Power Consumption report

System Administrator Guide for VSP E990 and VSP G130, G/F350, G/F370, G/F700, G/F900

Version
88-08-0x
Audience
anonymous
Part Number
MK-97HM85028-11

The following figure shows an example of a power consumption report. A record is created every two hours for each power consumption and temperature monitoring data. The table following the figure describes the items in the report.

No records are created if the storage system is turned off. If the system is in maintenance mode or the SVP is rebooted, up to two hours of records could be lost.

If a failure occurs in the storage system, the correct information might not be output.

A hyphen(-) is displayed if the power and temperature information cannot be acquired due to a unit or network failure.



Item

Description

Power Consumption Average (W)

Average of the power consumption

Power Consumption Maximum (W)

Maximum of the power consumption

Power Consumption Minimum (W)

Minimum of the power consumption

TEMP:HSNBX0-HSNPANEL0 Average (degrees C) Average temperature of HSNBX0:HSNPANEL0
TEMP:HSNBX0-HSNPANEL0 Maximum (degrees C) Maximum temperature of HSNBX0:HSNPANEL0
TEMP:HSNBX0-HSNPANEL0 Minimum (degrees C) Minimum temperature of HSNBX0:HSNPANEL0
TEMP:HSNBX1-HSNPANEL1 Average (degrees C) Average temperature of HSNBX1:HSNPANEL1
TEMP:HSNBX1-HSNPANEL1 Maximum (degrees C) Maximum temperature of HSNBX1:HSNPANEL1
TEMP:HSNBX1-HSNPANEL1 Minimum (degrees C) Minimum temperature of HSNBX1:HSNPANEL1

TEMP:DKC0-Cluster1 Average (degrees C)

Average temperature of DKC0:CL1

TEMP:DKC0-Cluster1 Maximum (degrees C)

Maximum temperature of DKC0:CL1

TEMP:DKC0-Cluster1 Minimum (degrees C)

Minimum temperature of DKC0:CL1

TEMP:DKC0-Cluster2 Average (degrees C)

Average temperature of DKC0:CL2

TEMP:DKC0-Cluster2 Maximum (degrees C)

Maximum temperature of DKC0:CL2

TEMP:DKC0-Cluster2 Minimum (degrees C)

Minimum temperature of DKC0:CL2

Table. Power Consumption report

Item

Description

TEMP:DB00-DBPS00-1 Average (Temperature in degrees C)

TEMP:DB00-DBPS00-1 Maximum (Temperature in degrees C),

TEMP:DB00-DBPS00-1 Minimum (Temperature in degrees C),

TEMP:DB00-DBPS00-2 Average (Temperature in degrees C),

TEMP:DB00-DBPS00-2 Maximum (Temperature in degrees C),

TEMP:DB00-DBPS00-2 Minimum (Temperature in degrees C)

Average temperature, maximum temperature, and minimum temperature of the DB for the two-hour period. Outputs in the following format:

TEMP:DB XX -DBPS XX -CL Average, Maximum, or Minimum (Temperature in degrees Celsius)

  • XX: DB number

00 to 07 (VSP F350, VSP G350)

00 to 11 (VSP F370, VSP G370)

00 to 47 (VSP F700, VSP F900, VSP G700, VSP G900)

00 to 03 (VSP E990)

  • CL: Cluster number (1 or 2)