[Remote Replication] Add Path

Audit Log User Guide for VSP E Series

Version
93-07-0x
Audience
anonymous
Part Number
MK-97HM85024-18

Detailed Information

Item

Description

S/N

The serial number of the RCU

MCU LDKC

The LDKC number of the connected LDKC

RCU LDKC

The LDKC number of the paired LDKC

Path Gr.ID

The path group ID. When the path group ID is default setting, "Default" is output.

Controller ID

The controller ID of the RCU

7: VSP G1000/G1500 and VSP F1500, 8: VSP 5000 series, 18: VSP E series, VSP G130, G/F350, G/F370, G/F700, G/F900, VSP G200, G400, G600, G800, and VSP F400, F600, F800, 19: HUS VM

Result

The result of the operation

Normal end: Normal end,

Error(xxxx-yyyyy): Abnormal end

where xxxx: Part code, yyyyy: Error code

MCU Port

The port number of MCU

RCU Port

The port number of RCU

Num. of Port Pairs

Number of pairs of the port to be operated

Num. of RCUs

The number of RCUs set

Example

RMI AP,,[Remote Replication],Add Path,,Normal end,
Seq.=xxxxxxxxxx
+{S/N,MCU LDKC,RCU LDKC,Path Gr.ID,Controller ID,Result}
={411111,0x00,0x00,Default,18,Normal end}
++{MCU Port,RCU Port}
=[{1E,3E},{5E,7E},{1F,3F},{5F,7F},{1G,3G},{5G,7G},{1H,3H}],
Num. of Port Pairs=7
(Snip)
+{S/N,MCU LDKC,RCU LDKC,Path Gr.ID,Controller ID,Result}
={422222,0x00,0x00,Default,18,Normal end}
++{MCU Port,RCU Port}
=[{1E,3E},{5E,7E},{1F,3F},{5F,7F},{1G,3G},{5G,7G},{1H,3H}],
Num. of Port Pairs=7
+Num. of RCUs=xx