[Information] ORM Value

Audit Log User Guide for VSP E Series and VSP G130, G/F350, G/F370, G/F700, G/F900

Version
88-07-0x
Audience
anonymous
Part Number
MK-97HM85024-10

Basic Information

Parameter

Description

Alter

Change the threshold of ORM (Online Read Margin)

Error Reset

Indicates Error Reset

Detailed Information

Item

Description

Type

The period of time to acquire the result of threshold diagnosis using the read diagnosis function

Today: Current day only, 7days: 7 days, Total: Every operating days

Read Err. (Unrecovered)

The threshold of the Read Error (Unrecovered)

Read Err. (Recovered)

The threshold of the Read Error (Recovered)

Seek Err. (Recovered)

The threshold of the Seek Error (Recovered)

Seek Err. (Unrecovered)

The threshold of the Seek Error (Unrecovered)

Not Ready

The threshold of the Not Ready status.

Other Errors

The threshold of Other Errors.

Total Defect Count

The threshold of the Total Defect Count

Used Endurance Indicator

The threshold of the Used Endurance Indicator

Reboot Error

The threshold of the Reboot Error

DMA Error

The threshold of the DMA Error

Memory Error

The threshold of the Memory Error

Uncorrected Error

The threshold of the Uncorrected Error

Capacitor Error

The threshold of the Capacitor Error

PDEV

The mounting location of the PDEV (physical device) that is the target of Alter or error reset

Num. of PDEVs

The number of PDEVs (physical devices)

Example 1: Changing the threshold of SAS

MPC,,[Information],ORM Value,Alter,Normal end,Seq.=xxxxxxxxxx
+Type=7days
+{Read Err.(Unrecovered),Read Err.(Recovered),
Seek Err.(Recovered),Seek Err.(Unrecovered),Not Ready,
Other Errors}={15,1.00e-008,100,10,10,10}
++PDEV=[HDD000-01,HDD000-02],Num. of PDEVs=2

Example 2: Changing the threshold of the SSD when drive type is other than SLxxx-MxxxSS

MPC,,[Information],ORM Value,Alter,Normal end,Seq.=xxxxxxxxxx
+Type=Total
+{Total Defect Count}={15}
++PDEV=[HDD000-01,HDD000-02],Num. of PDEVs=2

Example 3: Changing the threshold of the SSD when drive type is SLxxx-MxxxSS

MPC,,[Information],ORM Value,Alter,Normal end,Seq.=xxxxxxxxxx
+Type=Total
+{Total Defect Count,Used Endurance Indicator}={160000,(99,90)}
++PDEV=[HDD000-03],Num. of PDEVs=1

Example 4: Changing the threshold of the FMD when drive type is NFHxx-Qxxxxx

MPC,,[Information],ORM Value,Alter,Normal end,Seq.=xxxxxxxxxx
+Type=Today
+{Total Defect Count,Reboot Error,DMA Error,Memory Error,
Uncorrected Error,Used Endurance Indicator,Capacitor Error}=
{0,2,10,500,512,(0,0),1}
++PDEV=[HDD000-03],Num. of PDEVs=1

Example 5: Error Reset

MPC,,[Information],ORM Value,Error Reset,Normal end,
Seq.=xxxxxxxxxx
+PDEV=HDD000-01