[Information] Threshold Value

Audit Log User Guide for VSP E Series

Version
93-06-8x
Audience
anonymous
Part Number
MK-97HM85024-17

Basic Information

Parameter

Description

Alter

Change the threshold of failed PDEV (physical device).

Error Reset

Indicates Error Reset.

Detailed Information

Item

Description

Type

The period of time to acquire the result of threshold diagnosis using the read diagnosis function.

7days: 7 days, Total: Every operating days

Mechanical error (Recovered, Unrecd.)

The threshold of the Mechanical error

Media error (Recovered, Unrecd.)

The threshold of the Media error

Read/Write error (Recovered, Unrecd.)

The threshold of the Read/Write error

Drive I/F error (Recovered, Unrecd.)

The threshold of the Drive I/F error

Controller hardware error (Recovered, Unrecd.)

The threshold of the Controller hardware error

Drive response late

The threshold of the Drive response late

SAS I/F error Port 0 (Unrecd.)

The threshold of the SAS I/F error Port 0

SAS I/F error Port 1 (Unrecd.)

The threshold of the SAS I/F error Port 1

Port 0 error (Unrecd.)

The threshold of the Port 0 error

Port 1 error (Unrecd.)

The threshold of the Port 1 error

PDEV

The mounting location of PDEV (physical device) that is the target of Alter or error reset

Num. of PDEVs

The number of PDEVs (physical devices)

Example 1: Changing the threshold

MPC,,[Information],Threshold Value,Alter,Normal end,
Seq.=xxxxxxxxxx
+Type=7days
+{Mechanical error(Recovered,Unrecd.),Media error(Recovered,
Unrecd.),Read/Write error(Recovered,Unrecd.),
Drive I/F error(Recovered,Unrecd.),
Controller hardware error(Recovered,Unrecd.),
Drive response late,SAS I/F error Port 0(Unrecd.),
SAS I/F error Port 1(Unrecd.),Port 0 error(Unrecd.),
Port 1 error(Unrecd.)}
={(150,60),(0,15),(150,30),(150,6),(150,6),0,6,6,12,12}
++PDEV=[HDD000-01,HDD000-02],Num. of PDEVs=2

Example 2: Error Reset

MPC,,[Information],Threshold Value,Error Reset,Normal end,
Seq.=xxxxxxxxxx
+PDEV=HDD000-01