[Remote Replication] Edit Pair Options

Audit Log User Guide for VSP E Series

Version
93-06-8x
Audience
anonymous
Part Number
MK-97HM85024-17

Detailed Information 1

Item

Description

Copy Type

The program product name for this operation

TC: TrueCopy

P-VOL(Port-G-ID-LUN)

The port number, host group number, and LUN of the primary volume of a pair that uses a volume connected to the host using Fibre Channel or iSCSI

Fence Level

The changed fence level setting (the condition that MCU rejects the write operation to the primary volume).

Never: Can write to the primary volume even when the pair is split.

Data: Cannot write to the primary volume when update copying fails.

Status: Cannot write to the primary volume, only when the storage system of the primary site cannot change the pair status of the secondary volume to PSUE.

VOL(LDKC:CU:LDEV)

The LDKC number, CU number, and LDEV number of the volume (on the local storage system) of a pair that uses a volume connected to the host using NVMe over FC

Result

The result of the operation

Normal end: Normal end,

Error(xxxx-yyyyy): Abnormal end

where xxxx: Part code, yyyyy: Error code

Num. of Pairs

The number of pairs on which the setting is changed

Detailed Information 2

Item

Description

Copy Type

The program product name for this operation

UR: Universal Replicator

P-VOL(Port-G-ID-LUN)

The port number, host group number, and LUN of the primary data volume of a pair that uses a volume connected to the host using Fibre Channel or iSCSI

S-VOL(Port-G-ID-LUN)

The port number, host group number, and LUN of the secondary data volume of a pair that uses a volume connected to the host using Fibre Channel or iSCSI

MirrorID

The mirror ID

M-JNL

The master journal number

R-JNL

The restore journal number

Error Level

Range of the pair split at failure occurrence

Mirror: When a pair fails, all the pairs are split that exist in the same mirror as the pair.

LU: When a pair fails, only the pair is split.

P-VOL(LDKC:CU:LDEV)

The LDKC number, CU number, and LDEV number of the primary data volume of a pair that uses a volume connected to the host using NVMe over FC

S-VOL(LDKC:CU:LDEV)

The LDKC number, CU number, and LDEV number of the secondary data volume of the pair that uses a volume connected to the host using NVMe over FC

Result

The result of the operation

Normal end: Normal end,

Error(xxxx-yyyyy): Abnormal end

where xxxx: Part code, yyyyy: Error code

Num. of Pairs

The number of pairs on which the setting is changed

Example 1: Copy type is TC

RMI AP,,[Remote Replication],Edit Pair Options,,Normal end,
Seq.=xxxxxxxxxx
+Copy Type=TC,{P-VOL(Port-G-ID-LUN),Fence Level,VOL(LDKC:CU:LDEV),
Result}=
[{1A-0x00-0,Never,Normal end},{1A-0x00-1,Never,-,Normal end},
{1A-0x00-2,Never,-,Normal end},(Snip)-(Snip)],Num. of Pairs=xx

Example 2: Copy type is UR

RMI AP,,[Remote Replication],Edit Pair Options,,Normal end,
Seq.=xxxxxxxxxx
+Copy Type=UR
+{P-VOL(Port-G-ID-LUN),S-VOL(Port-G-ID-LUN),MirrorID,M-JNL,R-JNL,
Error Level,P-VOL(LDKC:CU:LDEV),S-VOL(LDKC:CU:LDEV),Result}=
[{4C-0x00-0,4A-0x00-0,0x00,0x001,0x001,Mirror,-,Normal end},
{4C-0x00-1,4A-0x00-1,0x00,0x001,0x001,Mirror,-,Normal end}],
Num. of Pairs=2