Add DP Pool

Audit Log User Guide for VSP E Series and VSP G130, G/F350, G/F370, G/F700, G/F900

Version
88-07-0x
Audience
anonymous
Part Number
MK-97HM85024-10

Example

Out-of-band,,[Config Command],,,Accept,Seq.=xxxxxxxxxx
+Command=Add DP Pool
++Pool ID=AA,Pool Name=AAAAAA,Warning Threshold(%)=85,
High water mark Threshold(%)=85
++LDEV(LDKC:CU:LDEV)={0x00:0xAA:0xBB,0x00:0xCC:0xDD,……,0x00:0xEE:0xFF},
Num. of LDEVs=X
++Suspend TI Pair=Yes

Detailed Information

Item

Description

Command

The command name

Pool ID

The pool number of a pool for Dynamic Provisioning to be created

Pool Name

The pool name of a pool for Dynamic Provisioning to be created

Warning Threshold(%)

The warning threshold of the usage rate of a pool for Dynamic Provisioning to be created

High water mark Threshold(%)

The depletion threshold of a pool for Dynamic Provisioning to be created

LDEV(LDKC:CU:LDEV)

The LDEV IDs for LDEVs of a pool volume

Num. of LDEVs

The number of pool volumes

Suspend TI Pair

The setting status of Suspend TI Pair when the High water mark Threshold is exceeded.

Yes: Thin Image pair is suspended.

No: Thin Image pair is not suspended.

A hyphen (-) is output if it is not specified at the command option