Example
Out-of-band,,[Config Command],,,Accept,Seq.=xxxxxxxxxx +Command=Add RCU iSCSI Port ++S/N=400001,Controller ID=18,MCU Port=3B,RCU Port=4B,TCP Port=3260, IP Address=192.168.0.169
Detailed Information
Item |
Description |
---|---|
Command |
The command name |
S/N |
The serial number of the remote storage system |
Controller ID |
The controller ID of the remote storage system 5: USP V/VM, 6: VSP, 7: VSP G1000/G1500 and VSP F1500, 8: VSP 5000 series, 18: VSP E series, VSP G130, G/F350, G/F370, G/F700, G/F900, VSP G200, G400, G600, G800, and VSP F400, F600, F800, 19: HUS VM |
MCU Port |
The port name of the local storage system |
RCU Port |
The port name of the remote storage system |
TCP Port |
The TCP port number A hyphen (-) is displayed if the TCP port number is not specified. |
IP Address |
The IP address of the port on the remote storage system |