raidcom get drive

Storage Advisor Embedded User Guide

Version
93-07-2x
88-08-12
Audience
anonymous
Part Number
MK-97HM85022-25
Supported storage systems:
  • VSP 5000 series
  • VSP G130, G/F350, G/F370, G/F700, G/F900

Displays drive information.

Syntax

raidcom get drive [-parity_grp_id <gno-sgno> | -usage <usage>]

Options and parameters

-parity_grp_id <gno-sgno>

Specifies the parity group number (gno: 1 to 52, sgno: 1 to 32)

Example:

3-1

-usage <usage>

Specifies the drive usage.

Specify the following character strings for <usage>:

  • data: Data drive
  • spare: Spare drive
  • free: Unused drive

Example

Displaying drive information.

#raidcom get drive
LOCATION	TYPE	RPM	TOTAL_CAP(GB)	CODE		USAGE	STS	GROUP
1-1		SAS	15000		300	DKS5C-K300SS	DATA	NML	1-1

Description of the raidcom get drive output:

LOCATION

Displays the location of the drive in the xx-yy format. In Device Manager - Storage Navigator, the drive location is displayed in the HDDxx-yy format.

TYPE

Displays the drive type.

(VSP 5000 series) SSD or SCM is displayed as a drive type of a drive whose drive type code (CODE) is SPx5x-YxxxNC, where x is any character string or number. The displayed character string depends on the DKCMAIN microcode version.

RPM

Displays the number of revolutions of a drive in rpm. For SSD, a hyphen (-) is displayed.

TOTAL_CAP(GB)

Displays the capacity of a drive in gigabytes.

CODE

Displays the drive type code.

USAGE

Displays the drive usage.

  • DATA: Data drive
  • SPARE: Spare drive
  • FREE: Unused drive
STS

Displays the drive status.

  • NML: Normal.
  • WAR: A blocked part exists.
  • CPY: Drive copy is in process.
  • CPI: Copy is incomplete.
  • RSV: Spare disk is unusable.
  • FAI: Blocked due to a failure.
  • BLK: Blocked due to maintenance.
  • UNK: The status is unknown.
GROUP

Displays the parity group number of the drive if it is contained in a parity group. If the drive is not contained in a parity group, a hyphen (-) is displayed.