[SPM] Update Port WWN

Audit Log User Guide for VSP E Series and VSP G130, G/F350, G/F370, G/F700, G/F900

Version
88-07-0x
Audience
anonymous
Part Number
MK-97HM85024-10

Detailed Information

Item

Description

Mode

An executed operation

Add WWN: Added a WWN (an HBA is monitored).

Delete WWN: Deleted a WWN (an HBA is not monitored).

WWN

An added or deleted WWN

A WWN is a 16-digit number in the hexadecimal format.

SPM Name

AnSPM name for an added or deleted HBA

Priority

An attribute specified to the HBA

Prio: a prioritized WWN

Non-Prio: a non-prioritized WWN

This information is output only when a WWN (HBA) is added.

Port

A name of the port where the HBA is added

Num. of Ports

The number of ports where the HBA is added

Num. of WWNs

The number of added or deleted WWNs

Example

RMI AP,,[SPM],Update Port WWN,,Normal end,
Seq.=xxxxxxxxxx
+{Mode,WWN,SPM Name,Priority}
={Add WWN,0xXXXXXXXXXXXXXXXX,XXXXXXXXXXXXXXXX,Non-Prio},
++Port=[1A,3A],Num. of Ports=2,
-Num. of WWNs=1