Alert Detail window

System Administrator Guide for Virtual Storage Platform E Series

Version
93-07-0x
Audience
anonymous
Part Number
MK-97HM85028-18


Item Description
Alert ID Identifier assigned to each alert
Date and Time Displays the date and time when alerts occurred
Reference Code Displays the SIM reference code
Error Level Displays error level of alerts
  • : No alert.
  • Service: No need to deal with immediately. Errors that are dealt with within periodical maintenance.
  • Warning (Moderate): No need to deal with immediately. Errors that are dealt with within periodical maintenance.
  • Error (Serious): Contact customer support. Take adequate measure as instructed, report and solve the problem.
  • Acute: Contact customer support. Take adequate measure as instructed, report and solve the problem.
Error Section Displays information about the section of an error
Error Detail Displays more detail about the error
Location Displays the location for the error
Concerned Alerts Displays the Alert ID related to the notified alert

Action Codes

Item Description
Action Code Displays the alert action code
Possible Failure Parts Displays the part that might have been the cause of the alert
Location Displays the location for the error

Temperature Monitor window

Displays the temperature information for DKC and DB.

DKC Ambient Temperature table

Item Description
Chassis ID Displays the chassis ID of the storage system.
Measurement Location Displays the measurement location.
Ambient Temperature (degrees C) Displays the ambient temperature in degrees Celsius.

A hyphen (-) is displayed if the DKC is turned off, or the temperature information cannot be acquired due to a unit or network failure.

Export button Displays a window for outputting table information.

DB Internal Temperature table

Item Description
Disk Unit Displays the disk unit of the storage system.
Drive Box Displays the drive box.
Measurement Location Displays the measurement location.
Internal Temperature (degrees C) Displays the internal temperature in degrees Celsius.

Nothing is displayed in the DB internal temperature table when the DKC is turned off. The DB is not displayed in the DB internal temperature table when the temperature information cannot be acquired because the chassis is not installed, the DB is blocked for maintenance, or a unit or network failure occurred.

A hyphen (-) is displayed for VSP E590 and VSP E790 (these models do not have temperature information of DB-00).

Export button Displays a window for outputting table information.