Paircreate(RemoteCopy)

Audit Log User Guide for VSP E Series and VSP G130, G/F350, G/F370, G/F700, G/F900

Version
88-07-0x
Audience
anonymous
Part Number
MK-97HM85024-10

Example

Out-of-band,,[Config Command],,,Accept,Seq.=xxxxxxxxxx
+Command=Paircreate(RemoteCopy)
++Copy Kind=Remote
++P-VOL(Port-LUN-LDEV)=1A-2047-0x1A,S-VOL(Port-LUN-LDEV)=1B-3-0x3B,
MCU S/N=412345,RCU S/N=422364,
Virtual Storage Machine S/N=423456,
Write Permission(Update Copy Error)=Enable,
Write Permission(RCU Suspend Failure)=Enable,
Initial Copy=None,Copy Pace(TRK)=1,JNL ID Option=Disable,CTG ID=100,
CTG Mode(Multi)=Disable,Paircreate Mode(Diff)=Normal,CTG Option=Enable,
CTO Option=Enable,Inflow Control=Disable,Offloading Timer(s)=,M-JNL=,
R-JNL=,Quorum Disk ID=,Device Option=Enable,IO Preference Mode=

Detailed Information

Item

Description

Command

The command name

Copy Kind

The remote copy

Remote is output as the fixed value.

P-VOL(Port-LUN-LDEV)*1

The port number, the LU number, and the LDEV number of the primary volume

The port number and the LU number show the expanded LU of Command Control Interface

The LU number is the absolute LUN*2 of Command Control Interface

S-VOL(Port-LUN-LDEV)*1

The port number, the LU number, and the LDEV number of the secondary volume

The port number and the LU number show the expanded LU of Command Control Interface

The LU number is the absolute LUN*2 of Command Control Interface

MCU S/N*1

The serial number of the local storage system

RCU S/N*1

The serial number of the remote storage system

Virtual Storage Machine S/N

The serial number of the virtual storage machine

No value is output when a virtual storage machine is not specified.

Write Permission(Update Copy Error)

The setting status of write permission if an error occurs during update copy

Enable: Enabled, Disable: Disabled

Write Permission(RCU Suspend Failure)

The setting status of permission to write to the local storage system if the suspension operation cannot be performed on the remote storage system

Enable: Enabled, Disable: Disabled

Initial Copy

The type of pair creation

Entire: Creates pairs and copies data from the primary volume to the secondary volume

None: Creates pairs and does not copy data from the primary volume to the secondary volume

Copy Pace(TRK)

The track size for copy

JNL ID Option

Indicates whether an option (-jp or -js) is specified for a journal ID

Enable: Specified, Disable: Not specified

Disable is output for pairs other than Universal Replicator ones

CTG ID

The consistency group ID

0 (zero) is output if the consistency group option (-fg) is not specified.

CTG Mode(Multi)

Indicates whether pairs are specified for consistency groups across multiple storage systems

Enable: Specified, Disable: Not specified

Disable is output for pairs other than Universal Replicator ones

Paircreate Mode(Diff)

The pair creation mode

Normal: Normal mode, Diff: Difference mode

Normal is output for pairs other than Universal Replicator ones.

CTG Option

Indicates whether the consistency group option (-fg) is specified

Enable: Specified, Disable: Not specified

CTO Option

Indicates whether the CTO option (-cto) is specified

Enable: Specified, Disable: Not specified

Inflow Control

The setting status of the inflow control mode

Enable: Enabled, Disable: Disabled

No value is output when the CTO option is not specified.

Offloading Timer(s)

The time out value for the inflow control in seconds

No value is output when the CTO option is not specified or the inflow control mode is disabled.

M-JNL

The master journal number

No value is output for pairs other than Universal Replicator ones.

R-JNL

The restore journal number

No value is output for pairs other than Universal Replicator ones.

Quorum Disk ID

The Quorum Disk ID

No value is output for pairs other than global-active device ones.

Device Option

Indicates whether the volume name defined in the configuration definition file is used

Enable: Used, Disable: Not used

IO Preference Mode

I/O preference mode for when a failure occurs on the remote path between the primary and secondary storage systems (I/O Preference Mode When Remote Path Failed). A value is displayed when I/O Preference Mode When Remote Path Failed is specified.

P-VOL: Primary Volume (the mode in which the primary volume is given priority)

*1 When a virtual storage machine is specified, the value of the virtual storage machine is output.

*2 For more information about the absolute LUN, see Command Control Interface Installation and Configuration Guide