Basic Information
Parameter |
Description |
---|---|
Alter |
Change the threshold of ORM (Online Read Margin) |
Error Reset |
Indicates Error Reset |
Detailed Information
Item |
Description |
---|---|
Type |
The period of time to acquire the result of threshold diagnosis using the read diagnosis function Today: Current day only, 7days: 7 days, Total: Every operating days |
Read Err. (Unrecovered) |
The threshold of the Read Error (Unrecovered) |
Read Err. (Recovered) |
The threshold of the Read Error (Recovered) |
Seek Err. (Recovered) |
The threshold of the Seek Error (Recovered) |
Seek Err. (Unrecovered) |
The threshold of the Seek Error (Unrecovered) |
Not Ready |
The threshold of the Not Ready status. |
Other Errors |
The threshold of Other Errors. |
Total Defect Count |
The threshold of the Total Defect Count |
Used Endurance Indicator |
The threshold of the Used Endurance Indicator |
Reboot Error |
The threshold of the Reboot Error |
DMA Error |
The threshold of the DMA Error |
Memory Error |
The threshold of the Memory Error |
Uncorrected Error |
The threshold of the Uncorrected Error |
Capacitor Error |
The threshold of the Capacitor Error |
PDEV |
The mounting location of the PDEV (physical device) that is the target of Alter or error reset |
Num. of PDEVs |
The number of PDEVs (physical devices) |
Example 1: Changing the threshold of SAS
MPC,,[Information],ORM Value,Alter,Normal end,Seq.=xxxxxxxxxx +Type=7days +{Read Err.(Unrecovered),Read Err.(Recovered), Seek Err.(Recovered),Seek Err.(Unrecovered),Not Ready, Other Errors}={15,1.00e-008,100,10,10,10} ++PDEV=[HDD000-01,HDD000-02],Num. of PDEVs=2
Example 2: Changing the threshold of the SSD when drive type is other than SLxxx-MxxxSS
MPC,,[Information],ORM Value,Alter,Normal end,Seq.=xxxxxxxxxx +Type=Total +{Total Defect Count}={15} ++PDEV=[HDD000-01,HDD000-02],Num. of PDEVs=2
Example 3: Changing the threshold of the SSD when drive type is SLxxx-MxxxSS
MPC,,[Information],ORM Value,Alter,Normal end,Seq.=xxxxxxxxxx +Type=Total +{Total Defect Count,Used Endurance Indicator}={160000,(99,90)} ++PDEV=[HDD000-03],Num. of PDEVs=1
Example 4: Changing the threshold of the FMD when drive type is NFHxx-Qxxxxx
MPC,,[Information],ORM Value,Alter,Normal end,Seq.=xxxxxxxxxx +Type=Today +{Total Defect Count,Reboot Error,DMA Error,Memory Error, Uncorrected Error,Used Endurance Indicator,Capacitor Error}= {0,2,10,500,512,(0,0),1} ++PDEV=[HDD000-03],Num. of PDEVs=1
Example 5: Error Reset
MPC,,[Information],ORM Value,Error Reset,Normal end, Seq.=xxxxxxxxxx +PDEV=HDD000-01