Add RCU iSCSI Port

Audit Log User Guide for VSP E Series and VSP G130, G/F350, G/F370, G/F700, G/F900

Version
88-07-0x
Audience
anonymous
Part Number
MK-97HM85024-10

Example

Out-of-band,,[Config Command],,,Accept,Seq.=xxxxxxxxxx
+Command=Add RCU iSCSI Port
++S/N=400001,Controller ID=18,MCU Port=3B,RCU Port=4B,TCP Port=3260,
IP Address=192.168.0.169

Detailed Information

Item

Description

Command

The command name

S/N

The serial number of the remote storage system

Controller ID

The controller ID of the remote storage system

5: USP V/VM, 6: VSP, 7: VSP G1000/G1500 and VSP F1500, 8: VSP 5000 series, 18: VSP E series, VSP G130, G/F350, G/F370, G/F700, G/F900, VSP G200, G400, G600, G800, and VSP F400, F600, F800, 19: HUS VM

MCU Port

The port name of the local storage system

RCU Port

The port name of the remote storage system

TCP Port

The TCP port number

A hyphen (-) is displayed if the TCP port number is not specified.

IP Address

The IP address of the port on the remote storage system