Example
Out-of-band,,[Config Command],,,Accept,Seq.=xxxxxxxxxx
+Command=Pairresync(RemoteCopy)
++Copy Kind=Remote
++P-VOL(Port-LUN-LDEV)=1A-2047-0x1A,S-VOL(Port-LUN-LDEV)=1B-3-0x3B,
MCU S/N=412345,RCU S/N=412345,
Virtual Storage Machine S/N=423456,
Write Permission(Update Copy Error)=Enable,
Write Permission(RCU Suspend Failure)=Enable,
Copy Pace(TRK)=1,JNL ID Option=Disable,CTG ID=100,Resync-SWAP=Disable,
CTG Mode(Multi)=Enable,CTG Option=Enable,CTO Option=Enable,
Inflow Control=Enable,Offloading Timer(s)=1,Device Option=Enable
,IO Preference Mode=
Detailed Information
Item |
Description |
---|---|
Command |
The command name |
Copy Kind |
The remote copy Remote is output as the fixed value. |
P-VOL(Port-LUN-LDEV)*1 |
The port number, the LU number, and the LDEV number of the primary volume The port number and the LU number show the expanded LU of Command Control Interface The LU number is the absolute LUN*2 of Command Control Interface |
S-VOL(Port-LUN-LDEV)*1 |
The port number, the LU number, and the LDEV number of the secondary volume The port number and the LU number show the expanded LU of Command Control Interface No value is output when the option "-swaps" or "-swapp" is specified. The LU number is the absolute LUN*2 of Command Control Interface |
MCU S/N*1 |
The serial number of the local storage system |
RCU S/N*1 |
The serial number of the remote storage system No value is output when the option "-swaps" or "-swapp" is specified. |
Virtual Storage Machine S/N |
The serial number of the virtual storage machine No value is output when a virtual storage machine is not specified. |
Write Permission(Update Copy Error) |
The setting status of write permission if an error occurs during update copy Enable: Enabled, Disable: Disabled Enable is output when the option "-swaps" or "-swapp" is specified. |
Write Permission(RCU Suspend Failure) |
The setting status of permission to write to the local storage system if the suspension operation cannot be performed on the remote storage system Enable: Enabled, Disable: Disabled Enable is output when the option "-swaps" or "-swapp" is specified. |
Copy Pace(TRK) |
The track size for copy |
JNL ID Option |
Indicates whether an option (-jp or -js) is specified for a journal ID Enable: Specified, Disable: Not specified Disable is output for pairs other than Universal Replicator ones. |
CTG ID |
The consistency group ID No value is output when the option "-swaps" or "-swapp" is specified. |
Resync-SWAP |
Indicates whether an option (-swaps or -swapp) is specified Enable: Specified, Disable: Not specified |
CTG Mode(Multi) |
Indicates whether pairs are specified for consistency groups across multiple storage systems Enable: Specified, Disable: Not specified Disable is output for pairs other than Universal Replicator ones. |
CTG Option |
Indicates whether the consistency group option (-fg) is specified Enable: Specified, Disable: Not specified If the option "-swaps" or "-swapp" is specified, Disable is output for Universal Replicator pair. |
CTO Option |
Indicates whether the CTO option (-cto) is specified Enable: Specified, Disable: Not specified |
Inflow Control |
The setting status of the inflow control mode Enable: Enabled, Disable: Disabled No value is output when the CTO option is not specified. |
Offloading Timer(s) |
The time out value for the inflow control in seconds No value is output when the CTO option is not specified or the inflow control mode is disabled. |
Device Option |
Indicates whether the volume name defined in the configuration definition file is used Enable: Used, Disable: Not used |
IO Preference Mode |
I/O preference mode for when a failure occurs on the remote path between the primary and secondary storage systems (I/O Preference Mode When Remote Path Failed). A value is displayed when I/O Preference Mode When Remote Path Failed is specified. P-VOL: Primary Volume (the mode in which the primary volume is given priority) Disable: I/O Preference Mode When Remote Path Failed is disabled. |
*1 When a virtual storage machine is specified, the value of the virtual storage machine is output. *2 For more information about the absolute LUN, see Command Control Interface Installation and Configuration Guide |