[Maintenance] Block(Type Change)

Audit Log User Guide for VSP E Series

Version
93-06-8x
Audience
anonymous
Part Number
MK-97HM85024-17

Detailed Information 1

Item

Description

Location

Mounted position of the CTL (CTLx) to be blocked

Forcibly run without safety checks

Indicates whether the function to forcibly change the type without safety checks is enabled or disabled.

However, a hyphen (-) is output except when a user with the Support Personnel role operates from the MPC.

Detailed Information 2

Item

Description

Cache Size

Cache size of the blocked cache memory

Forcibly run without safety checks

Indicates whether the function to forcibly change the type without safety checks is enabled or disabled.

However, a hyphen (-) is output except when a user with the Support Personnel role operates from the MPC.

Detailed Information 3

Item

Description

Location

Mounted position of the DKB (DKB-xx) to be blocked

Forcibly block

Indicates whether the function to forcibly block the DKB is enabled or disabled*

Type

Type of the part of the DKB to be blocked

Forcibly run without safety checks

Indicates whether the function to forcibly change the type without safety checks is enabled or disabled*

* A hyphen (-) is output except when a user with the Support Personnel role operates from the MPC.

Detailed Information 4

Item

Description

Location

Mounted position of the CHB (CHB-xx) to be blocked

Forcibly block

Indicates whether the function to forcibly block the CHB is enabled or disabled*

Type

Type of the part of the CHB to be blocked

Forcibly run without safety checks

Indicates whether the function to forcibly change the type without safety checks is enabled or disabled*

* A hyphen (-) is output except when a user with the Support Personnel role operates from the MPC.

Detailed Information 5

Item

Description

Location

Mounted position of the ACLF or BKMF (BKMF-xx) to be blocked

Type

Type of the part of the ACLF or BKMF to be blocked

Forcibly run without safety checks

Indicates whether the function to forcibly replace the part without safety checks is enabled or disabled*

* A hyphen (-) is output except when a user with the Support Personnel role operates from the MPC.

Example 1: Blocking CTLs along with CTL type change when replacing

GUM,,[Maintenance],Block(Type Change),,Normal end,Seq.=xxxxxxxxxx
+Location=xxx,Forcibly run without safety checks=Enable

Example 2: Blocking CMs along with CM type change when replacing

GUM,,[Maintenance],Block(Type Change),,Normal end,Seq.=xxxxxxxxxx
+Cache Size=xxxxxxxx,Forcibly run without safety checks=Enable

Example 3: Blocking DKBs along with DKB type change when replacing

GUM,,[Maintenance],Block(Type Change),,Normal end,Seq.=xxxxxxxxxx
+Location=xxx,Forcibly block=Disable,Type=xxxxxx,
Forcibly run without safety checks=Enable

Example 4: Blocking CHBs along with CHB type change when replacing

GUM,,[Maintenance],Block(Type Change),,Normal end,Seq.=xxxxxxxxxx
+Location=CHB-xx,Forcibly block=Disable,Type=xxxxxx,
Forcibly run without safety checks=Disable

Example 5: Blocking ACLFs or BKMFs along with ACLF or BKMF type change when replacing

GUM,,[Maintenance],Block(Type Change),,Normal end,Seq.=xxxxxxxxxx
+Location=xxx,Type=Backup Module,Forcibly run without safety
checks=Disable