The following table lists and describes the SIM codes that require action or restoration by service personnel. If a SIM in the table is output, contact customer support.
If you select Host Report for Notification Alert in the Set Up Alert Notifications window, alert notification for SIMs that are reported to the host is sent. If you select All, alert notification for all SIMs is sent.
Reference code |
Description |
Section |
Alert level (Severity) |
Host report |
---|---|---|---|---|
1420xx |
Transmitted data abnormality between MP and GUM |
Processor |
MODERATE |
Yes |
180000 |
Audit Log lost |
DKC environment |
MODERATE |
Yes |
1C0000 |
Detected a specific error code SSB |
DKC environment |
SERVICE |
Yes |
2120xx |
Channel port blocking |
DKC environment |
MODERATE |
Yes |
2130xx |
CHB blocking |
DKC environment |
MODERATE |
Yes |
2140xx |
DKB blocking |
DKC environment |
MODERATE |
Yes |
2153xx |
PECB blocking |
DKC environment |
MODERATE |
Yes |
2154xx |
SWPK blocking |
DKC environment |
MODERATE |
Yes |
2157xx |
PECB warning |
DKC environment |
MODERATE |
Yes |
2180xx |
RIO path closed |
DKC environment |
MODERATE |
Yes |
2190xx |
AL_PA value conflict |
DKC environment |
SERVICE |
Yes |
2193xx |
Link failure1 |
DKC environment |
SERIOUS |
Yes |
2194xx |
Link failure2 |
DKC environment |
SERIOUS |
Yes |
21a8xx |
SFP wrong type |
DKC environment |
MODERATE |
Yes |
21aaxx |
SFP TxFault |
DKC environment |
MODERATE |
Yes |
21abxx |
SFP warning |
Processor |
MODERATE |
Yes |
21acxx |
SFP alarm |
Processor |
MODERATE |
Yes |
21d0xx |
External storage system connection path blocking |
DKC environment |
MODERATE |
Yes |
21d1xx |
External storage system connection path restore |
DKC environment |
SERVICE |
Yes |
21d2xx |
External storage system response delay |
DKC environment |
SERVICE |
Yes |
3070xx |
CHK1A threshold over |
Processor |
SERVICE |
Yes |
3071xx |
CHK1B threshold over |
Processor |
SERVICE |
Yes |
3072xx |
CHK3 threshold over |
Processor |
SERVICE |
Yes |
3073xx |
Processor blocking |
Processor |
MODERATE |
Yes |
3075xx |
CFM Failure |
Cache |
MODERATE |
Yes |
3076xx |
Incorrect SUM value of FM |
Processor |
SERVICE |
Yes |
3077xx |
Processor memory temporary error |
Processor |
SERVICE |
Yes |
3078xx |
BFM error |
Processor |
SERIOUS |
Yes |
3080xx |
WCHK1 dump |
Processor |
MODERATE |
Yes |
388f00 |
PS OFF impossible |
PS(DKC) |
MODERATE |
Yes |
389f00 |
PS OFF impossible (Device reserved) |
PS(DKC) |
MODERATE |
Yes |
3990xx |
Undefined Package is mounted |
Processor |
MODERATE |
Yes |
3991xx |
V-R or serial number is inconsistent |
Processor |
MODERATE |
Yes |
3993xx |
Replace failed |
Processor |
MODERATE |
Yes |
399dxx |
Injustice dc voltage control |
DKC environment |
MODERATE |
Yes |
399exx |
Injustice CEMODE |
DKC environment |
MODERATE |
Yes |
399fxx |
Injustice CEDT |
DKC environment |
MODERATE |
Yes |
39a000 |
The upper temperature limit was exceeded |
DKC environment |
SERVICE |
Yes |
39b0xx |
MP patrol check error |
DKC environment |
SERVICE |
Yes |
3a0xxx |
LDEV Blockade (Effect of microcode error) |
Drive |
MODERATE |
Yes |
3c9500 |
CHB/DKB Type disagreement |
DKC environment |
MODERATE |
Yes |
3c9600 |
No CHB mounted |
Processor |
MODERATE |
Yes |
3c97xx |
iSCSI firmware update warning |
DKC environment |
MODERATE |
Yes |
3c9800 |
ACLF type mismatch detected |
ACLF error |
MODERATE |
Yes |
410000 |
Format complete (Normal end) |
Drive |
SERVICE |
Yes |
410001 |
Format complete (Abnormal end) |
Drive |
SERVICE |
Yes |
410002 |
Format complete (Partial abnormal end) |
Drive |
SERVICE |
Yes |
410100 |
Quick Format finish |
Drive |
SERVICE |
Yes |
410200 |
Parity consistency check completed |
Environment |
SERVICE |
No |
410201 |
Parity consistency check suspended |
Environment |
SERVICE |
No |
410300 |
Parity consistency check abnormality detection |
Environment |
MODERATE |
No |
435xxx |
Drive media error |
Drive |
SERVICE |
Yes |
43axxx |
Drive blockade (media)(with redundancy) |
Drive |
SERIOUS |
Yes |
43dxxx |
Drive blockade (media)(without redundancy) |
Drive |
SERIOUS |
Yes |
469xxx |
Collection Copy/Copyback disabled(drive replace) |
Drive |
MODERATE |
Yes |
46axxx |
Drive Copy/Correction Copy delay |
Drive |
MODERATE |
Yes |
46bxxx |
Drive Copy/Correction Copy delay |
Drive |
MODERATE |
Yes |
46cxxx |
Drive Copy/Correction Copy copy skip |
Drive |
MODERATE |
Yes |
46dxxx |
Drive Copy/Correction Copy copy skip |
Drive |
MODERATE |
Yes |
47dxxx |
Shadow Image Copy abnormal end |
DKC environment |
MODERATE |
Yes |
47e700 |
Forcible suspend by SM volatile |
DKC environment |
MODERATE |
Yes |
47ec00 |
Forcible suspend by SM volatile |
DKC environment |
MODERATE |
Yes |
47fxxx3 |
Volume Migration abnormal end |
DKC environment |
MODERATE |
Yes |
491000 |
Cache overload condition |
Cache |
SERVICE |
Yes |
493xxx |
Cache Write Pending warning threshold exceeded |
Cache Condition |
MODERATE |
No |
4a80xx |
Expander Micro Exchange failed |
DKC environment |
MODERATE |
Yes |
4b3xxx |
Thin Image Option abnormal end |
DKC environment |
MODERATE |
Yes |
4b6xxx |
Correction copy start |
Drive |
SERVICE |
Yes |
4b7xxx |
Correction copy start |
Drive |
SERVICE |
Yes |
4b8xxx |
Correction copy normal end |
Drive |
SERVICE |
Yes |
4b9xxx |
Correction copy normal end |
Drive |
SERVICE |
Yes |
4baxxx |
Correction copy abnormal end |
Drive |
SERIOUS |
Yes |
4bbxxx |
Correction copy abnormal end |
Drive |
SERIOUS |
Yes |
4bcxxx |
Correction copy discontinued |
Drive |
SERVICE |
Yes |
4bdxxx |
Correction copy discontinued |
Drive |
SERVICE |
Yes |
4bexxx |
Correction copy warning end (With blockade LDEV or some error) |
Drive |
SERVICE |
Yes |
4bfxxx |
Correction copy warning end (With blockade LDEV or some error) |
Drive |
SERVICE |
Yes |
4c5xxx |
Flash module drive initialization failed |
Drive |
MODERATE |
Yes |
4c6xxx |
Dynamic sparing start (Drive copy) |
Drive |
SERVICE |
Yes |
4c7xxx |
Dynamic sparing start (Drive copy) |
Drive |
SERVICE |
Yes |
4c8xxx |
Dynamic sparing normal end (Drive copy) |
Drive |
SERVICE |
Yes |
4c9xxx |
Dynamic sparing normal end (Drive copy) |
Drive |
SERVICE |
Yes |
4caxxx |
Dynamic sparing abnormal end (Drive copy) |
Drive |
MODERATE |
Yes |
4cbxxx |
Dynamic sparing abnormal end (Drive copy) |
Drive |
MODERATE |
Yes |
4ccxxx |
Dynamic sparing discontinued (Drive copy) |
Drive |
SERVICE |
Yes |
4cdxxx |
Dynamic sparing discontinued (Drive copy) |
Drive |
SERVICE |
Yes |
4cexxx |
Dynamic sparing warning end (With blockade LDEV or some error) (Drive copy) |
Drive |
SERVICE |
Yes |
4cfxxx |
Dynamic sparing warning end (With blockade LDEV or some error) (Drive copy) |
Drive |
SERVICE |
Yes |
4d1xxx |
Differential area blocking |
Drive |
SERIOUS |
Yes |
4d6xxx |
PDEV Erase Start |
Drive |
SERVICE |
Yes |
4d7xxx |
PDEV Erase Start |
Drive |
SERVICE |
Yes |
4d8xxx |
PDEV Erase Normal End |
Drive |
SERVICE |
Yes |
4d9xxx |
PDEV Erase Normal End |
Drive |
SERVICE |
Yes |
4daxxx |
PDEV Erase Abnormal End |
Drive |
SERVICE |
Yes |
4dbxxx |
PDEV Erase Abnormal End |
Drive |
SERVICE |
Yes |
4e0xxx |
Drive blockade due to Media Sanitization start |
Drive |
SERVICE |
Yes |
4e2xxx |
Media Sanitization start |
Drive |
SERVICE |
Yes |
4e4xxx |
Media Sanitization normal end |
Drive |
SERVICE |
Yes |
4e6xxx |
Media Sanitization abnormal end |
Drive |
MODERATE |
Yes |
4e8xxx |
Media Sanitization warning end |
Drive |
MODERATE |
Yes |
500xxx |
Drive temporary error |
Drive |
SERVICE |
Yes |
503xxx |
Drive media error |
Drive |
SERVICE |
Yes |
505xxx |
Flash module drive internal battery error (ORM) |
Drive |
SERVICE |
Yes |
508xxx |
Flash module drive internal battery error |
Drive |
MODERATE |
Yes |
50axxx |
Flash drive End of life |
Drive |
SERVICE |
Yes |
50dxxx |
Flash module drive End of life |
Drive |
SERVICE |
Yes |
50exxx |
Flash module drive battery capacity shortage |
Drive |
MODERATE |
Yes |
50f000 |
Flash module drive micro-program version warning |
Drive |
MODERATE |
Yes |
610001 |
Backup/restore SM Information failed (Backup) |
SM |
MODERATE |
Yes |
610002 |
Backup/restore SM Information failed (Restore) |
SM |
MODERATE |
Yes |
623xxx |
The DP POOL error is detected |
DKC environment |
MODERATE |
Yes |
623ffe |
DP Pools blocking by Shared Memory volatile |
DKC environment |
MODERATE |
Yes |
632xxx | Auto pool expansion failed due to pool error |
DKC environment |
MODERATE |
Yes |
633xxx | Failed to create, expand, or delete pools |
DKC environment |
MODERATE |
Yes |
660100 |
No free encryption key |
DKC environment |
MODERATE |
Yes |
660200 |
Remaining free encryption key warning |
DKC environment |
SERVICE |
Yes |
6610xx |
Acquisition of encryption key from KMS failed |
DKC environment |
MODERATE |
Yes |
6620xx |
Encryption key setting abnormality |
DKC environment |
SERIOUS |
Yes |
6800xx1 | Dedupe and compression abnormality detect | DKC environment | MODERATE | Yes |
681xxx |
dedupe system volume deletion abnormal end |
DKC environment |
MODERATE |
Yes |
682000 |
dedupe system volume deletion suspended |
DKC environment |
MODERATE |
Yes |
689xxx |
dedupe system volume change comp_acl abnormal end |
DKC environment |
MODERATE |
Yes |
68a0xx |
dedupe and compression performance degradation alert |
DKC environment |
MODERATE |
Yes |
68bxxx |
dedupe and compression meta data access failure |
DKC environment |
MODERATE |
Yes |
760000 |
CUDG detected error |
DKC environment |
MODERATE |
Yes |
7900xx |
BOOT detected error |
DKC environment |
MODERATE |
Yes |
7d000x |
GUM error |
DKC environment |
MODERATE |
Yes |
7d010x |
LAN error (Internal Network) |
DKC environment |
MODERATE |
Yes |
7d020x |
LAN error (CTL1-CTL2) |
DKC environment |
MODERATE |
Yes |
7d050x |
Notification of Alert failed |
DKC environment |
MODERATE |
Yes |
7d06xx |
MP error |
Processor |
MODERATE |
Yes |
7d07xx |
GUM security error detected |
DKC environment |
MODERATE |
Yes |
7d08xx |
Failed to recover GUM configuration information |
DKC environment |
MODERATE |
Yes |
7d0900 |
DKC warning |
Processor |
SERIOUS |
Yes |
7d0axx |
GUM version warning |
DKC environment |
MODERATE |
Yes |
7d0bxx |
Configuration backup failed |
DKC environment |
MODERATE |
Yes |
7d0dxx |
GUM configuration information corrupted |
DKC environment |
MODERATE |
Yes |
7ff102 |
SI |
DKC environment |
SERVICE |
No |
7ff104 |
TI |
DKC environment |
SERVICE |
No |
7ff1063 |
Volume Migration Pair |
DKC environment |
SERVICE |
No |
7ff7xx |
The term of validity is over |
DKC environment |
MODERATE |
Yes |
7ff8xx |
The capacity of validity is over |
DKC environment |
MODERATE |
Yes |
7ff9xx |
The PP is invalid by assumption PP invalidity |
DKC environment |
MODERATE |
Yes |
7ffa00 |
Synchronization time failure |
DKC environment |
SERVICE |
Yes |
ac50xx |
DB power off |
PS(DKU) |
MODERATE |
Yes |
ac51xx |
DB power recovered |
PS(DKU) |
SERVICE |
Yes |
ac6000 |
DKC was set to power error mode |
PS(DKC) |
MODERATE |
Yes |
ac6100 |
DKC was released from power error mode |
PS(DKC) |
SERVICE |
Yes |
ac6200 |
Destaging startup normal |
PS(DKC) |
SERVICE |
Yes |
ac6300 |
Destaging startup failed |
PS(DKC) |
MODERATE |
Yes |
ac800x |
Server failure |
DKC environment |
SERIOUS |
Yes |
ac9100 |
Open host reservation |
DKC environment |
MODERATE |
Yes |
af00xx |
Injustice JP Warning |
DKC environment |
MODERATE |
Yes |
af10xx |
MP Temperature abnormality warning |
DKC environment |
MODERATE |
Yes |
af11xx |
External temperature warning |
DKC environment |
MODERATE |
Yes |
af12xx |
External temperature alarm |
DKC environment |
MODERATE |
Yes |
af13xx |
Thermal monitor warning |
DKC environment |
MODERATE |
Yes |
af20xx |
DKCPS warning |
PS(DKC) |
MODERATE |
Yes |
af21xx |
DKCPS input voltage abnormality |
PS(DKC) |
MODERATE |
Yes |
af30xx |
Environmental microcomputer warning |
DKC environment |
MODERATE |
Yes |
af31xx |
Device movement mode warning |
DKC environment |
MODERATE |
Yes |
af32xx |
Environmental Firmware Update warning |
DKC environment |
MODERATE |
Yes |
af33xx |
Voltage change setting warning |
PS(DKC) |
MODERATE |
Yes |
af40xx |
BKM/BKMF warning |
DKC environment |
MODERATE |
Yes |
af41xx |
Battery replacement should be scheduled |
Battery |
MODERATE |
Yes |
af42xx |
CHBB environmental microcontroller warning |
DKC environment |
MODERATE |
Yes |
af43xx |
SCM environmental microcontroller warning |
DKC environment |
MODERATE |
Yes |
af44xx |
CHBB environmental firmware update warning |
DKC environment |
MODERATE |
Yes |
af45xx |
SCM environmental firmware update warning |
DKC environment |
MODERATE |
Yes |
af46xx |
SWPK temperature warning |
DKC environment |
MODERATE |
Yes |
af48xx |
CHBB voltage change failure warning |
DKC environment |
MODERATE |
Yes |
af49xx |
SCM voltage change failure warning |
DKC environment |
MODERATE |
Yes |
af4axx |
CHBBPS warning |
DKC environment |
MODERATE |
Yes |
af4bxx |
CHBBPS abnormal input voltage |
DKC environment |
MODERATE |
Yes |
af4cxx |
CHBBFAN warning |
DKC environment |
MODERATE |
Yes |
af4dxx | Panel switch warning | DKC environment | MODERATE | Yes |
af4exx | Invalid PS ON warning | DKC environment | MODERATE | Yes |
af50xx |
DBPS warning |
PS(DKU) |
MODERATE |
Yes |
af51xx |
DBPS-1 warning |
PS(DKU) |
MODERATE |
Yes |
af52xx |
DBPS-2 warning |
PS(DKU) |
MODERATE |
Yes |
af60xx |
DBPS input voltage abnormality |
PS(DKU) |
MODERATE |
Yes |
af61xx |
DBPS-1 input voltage abnormality |
PS(DKU) |
MODERATE |
Yes |
af62xx |
DBPS-2 input voltage abnormality |
PS(DKU) |
MODERATE |
Yes |
af7000 |
DB External temperature warning |
DKU environment |
MODERATE |
Yes |
af7100 |
DB External temperature Alarm |
DKU environment |
MODERATE |
Yes |
af80xx |
ENC warning |
DKU environment |
MODERATE |
Yes |
af81xx |
ENC-1 warning |
DKU environment |
MODERATE |
Yes |
af82xx |
ENC-1 warning |
DKU environment |
MODERATE |
Yes |
afa0xx |
CHBB environmental firmware update started |
DKC environment |
SERVICE |
Yes |
afa1xx |
CHBB environmental firmware update is complete |
DKC environment |
SERVICE |
Yes |
afa2xx |
CHBB environmental firmware update was applied |
DKC environment |
SERVICE |
Yes |
afb9xx |
ECTL warning |
DKC environment |
MODERATE |
Yes |
afe4xx |
Life expiry warning for DB air filter |
DKU environment |
SERVICE |
Yes |
aff0xx |
UPS warning |
PS(DKC) |
MODERATE |
Yes |
aff1xx |
GUM warning |
DKC environment |
MODERATE |
Yes |
aff2xx |
CFM error |
Cache |
MODERATE |
Yes |
aff3xx |
FAN warning |
Fan(DKC) |
MODERATE |
Yes |
aff400 |
Life expiry warning for DKC air filter |
DKC environment |
SERVICE |
Yes |
bfc010 |
DKC ALARM LED light on |
Processor |
SERIOUS |
Yes |
cf10xx |
SAS CTL blocking |
DKC environment |
MODERATE |
Yes |
cf11xx |
SAS Port (WideLink) is partially blocked |
DKC environment |
SERVICE |
Yes |
cf12xx2 |
SAS PORT BLOCK |
DKC environment |
MODERATE |
Yes |
cf13xx |
SAS-CTL Error detection |
DKC environment |
SERIOUS |
Yes |
cf14xx2 |
Recovered from ENC temporary failure successfully |
DKC environment |
SERVICE |
Yes |
cf20xx |
PSW blockade |
DKC environment |
MODERATE |
Yes |
cf22xx |
NVMe port blockade |
DKC environment |
MODERATE |
Yes |
cf88xx |
CTL blocking |
DKC environment |
MODERATE |
Yes |
cf8axx |
CTL blockade due to CTL interconnect path failure |
DKC environment |
MODERATE | Yes |
d00xxx |
Remote Copy start |
DKC environment |
SERVICE |
Yes |
d01xxx |
Remote Copy normal end |
DKC environment |
SERVICE |
Yes |
d02xxx |
Pair end |
DKC environment |
SERVICE |
Yes |
d10xxx |
HRC pair status change(MCU command), SMPL -> COPY |
DKC environment |
SERVICE |
Yes |
d11xxx |
HRC pair status change(MCU command), SMPL -> PAIR |
DKC environment |
SERVICE |
Yes |
d12xxx |
HRC pair status change(MCU command), COPY -> PAIR |
DKC environment |
SERVICE |
Yes |
d13xxx |
HRC pair status change(MCU command), COPY -> PSUx |
DKC environment |
SERVICE |
Yes |
d14xxx |
HRC pair status change(MCU command), PAIR -> PSUx |
DKC environment |
SERVICE |
Yes |
d15xxx |
HRC pair status change(MCU command), PAIR -> SMPL |
DKC environment |
SERVICE |
Yes |
d16xxx |
HRC pair status change(MCU command), COPY -> SMPL |
DKC environment |
SERVICE |
Yes |
d17xxx |
HRC pair status change(MCU command), PSUx -> SMPL |
DKC environment |
SERVICE |
Yes |
d18xxx |
HRC pair status change(MCU command), PSUx -> COPY |
DKC environment |
SERVICE |
Yes |
d19xxx |
HRC pair status change(MCU command), COPY -> PSUx |
DKC environment |
SERVICE |
Yes |
d1axxx |
HRC pair status change(MCU command), COPY -> PSUx |
DKC environment |
SERVICE |
Yes |
d1bxxx |
HRC pair status change(MCU command), PSUx -> PSUx |
DKC environment |
SERVICE |
Yes |
d1zxxx |
Status of the R-VOL is changed |
DKC environment |
SERVICE |
Yes |
d40xxx |
Pair suspend(RIO path closed) |
DKC environment |
SERIOUS |
Yes |
d41xxx |
Pair suspend(P-VOL error) |
DKC environment |
SERIOUS |
Yes |
d42xxx |
Pair suspend(S-VOL error) |
DKC environment |
SERIOUS |
Yes |
d44xxx |
Pair suspend(RVOL Suspend report) |
DKC environment |
SERIOUS |
Yes |
d45xxx |
Pair suspend(S-VOL Simplex report) |
DKC environment |
SERIOUS |
Yes |
d46xxx |
Pair suspend(Communication error at RCU) |
DKC environment |
SERIOUS |
Yes |
d47xxx |
Pair suspend(Error detected at RCU) |
DKC environment |
SERIOUS |
Yes |
d4fxxx |
Pair status incorrect |
DKC environment |
SERIOUS |
Yes |
d80xxx |
Volume to be used by UR was defined |
DKC environment |
SERVICE |
Yes |
d81xxx |
Volume used by UR began copying |
DKC environment |
SERVICE |
Yes |
d82xxx |
Volume used by UR completed copying |
DKC environment |
SERVICE |
Yes |
d83xxx |
Volume used by UR received suspension request |
DKC environment |
SERVICE |
Yes |
d84xxx |
Volume used by UR completed suspension transaction |
DKC environment |
SERVICE |
Yes |
d85xxx |
Volume used by UR received request for deletion |
DKC environment |
SERVICE |
Yes |
d86xxx |
Volume used by UR completed deletion |
DKC environment |
SERVICE |
Yes |
d87xxx |
Volume used by UR was defined |
DKC environment |
SERVICE |
Yes |
d88xxx |
Volume used by UR was defined in hold |
DKC environment |
SERVICE |
Yes |
d89xxx |
PVOL used by UR was defined in hold |
DKC environment |
SERVICE |
Yes |
d90xxx |
Change to SVOL was received from MCU, SMPL -> COPY |
DKC environment |
SERVICE |
Yes |
d91xxx |
Change to SVOL was received from MCU, SMPL -> PAIR |
DKC environment |
SERVICE |
Yes |
d92xxx |
Change to SVOL was received from MCU, COPY -> PAIR |
DKC environment |
SERVICE |
Yes |
d93xxx |
Change to SVOL was received from MCU, COPY -> PSUx |
DKC environment |
SERVICE |
Yes |
d94xxx |
Change to SVOL was received from MCU, PAIR -> PSUx |
DKC environment |
SERVICE |
Yes |
d95xxx |
Change to SVOL was received from MCU, PAIR -> SMPL |
DKC environment |
SERVICE |
Yes |
d96xxx |
Change to SVOL was received from MCU, COPY -> SMPL |
DKC environment |
SERVICE |
Yes |
d97xxx |
Change to SVOL was received from MCU, PSUx -> SMPL |
DKC environment |
SERVICE |
Yes |
d98xxx |
Change to SVOL was received from MCU, PSUx -> COPY |
DKC environment |
SERVICE |
Yes |
d99xxx |
Change to SVOL was received from MCU, HOLD -> PAIR |
DKC environment |
SERVICE |
Yes |
d9axxx |
Change to SVOL was received from MCU, HOLD -> COPY |
DKC environment |
SERVICE |
Yes |
d9bxxx |
Change to SVOL was received from MCU, HOLD -> SMPL |
DKC environment |
SERVICE |
Yes |
d9cxxx |
Change to SVOL was received from MCU, SMPL -> PSUx |
DKC environment |
SERVICE |
Yes |
d9dxxx |
Change to SVOL was received from MCU, SMPL -> HOLD |
DKC environment |
SERVICE |
Yes |
d9exxx |
Change to SVOL was received from MCU, PSUx -> HOLD |
DKC environment |
SERVICE |
Yes |
d9fxxx |
Change to SVOL was received from MCU, PAIR -> COPY |
DKC environment |
SERVICE |
Yes |
da0xxx |
Change to SVOL was received from RCU, SUSPEND REQ. |
DKC environment |
SERVICE |
Yes |
da1xxx |
Change to SVOL was received from RCU, SUSPEND END |
DKC environment |
SERVICE |
Yes |
da2xxx |
Change to SVOL was received from RCU, PSUx -> SMPL |
DKC environment |
SERVICE |
Yes |
da3xxx |
Change to SVOL was received from RCU, COPY -> SMPL |
DKC environment |
SERVICE |
Yes |
da4xxx |
Change to SVOL was received from RCU, PAIR -> SMPL |
DKC environment |
SERVICE |
Yes |
da5xxx |
Change to SVOL was received from RCU, DELETING END |
DKC environment |
SERVICE |
Yes |
da6xxx |
Change to SVOL was received from RCU, HOLD -> SMPL |
DKC environment |
SERVICE |
Yes |
db0xxx |
Drive port temporary error (Drive path: Boundary 0) |
Drive |
SERVICE |
Yes |
db1xxx |
Drive port temporary error (Drive path: Boundary 0) |
Drive |
SERVICE |
Yes |
db2xxx |
Drive port temporary error (Drive path: Boundary 1) |
Drive |
SERVICE |
Yes |
db3xxx |
Drive port temporary error (Drive path: Boundary 1) |
Drive |
SERVICE |
Yes |
db4xxx |
Drive port blockade (Drive path: Boundary 0) |
Drive |
MODERATE |
Yes |
db5xxx |
Drive port blockade (Drive path: Boundary 0) |
Drive |
MODERATE |
Yes |
db6xxx |
Drive port blockade (Drive path: Boundary 1) |
Drive |
MODERATE |
Yes |
db7xxx |
Drive port blockade (Drive path: Boundary 1) |
Drive |
MODERATE |
Yes |
db8xxx |
LDEV blockade (Drive path: Boundary 0/Effect of Drive port blockade) |
Drive |
SERIOUS |
Yes |
db9xxx |
LDEV blockade (Drive path: Boundary 0/Effect of Drive port blockade) |
Drive |
SERIOUS |
Yes |
dbaxxx |
LDEV blockade (Drive path: Boundary 1/Effect of Drive port blockade) |
Drive |
SERIOUS |
Yes |
dbbxxx |
LDEV blockade (Drive path: Boundary 1/Effect of Drive port blockade) |
Drive |
SERIOUS |
Yes |
dbcxxx |
Drive Link Rate Abnormality (Drive path: Boundary 0) |
Drive |
SERVICE |
Yes |
dbdxxx |
Drive Link Rate Abnormality (Drive path: Boundary 0) |
Drive |
SERVICE |
Yes |
dbexxx |
Drive Link Rate Abnormality (Drive path: Boundary 1) |
Drive |
SERVICE |
Yes |
dbfxxx |
Drive Link Rate Abnormality (Drive path: Boundary 1) |
Drive |
SERVICE |
Yes |
dc0xxx |
Pair suspend(RIO path closed) |
DKC environment |
SERIOUS |
Yes |
dc1xxx |
Pair suspend(M-VOL error) |
DKC environment |
SERIOUS |
Yes |
dc2xxx |
Pair suspend(R-VOL error) |
DKC environment |
SERIOUS |
Yes |
dc4xxx |
Pair suspend(Suspend report) |
DKC environment |
SERIOUS |
Yes |
dc5xxx |
Pair suspend(Simplex report) |
DKC environment |
SERIOUS |
Yes |
dc6xxx |
Pair suspend(Communication error at RCU) |
DKC environment |
SERIOUS |
Yes |
dc7xxx |
Pair suspend(Error detected at RCU) |
DKC environment |
SERIOUS |
Yes |
dc8xxx |
Pair suspend(MCU P/S OFF) |
DKC environment |
SERVICE |
Yes |
dc9xxx |
Pair suspend(Delta volume error) |
DKC environment |
SERIOUS |
Yes |
dcaxxx |
Pair suspend(Spread by error of another affiliate) |
DKC environment |
SERIOUS |
Yes |
dce0xx |
UR M-JNL Meta overflow warning |
DKC environment |
MODERATE |
Yes |
dce1xx |
UR M-JNL Data overflow warning |
DKC environment |
MODERATE |
Yes |
dce2xx |
UR R-JNL Meta overflow warning |
DKC environment |
MODERATE |
Yes |
dce3xx |
UR R-JNL Data overflow warning |
DKC environment |
MODERATE |
Yes |
dcf0xx |
HUR read JNL was interrupted for 1 minute (at MCU) |
DKC environment |
MODERATE |
Yes |
dcf1xx |
HUR read JNL was interrupted for 5 minute (at MCU) |
DKC environment |
SERIOUS |
Yes |
dcf2xx |
HUR read JNL was interrupted for 1 minute (at RCU) |
DKC environment |
MODERATE |
Yes |
dcf3xx |
HUR read JNL was interrupted for 5 minute (at RCU) |
DKC environment |
SERIOUS |
Yes |
dcf4xx |
URxUR M-JNL Meta full Warning |
DKC environment |
MODERATE |
Yes |
dcf5xx |
URxUR M-JNL Data full Warning |
DKC environment |
MODERATE |
Yes |
dd0xxx |
GAD for this volume was suspended (Due to an unrecoverable failure on the remote copy connections) |
Failure with paired volumes |
SERIOUS |
Yes |
dd1xxx |
GAD for this volume was suspended (Due to a failure on the volume) |
Failure with paired volumes |
SERIOUS |
Yes |
dd2xxx |
GAD for this volume was suspended (Due to an internal error condition detected) |
Failure with paired volumes |
SERIOUS |
Yes |
dd3xxx |
Status of the P-VOL was not consistent with the S-VOL |
Failure with paired volumes |
SERIOUS |
Yes |
dee0xx |
Quorum Disk Restore |
Drive |
SERVICE |
Yes |
def0xx |
Quorum Disk Blocked |
Drive |
SERIOUS |
Yes |
dfexxx |
Response late Drive |
Drive |
SERVICE |
Yes |
eb0xxx |
Drive blockade (drive)(with redundancy) |
Drive |
SERIOUS |
Yes |
eb1xxx |
Drive blockade (drive)(with redundancy) |
Drive |
SERIOUS |
Yes |
eb2xxx |
Drive blockade (drive)(without redundancy) |
Drive |
SERIOUS |
Yes |
eb3xxx |
Drive blockade (drive)(without redundancy) |
Drive |
SERIOUS |
Yes |
eb4xxx |
Drive blockade(Effect of Dynamic sparing normal end) |
Drive |
SERVICE |
Yes |
eb5xxx |
Drive blockade(Effect of Dynamic sparing normal end) |
Drive |
SERVICE |
Yes |
eb6xxx |
Correction access occurred |
Drive |
SERIOUS |
Yes |
eb7xxx |
Correction access occurred |
Drive |
SERIOUS |
Yes |
eb8xxx |
Reboot stopped due to much write pending data |
Drive |
SERVICE |
Yes |
eb9xxx |
Reboot stopped due to much write pending data |
Drive |
SERVICE |
Yes |
ef4xxx |
Pinned slot |
Drive |
MODERATE |
Yes |
ef5xxx |
External VOL Write Error |
Drive |
MODERATE |
Yes |
ef8xxx |
LDEV blockade (Effect of drive blockade) |
Drive |
SERIOUS |
Yes |
efbxxx |
Drive temporary error |
Drive |
SERVICE |
Yes |
efd000 |
External storage system connection device blockade |
Drive |
SERIOUS |
Yes |
effbxx |
NSW failure |
DKC environment |
SERIOUS |
Yes |
effcxx | PCI cable connection error | DKC environment | MODERATE | Yes |
effdxx |
Expander failure |
DKC environment |
SERIOUS |
Yes |
effexx |
UNIT connection error |
DKC environment |
MODERATE |
Yes |
fe0000 |
Cache battery is being charged |
Cache |
SERIOUS |
Yes |
fe0100 |
Cache write through end at system startup |
Cache |
SERVICE |
Yes |
fe0200 |
Cache write through start at system startup |
Cache |
MODERATE |
Yes |
fe030x |
CFM type error or CFM shortage |
Cache |
SERIOUS |
Yes |
fe040x |
Mounting Battery shortage |
Battery |
SERIOUS |
Yes |
ff21xx |
LANB blocking |
DKC environment |
MODERATE |
Yes |
ff4xxx |
Pinned slot |
Cache |
MODERATE |
Yes |
ff5xxx |
External VOL Read Error |
Drive |
MODERATE |
Yes |
ffc30x |
Cache Package Blockade Processing end |
Cache |
SERVICE |
Yes |
ffcbxx |
CTL patrol check error |
DKC environment |
SERVICE |
No |
ffccxy |
CFM patrol check error |
Cache |
MODERATE |
Yes |
ffcd0x |
Area is volatilized |
Cache |
SERVICE |
Yes |
ffcfxx |
Module group is volatilized |
Cache |
SERVICE |
Yes |
ffd400 |
Hard implementation out of the definition |
DKC environment |
MODERATE |
Yes |
ffe20x |
SM area blocking |
SM |
SERIOUS |
Yes |
ffe40x |
Replace failed |
SM |
SERIOUS |
Yes |
ffe700 |
Shared memory is volatiled |
SM |
SERIOUS |
Yes |
ffe800 |
Definition/Installation mismatch |
Cache |
SERIOUS |
Yes |
ffea0x |
Recovery of area blocked temporarily was completed |
SM |
SERVICE |
Yes |
ffeb00 |
Configuration information restore by backup failed |
SM |
SERIOUS |
Yes |
ffee0x |
Area temporary blocking |
SM |
SERVICE |
Yes |
ffef00 |
Rebooted without volatilization |
SM |
SERVICE |
Yes |
fff0xx |
Cache correctable error |
Cache |
SERVICE |
Yes |
fff400 |
Area blocking |
Cache |
SERIOUS |
Yes |
fff50x |
Both area failed |
Cache |
MODERATE |
Yes |
fff7xx |
GUM blocking |
DKC environment |
MODERATE |
Yes |
fff90x |
Replace failed |
Cache |
SERVICE |
Yes |
fffaxx |
Battery warning |
Battery |
MODERATE |
Yes |
fffexx |
Warning for forcible volatile mode |
DKC environment |
MODERATE |
Yes |
Legend:
Notes:
|