Pairresync(RemoteCopy)

Audit Log User Guide for VSP E Series

Version
93-07-0x
Audience
anonymous
Part Number
MK-97HM85024-18
Note:

When you resynchronize UR pairs and GAD pairs in a consistency group, the audit log is registered only once. The audit log is registered only when the pair that uses the representative volume of the consistency group is resynchronized.

Example

Out-of-band,,[Config Command],,,Accept,Seq.=xxxxxxxxxx
+Command=Pairresync(RemoteCopy)
++Copy Kind=Remote
++P-VOL(Port-LUN-LDEV)=1A-2047-0x1A,S-VOL(Port-LUN-LDEV)=1B-3-0x3B,
MCU S/N=412345,RCU S/N=412345,
Virtual Storage Machine S/N=423456,
Write Permission(Update Copy Error)=Enable,
Write Permission(RCU Suspend Failure)=Enable,
Copy Pace(TRK)=1,JNL ID Option=Disable,CTG ID=100,Resync-SWAP=Disable,
CTG Mode(Multi)=Enable,CTG Option=Enable,CTO Option=Enable,
Inflow Control=Enable,Offloading Timer(s)=1,Device Option=Enable
,IO Preference Mode=

Detailed Information

Item

Description

Command

The command name

Copy Kind

The remote copy

Remote is output as the fixed value.

P-VOL(Port-LUN-LDEV)*1

The port number, the LU number, and the LDEV number of the primary volume

The port number and the LU number show the expanded LU of Command Control Interface

The LU number is the absolute LUN*2 of Command Control Interface

S-VOL(Port-LUN-LDEV)*1

The port number, the LU number, and the LDEV number of the secondary volume

The port number and the LU number show the expanded LU of Command Control Interface

No value is output when the option "-swaps" or "-swapp" is specified.

The LU number is the absolute LUN*2 of Command Control Interface

MCU S/N*1

The serial number of the local storage system

RCU S/N*1

The serial number of the remote storage system

No value is output when the option "-swaps" or "-swapp" is specified.

Virtual Storage Machine S/N

The serial number of the virtual storage machine

No value is output when a virtual storage machine is not specified.

Write Permission(Update Copy Error)

The setting status of write permission if an error occurs during update copy

Enable: Enabled, Disable: Disabled

Enable is output when the option "-swaps" or "-swapp" is specified.

Write Permission(RCU Suspend Failure)

The setting status of permission to write to the local storage system if the suspension operation cannot be performed on the remote storage system

Enable: Enabled, Disable: Disabled

Enable is output when the option "-swaps" or "-swapp" is specified.

Copy Pace(TRK)

The track size for copy

JNL ID Option

Indicates whether an option (-jp or -js) is specified for a journal ID

Enable: Specified, Disable: Not specified

Disable is output for pairs other than Universal Replicator ones.

CTG ID

The consistency group ID

No value is output when the option "-swaps" or "-swapp" is specified.

Resync-SWAP

Indicates whether an option (-swaps or -swapp) is specified

Enable: Specified, Disable: Not specified

CTG Mode(Multi)

Indicates whether pairs are specified for consistency groups across multiple storage systems

Enable: Specified, Disable: Not specified

Disable is output for pairs other than Universal Replicator ones.

CTG Option

Indicates whether the consistency group option (-fg) is specified

Enable: Specified, Disable: Not specified

If the option "-swaps" or "-swapp" is specified, Disable is output for Universal Replicator pair.

CTO Option

Indicates whether the CTO option (-cto) is specified

Enable: Specified, Disable: Not specified

Inflow Control

The setting status of the inflow control mode

Enable: Enabled, Disable: Disabled

No value is output when the CTO option is not specified.

Offloading Timer(s)

The time out value for the inflow control in seconds

No value is output when the CTO option is not specified or the inflow control mode is disabled.

Device Option

Indicates whether the volume name defined in the configuration definition file is used

Enable: Used, Disable: Not used

IO Preference Mode

I/O preference mode for when a failure occurs on the remote path between the primary and secondary storage systems (I/O Preference Mode When Remote Path Failed). A value is displayed when I/O Preference Mode When Remote Path Failed is specified.

P-VOL: Primary Volume (the mode in which the primary volume is given priority)

Disable: I/O Preference Mode When Remote Path Failed is disabled.

*1 When a virtual storage machine is specified, the value of the virtual storage machine is output.

*2 For more information about the absolute LUN, see Command Control Interface Installation and Configuration Guide