The storage systems offer superior performance, resiliency, and agility, featuring response times as low as 41μ, all backed up with the industry’s first and most comprehensive 100% data availability guarantee. The following table lists the key operational and performance specifications for the storage system.
|
Item |
Specification |
|||
|---|---|---|---|---|
|
System |
Number of drives |
Minimum |
4 |
|
|
Maximum |
2.5-inch SAS: 864 2.5-inch NVMe: 96 |
|||
|
RAID group configuration |
RAID 6 |
|
||
| RAID 5 |
|
|||
| RAID 1 |
|
|||
|
Maximum number of spare drives |
88 |
|||
|
Maximum number of volumes |
65,280 |
|||
|
Maximum storage system capacity (physical capacity) |
30 TB 2.5-inch SSD used |
25.9 PB |
||
|
Maximum external configuration |
255 PiB (287 PB) |
|||
|
Memory |
Cache memory capacity |
256 GiB to 1,024 GiB |
||
|
Storage interface |
DKC-drive interface |
|
||
|
Data transfer rate |
|
|||
|
Maximum number of back-end modules |
8 |
|||
|
Device interface |
Supported channel types |
|
||
|
Data transfer rate |
Fibre Channel |
Up to 32 Gbps |
||
|
iSCSI (Optical) |
25 Gbps |
|||
|
Maximum number of front-end modules |
16 |
|||
|
Item |
Specification |
|||
|---|---|---|---|---|
|
System |
Number of drives |
Minimum |
4 |
|
|
Maximum |
2.5-inch SAS: 864 3.5-inch SAS: 960 |
|||
|
RAID group configuration |
RAID 6 |
|
||
| RAID 5 |
|
|||
| RAID 1 |
|
|||
|
Maximum number of spare drives |
88 |
|||
|
Maximum number of volumes |
65,280 |
|||
|
Maximum storage system capacity (physical capacity) |
30 TB 2.5-inch SSD used |
25.9 PB |
||
|
Maximum external configuration |
255 PiB (287 PB) |
|||
|
Memory |
Cache memory capacity |
256 GiB to 1,024 GiB |
||
|
Storage interface |
DKC-drive interface |
|
||
|
Data transfer rate |
12 Gbps |
|||
|
Maximum number of back-end modules |
8 |
|||
|
Device interface |
Supported channel types |
|
||
|
Data transfer rate |
Fibre Channel |
Up to 32 GB/s |
||
|
iSCSI (Optical) |
25 Gbps |
|||
|
Maximum number of front-end modules |
16 |
|||