[Remote Replication] Edit Pair Options

Audit Log User Guide for VSP E Series and VSP G130, G/F350, G/F370, G/F700, G/F900

Version
88-07-0x
Audience
anonymous
Part Number
MK-97HM85024-10

Detailed Information 1

Item

Description

Copy Type

The program product name for this operation

TC: TrueCopy

P-VOL(Port-G-ID-LUN)

The port number, host group number, and LUN of the primary volume

Fence Level

The changed fence level setting (the condition that MCU rejects the write operation to the primary volume).

Never: Can write to the primary volume even when the pair is split.

Data: Cannot write to the primary volume when update copying fails.

Status: Cannot write to the primary volume, only when the storage system of the primary site cannot change the pair status of the secondary volume to PSUE.

Result

The result of the operation

Normal end: Normal end,

Error(xxxx-yyyyy): Abnormal end

where xxxx: Part code, yyyyy: Error code

Num. of Pairs

The number of pairs on which the setting is changed

Detailed Information 2

Item

Description

Copy Type

The program product name for this operation

UR: Universal Replicator

P-VOL(Port-G-ID-LUN)

The port number, host group number, and LUN of the primary data volume

S-VOL(Port-G-ID-LUN)

The port number, host group number, and LUN of the secondary data volume

MirrorID

The mirror ID

M-JNL

The master journal number

R-JNL

The restore journal number

Error Level

Range of the pair split at failure occurrence

Mirror: When a pair fails, all the pairs are split that exist in the same mirror as the pair.

LU: When a pair fails, only the pair is split.

Result

The result of the operation

Normal end: Normal end,

Error(xxxx-yyyyy): Abnormal end

where xxxx: Part code, yyyyy: Error code

Num. of Pairs

The number of pairs on which the setting is changed

Example 1: Copy type is TC

RMI AP,,[Remote Replication],Edit Pair Options,,Normal end,
Seq.=xxxxxxxxxx
+Copy Type=TC,{P-VOL(Port-G-ID-LUN),Fence Level,Result}
=[{1A-0x00-0,Never,Normal end},{1A-0x00-1,Never,Normal end},
{1A-0x00-2,Never,Normal end},(Snip)-(Snip)],
Num. of Pairs=xx

Example 2: when the copy type is UR

RMI AP,,[Remote Replication],Edit Pair Options,,Normal end,
Seq.=xxxxxxxxxx
+Copy Type=UR
+{P-VOL(Port-G-ID-LUN),S-VOL(Port-G-ID-LUN),MirrorID,
M-JNL,R-JNL,Error Level,Result}
=[{4C-0x00-0,4A-0x00-0,0x00,0x001,0x001,Mirror,Normal end},
{4C-0x00-1,4A-0x00-1,0x00,0x001,0x001,Mirror,Normal end}],
Num. of Pairs=2