Add CHAP User

Audit Log User Guide for VSP E Series and VSP G130, G/F350, G/F370, G/F700, G/F900

Version
88-07-0x
Audience
anonymous
Part Number
MK-97HM85024-10

Example 1: Adding the CHAP user name on the target side

Out-of-band,,[Config Command],,,Accept,Seq.=xxxxxxxxxx
+Command=Add CHAP User
++Port=1A,Target ID=0xBB,Target CHAP User=XXXXXX,
Virtual Storage Machine S/N=423456

Detailed Information 1

Item

Description

Command

The command name

Port

The name of a port to which an iSCSI target, to which a CHAP user is added, belongs

Target ID

The iSCSI target ID

Target CHAP User

The CHAP user name on the target side

Virtual Storage Machine S/N

The serial number of the virtual storage machine

No value is output when a virtual storage machine is not specified.

Example 2: Adding the CHAP user name on the initiator side

Out-of-band,,[Config Command],,,Accept,Seq.=xxxxxxxxxx
+Command=Add CHAP User
++Port=1A,Target ID=0xBB,Initiator CHAP User=XXXXXX,
Virtual Storage Machine S/N=423456

Detailed Information 2

Item

Description

Command

The command name

Port

The name of a port to which an iSCSI target, to which a CHAP user is added, belongs

Target ID

The iSCSI target ID

Initiator CHAP User

The CHAP user name on the initiator side

Virtual Storage Machine S/N

The serial number of the virtual storage machine

No value is output when a virtual storage machine is not specified.