Maximum temperature |
Up to 40° C (104° Fahrenheit) The SVP is supported in high-temperature environments. Do not operate in any location with temperatures above 40°C (104° Fahrenheit). |