Output example

System Administrator Guide for Virtual Storage Platform E Series

Version
93-07-0x
Audience
anonymous
Part Number
MK-97HM85028-18

The storage system delivers a report after you send failure information to the event log.

The storage system failure information looks similar to the following example.

# Item Description
1 Overview of the event info Displays the overview of the event information
2 Detail of the event info Displays the selected information

Date: Date of the event occurrence

Time: Time of the event occurrence

Machine: Model name and serial number of the storage system

Refcode: Reference code*

Detail: Detailed failure information*

ActionCode: Includes action code, expected failure parts, and location. A maximum of 8 failure information can be shown.

3 Log name Displays the log type

This is always displayed as "Application"

4 Source Displays the name of the application which issued the event

This is always displayed as "Hitachi Storage Navigator Alert Module"

5 Event ID Displays the event ID

This is always displayed as "10"

6 Level Displays the event alert level
  • Error: Acute or Serious
  • Warning: Moderate
  • Information: Service
7 User This is always displayed as "N/A"
8 OpCode This is always displayed as blank
9 Logged Displays the date and time when the event log was registered
10 Task category This is always displayed as "None"
11 Keywords This is always displayed as "Classic"
12 Computer Displays the computer name on which the event occurred

*For reference code, failure details, and alert level, see the SIM Reference Guide.