Add External iSCSI Name/Modify External CHAP User

Audit Log User Guide for VSP E Series

Version
93-06-8x
Audience
anonymous
Part Number
MK-97HM85024-17

Example

Out-of-band,,[Config Command],,,Accept,Seq.=xxxxxxxxxx
+Command=Add External iSCSI Name/Modify External CHAP User
++Port=3B,iSCSI Name=iqn.1994-04.jp.co.hitachi:rsd.h8h.t.00001.4b000,
TCP Port=3260,IP Address=192.168.0.169,CHAP User=user1,
User Auth Switch=Enable,Auth Mode=Unidirectional,iSCSI Virtual Port ID=15

Detailed Information

Item

Description

Command

The command name

Port

The name of the port to which the iSCSI initiator belongs

iSCSI Name

The iSCSI name

TCP Port

The TCP port number

If this item is not specified by the command option, the TCP port number of the iSCSI target on the port is output.

IP Address

The IP address of the port on the external system

CHAP User

The CHAP user name to be set for Secret

When the iSCSI name of the external storage system is added, a hyphen (-) is output.

User Auth Switch

The setting status of CHAP authentication

Enable: CHAP authentication is enabled.

Disable: CHAP authentication is disabled.

When the iSCSI name of the external storage system is changed, a hyphen (-) is output.

Auth Mode

The CHAP authentication mode

Unidirectional: One-way CHAP authentication

Mutual: Mutual-way CHAP authentication

When the iSCSI name of the external storage system is changed, a hyphen (-) is output.

iSCSI Virtual Port ID

The iSCSI virtual port ID (0-15)

No value is output when the option is not specified.