Detailed Information
Item |
Description |
---|---|
S/N |
The serial number of the RCU |
MCU LDKC |
The LDKC number of the connected LDKC |
RCU LDKC |
The LDKC number of the paired LDKC |
Path Gr.ID |
The path group ID. When the path group ID is default setting, "Default" is output. |
Controller ID |
The controller ID of the RCU 7: VSP G1000/G1500 and VSP F1500, 8: VSP 5000 series, 18: VSP E series, VSP G130, G/F350, G/F370, G/F700, G/F900, VSP G200, G400, G600, G800, and VSP F400, F600, F800, 19: HUS VM |
Result |
The result of the operation Normal end: Normal end, Error(xxxx-yyyyy): Abnormal end where xxxx: Part code, yyyyy: Error code |
MCU Port |
The port number of MCU |
RCU Port |
The port number of RCU |
Num. of Port Pairs |
Number of pairs of the port to be operated |
Num. of RCUs |
The number of RCUs set |
Example
RMI AP,,[Remote Replication],Add Path,,Normal end, Seq.=xxxxxxxxxx +{S/N,MCU LDKC,RCU LDKC,Path Gr.ID,Controller ID,Result} ={411111,0x00,0x00,Default,18,Normal end} ++{MCU Port,RCU Port} =[{1E,3E},{5E,7E},{1F,3F},{5F,7F},{1G,3G},{5G,7G},{1H,3H}], Num. of Port Pairs=7 (Snip) +{S/N,MCU LDKC,RCU LDKC,Path Gr.ID,Controller ID,Result} ={422222,0x00,0x00,Default,18,Normal end} ++{MCU Port,RCU Port} =[{1E,3E},{5E,7E},{1F,3F},{5F,7F},{1G,3G},{5G,7G},{1H,3H}], Num. of Port Pairs=7 +Num. of RCUs=xx