- VSP 5000 series
- VSP G130, G/F350, G/F370, G/F700, G/F900
Displays drive information.
Syntax
raidcom get drive [-parity_grp_id <gno-sgno> | -usage <usage>]
Options and parameters
Example
Displaying drive information.
#raidcom get drive
LOCATION TYPE RPM TOTAL_CAP(GB) CODE USAGE STS GROUP 1-1 SAS 15000 300 DKS5C-K300SS DATA NML 1-1
Description of the raidcom get drive output:
- LOCATION
-
Displays the location of the drive in the xx-yy format. In Device Manager - Storage Navigator, the drive location is displayed in the HDDxx-yy format.
- TYPE
-
Displays the drive type.
(VSP 5000 series) SSD or SCM is displayed as a drive type of a drive whose drive type code (CODE) is SPx5x-YxxxNC, where x is any character string or number. The displayed character string depends on the DKCMAIN microcode version.
- RPM
-
Displays the number of revolutions of a drive in rpm. For SSD, a hyphen (-) is displayed.
- TOTAL_CAP(GB)
-
Displays the capacity of a drive in gigabytes.
- CODE
-
Displays the drive type code.
- USAGE
-
Displays the drive usage.
- DATA: Data drive
- SPARE: Spare drive
- FREE: Unused drive
- STS
-
Displays the drive status.
- NML: Normal.
- WAR: A blocked part exists.
- CPY: Drive copy is in process.
- CPI: Copy is incomplete.
- RSV: Spare disk is unusable.
- FAI: Blocked due to a failure.
- BLK: Blocked due to maintenance.
- UNK: The status is unknown.
- GROUP
-