[Remote Replication] Edit Options

Audit Log User Guide for VSP E Series and VSP G130, G/F350, G/F370, G/F700, G/F900

Version
88-07-0x
Audience
anonymous
Part Number
MK-97HM85024-10

Detailed Information for Example 1- 4

Item

Description

Copy Type

The program product name for this operation

TC: TrueCopy

Max Initial Copy

The maximum number of initial copy operations set

If this is not a subject to change, a hyphen (-) is displayed. If any one of Max Initial Copy, CU Activity, Path Blockade Watch(s), and Path Blockade SIM Watch(s) is changed, this will be the subject to change.

CU Activity

Indicates whether the parallel operation of initial copy by the control unit is enabled or not.

Enable or Disable will appear.

If this is not a subject to change, a hyphen (-) is displayed. If any one of Max Initial Copy, CU Activity, Path Blockade Watch(s, and Path Blockade SIM Watch(s) is changed, this will be the subject to change.

Path Blockade Watch(s)

The path blockade watch period setting (in seconds).

If this is not a subject to change, a hyphen (-) is displayed. If any one of Max Initial Copy, CU Activity, Path Blockade Watch(s, and Path Blockade SIM Watch(s) is changed, this will be the subject to change.

Path Blockade SIM Watch(s)

The path blockade SIM watch period setting (in seconds).

If this is not a subject to change, a hyphen (-) is displayed. If any one of Max Initial Copy, CU Activity, Path Blockade Watch(s, and Path Blockade SIM Watch(s) is changed, this will be the subject to change.

Switch

Indicates the ON/OFF information of each bit of the function switch that is allocated in the 64 bit format; the first digit corresponds to the bit 0 while the last one corresponds to the bit 63.

0: OFF, 1: ON

If this is not a subject to change, a hyphen (-) is displayed.

LDKC

The LDKC number

CU

The CU number of the connected CU

Max Initial Copy

The number of parallel operation of initial copy by CU.

If this is not a subject to change, a hyphen (-) is displayed.

Num. of CUs

The number of CUs set

Detailed Information 5

Item

Description

Copy Type

The program product name for this operation

UR: Universal Replicator

Max Initial Copy

The maximum number of initial copy operations set

Detailed Information 6

Item

Description

Copy Type

The program product name for this operation

GAD: global-active device

Max Initial Copy

The setting of the maximum number of initial copy operations

Path Blockade Watch(s)

The path blockade watch period setting (in seconds).

Path Blockade SIM Watch(s)

The path blockade SIM watch period setting (in seconds).

Service SIM

Indicates whether the remote replication related SIM is reported.

Report: Reported, Not Report: Not reported

Switch

Indicates the ON/OFF information of each bit of the function switch that is allocated in the 64 bit format; the first digit corresponds to the bit 0 while the last one corresponds to the bit 63.

0: OFF, 1: ON

If this is not a subject to change, a hyphen (-) is displayed.

Max Initial Copy HA

The setting of the number of initial copy operations of GAD

Example 1: Editing storage system options when the copy type is TC

RMI AP,,[Remote Replication],Edit Options,,Normal end,Seq.=xxxxxxxxxx
+Copy Type=TC,
{Max Initial Copy,CU Activity,Path Blockade Watch(s),
Path Blockade SIM Watch(s),Switch}
={128,Enable,45,070,-}

Example 2: Editing CU options when the copy type is TC

RMI AP,,[Remote Replication],Edit Options,,Normal end,Seq.=xxxxxxxxxx
+Copy Type=TC,{LDKC,CU,Max Initial Copy}
=[{0x00,0x00,04},{0x00,0x01,04},
{0x00,0x02,04},{0x00,0x03,04},
{0x00,0x04,04},(Snip)-(Snip)],Num. of CUs=255

Example 3: Editing both storage system options and CU options when the copy type is TC

RMI AP,,[Remote Replication],Edit Options,,Normal end,Seq.=xxxxxxxxxx
+Copy Type=TC,
{Max Initial Copy,CU Activity,Path Blockade Watch(s),
Path Blockade SIM Watch(s),Switch}
={128,Enable,45,070,-}
+{LDKC,CU,Max Initial Copy}
=[{0x00,0x00,04},{0x00,0x01,04},
{0x00,0x02,04},{0x00,0x03,04},
{0x00,0x04,04},(Snip)-(Snip)],Num. of CUs=255

Example 4: Editing remote replication function switch when the copy type is TC

RMI AP,,[Remote Replication],Edit Options,,Normal end,Seq.=xxxxxxxxxx
+Copy Type=TC,
{Max Initial Copy,CU Activity,Path Blockade Watch(s),
Path Blockade SIM Watch(s),Switch}
={-,-,-,-,1000 0000 0000 0000 0100 0000 0000 0000 0000 
0000 0000 0000 0000 0000 0000 0000}

Example 5: Copy type is UR

RMI AP,,[Remote Replication],Edit Options,,Normal end,Seq.=xxxxxxxxxx
+Copy Type=UR
+Max Initial Copy=64

Example 6: when the copy type is GAD

RMI AP,,[Remote Replication],Edit Options,,Normal end,Seq.=xxxxxxxxxx
+Copy Type=GAD,{Max Initial Copy,Path Blockade Watch(s),
Path Blockade SIM Watch(s),Service SIM,Switch,Max Initial Copy HA}=
{128,45,70,Not Report,0000 0000 0000 0000 0000 0000 0000 0000 0000 
0000 0000 0000 0000 0000 0000 0000,50}