Modify Snapshot(Resync)

Audit Log User Guide for VSP E Series and VSP G130, G/F350, G/F370, G/F700, G/F900

Version
88-07-0x
Audience
anonymous
Part Number
MK-97HM85024-10

Example

Out-of-band,,[Config Command],,,Accept,Seq.=xxxxxxxxxx
+Command=Modify Snapshot(Resync)
++P-VOL(LDKC:CU:LDEV)=0x00:0xAA:0xBB,MU=A,
Virtual Storage Machine S/N=423456

Detailed Information

Item

Description

Command

The command name

P-VOL(LDKC:CU:LDEV)

The LDEV ID of the primary volume shared by a pair to be resynchronized

When a virtual storage machine is specified, the LDEV ID of the virtual storage machine is output.

MU

The MU number of the pair to be resynchronized

Virtual Storage Machine S/N

The serial number of the virtual storage machine

No output when a virtual storage machine is not specified