Add LUN

Audit Log User Guide for VSP E Series and VSP G130, G/F350, G/F370, G/F700, G/F900

Version
88-07-0x
Audience
anonymous
Part Number
MK-97HM85024-10

Example

Out-of-band,,[Config Command],,,Accept,Seq.=xxxxxxxxxx
+Command=Add LUN
++Port=1A,Host Group ID=0x1AA,LUN=2,
LDEV(LDKC:CU:LDEV)=0x00:0xAA:0xBB,
Virtual Storage Machine S/N=423456,Command Device=Enable
++Additional Port(Port,Host Group ID,LUN)
=[{1B,0x1AA,2},{1C,0x1AA,2}],Num. of Paths=2

Detailed Information

Item

Description

Command

The command name

Port

The name of a port to which an LU is added

When a virtual storage machine is specified, the port name of the virtual storage machine is output.

Host Group ID

The ID of a host group to which an LU is added

LUN

The LU number to be added

"Auto" is output when auto is specified instead of the LU number.

LDEV(LDKC:CU:LDEV)

The LDEV ID of an LDEV to be set as an LU.

Virtual Storage Machine S/N

The serial number of the virtual storage machine

No output when a virtual storage machine is not specified

Command Device

The setting status of the command device attribute

Enable: Enabled, Disable: Disabled

A hyphen (-) is output for the value when LUN is "Auto".

Additional Port(Port,Host Group ID,LUN)

The port name, the host group ID, and the LU number for the LU path to be added

If it is not specified by the command option, the item itself is not output.

"Auto" is output for the LUN of this item when LUN is "Auto".

Num. of Paths

The number of LU paths to be added

If it is not specified by the command option, the item itself is not output.