[Maintenance] Install

Audit Log User Guide for VSP E Series

Version
93-06-8x
Audience
anonymous
Part Number
MK-97HM85024-17

Detailed Information 1

Item

Description

Shared Memory Function

Names of the shared memories (all the mounted shared memories including installed shared memories)

Detailed Information 2

Item

Description

Location

Mounted position of the installed CHB or DKB (CHB-xx or DKB-xx)

Type

Type of the part of the installed CHB or DKB

Forcibly run without safety checks

Indicates whether the forcible installation function without safety checks is enabled or disabled.

However, a hyphen (-) is output except when a user with the Support Personnel role operates from the MPC.

Detailed Information 3

Item

Description

Module Type

Type of the installed module

Outputs Channel Board Box as a fixed parameter.

Location

Mounted position of the installed PECB (PECB-xx)

Num of PECBs

The number of the installed PECBs

Expansion Mode

The expansion mode (1:2)

Forcibly run without safety checks

Indicates whether the forcible installation function without safety checks is enabled or disabled.

However, a hyphen (-) is output except when a user with the Support Personnel role operates from the MPC.

Detailed Information 4

Item

Description

Location

Mounted position of the installed drive box (DB-xx or DB-xx&xx)

Type

Type of the part of the installed drive box

Num of Drive Boxes

Number of the installed drive boxes

Forcibly run without safety checks

Indicates whether the forcible installation function without safety checks is enabled or disabled.

However, a hyphen (-) is output except when a user with the Support Personnel role operates from the MPC.

Detailed Information 5

Item

Description

Drives

Mounted position of the installed drive

Num of Drives

Number of the installed drives

Forcibly run without safety checks

Indicates whether the forcible installation function without safety checks is enabled or disabled.

However, a hyphen (-) is output except when a user with the Support Personnel role operates from the MPC.

Detailed Information 6

Item

Description

Location

Mounted position of the installed HFB (CHB-1A/1B/1C/1D or CHB-2A/2B/2C/2D)

Forcibly run without safety checks

Indicates whether the forcible installation function without safety checks is enabled or disabled.

However, a hyphen (-) is output except when a user with the Support Personnel role operates from the MPC.

Example 1: Installing SMs

GUM,,[Maintenance],Install,,Normal end,Seq.=xxxxxxxxxx
+Shared Memory Function=[xxxxxxxx,xxxxxxxx]

Example 2: Installing CHBs or DKBs

GUM,,[Maintenance],Install,,Normal end,Seq.=xxxxxxxxxx
+Location=[xxx,xxx],Type=xxxx,
Forcibly run without safety checks=Enable

Example 3: Installing channel board boxes

GUM,,[Maintenance],Install,,Normal end,Seq.=xxxxxxxxxx
+Module Type=Channel Board Box,
Location=[PECB-xx,PECB-xx,PECB-xx,PECB-xx],
Num of PECBs=4,Expansion Mode=1:2,
Forcibly run without safety checks=Enable

Example 4: Installing drive boxes

GUM,,[Maintenance],Install,,Normal end,Seq.=xxxxxxxxxx
+{Location,Type}=[{DB-xx,xxx},{DB-xx,xxx},{DB-xx,xxx}],
Num of Drive Boxes=3,
Forcibly run without safety checks=Enable

Example 5: Installing drives

GUM,,[Maintenance],Install,,Normal end,Seq.=xxxxxxxxxx
+Drives=[HDDxx-xx,HDDxx-xx,HDDxx-xx],Num of Drives=3,
Forcibly run without safety checks=Enable

Example 6: Installing HFBs

GUM,,[Maintenance],Install,,Normal end,Seq.=xxxxxxxxxx
+Location=[CHB-1A/1B/1C/1D,CHB-2A/2B/2C/2D],