The controller chassis consists of a controller board, front-end module, back-end module, fabric-acceleration module, power supply, and cache flash memory. Controllers are storage system components that cache and manage data, and provide hosts with a coherent, virtualized view of the system. A controller chassis contains two nodes with a 4U controller each, making the chassis 8U high. A storage system can contain 2 to 6 nodes, depending on the storage system model.
The compression accelerator module, which includes the compression accelerator and a fan, is a hardware component for the VSP 5200 and VSP 5600. The compression accelerator performs compression for these models instead of the storage system controllers, resulting in improved performance for the controllers.
Number | Item | Description |
---|---|---|
1 | POWER LED |
Green: Storage system is powered on. Amber: Storage system is receiving power. |
2 | READY LED |
Green: Normal operation. |
3 | WARNING LED |
Off: Normal operation. Amber: Component requires maintenance. Blink: Failure requires maintenance. Note: When System Option Mode 1097 is set to ON, the WARNING LED does not blink, even if the following failure service information messages (SIM) are issued: 452xxx, 462xxx, 3077xx, 4100xx, and 410100. LED might turn off during user maintenance. |
4 | ALARM LED |
Off: Normal operation. Red: Processor failure (system might be down). For assistance, contact customer support: https://support.hitachivantara.com/en_us/contact-us.html. |
5 | POWER ON/OFF (main switch) |
Powers the storage system. |
Number | Item | Description |
---|---|---|
1 | Controllers |
Controller 1 (bottom) and Controller 2 (top). |
2 | Backup module | N/A |
3 | BACKUP LED |
Green: Power restoration in progress following power outage. Fast blink green: Restoring. Slow blink green: Restoring, or sequential shutdown in progress. |
4 | Cache flash memory | N/A |
5 | ALM LED (for cache flash memory) |
Red: Cache flash memory can be removed. |
6 |
CTL ALM LED |
Red: Controller can be removed. Blink red: Failure with the power supply unit of the controller. Amber: LAN reset switch was pressed. |
7 |
LAN-RST switch |
Use only when instructed by customer support. |
8 |
STATUS LED (for BKMF) |
Green: Charging of the battery in the backup module is complete. Red: Backup module can be removed. Blink red one time: Main battery failure. Blink red two times: Backup battery failure. Blink red three times: Both batteries failed or preventive maintenance replacement of batteries can run. Off: Battery is not mounted, battery-mounting failure occurred, or firmware is being upgraded. Off is normal status for configurations without batteries. |
9 |
POWER ON/OFF (main switch) |
Powers the storage system. |
10 |
POWER, READY, WARNING, and ALARM LEDs |
Note: When System Option Mode 1097 is set to ON, the WARNING LED does not blink, even if the following failure service information messages (SIM) are issued: 452xxx, 462xxx, 3077xx, 4100xx, and 410100. |
Number | Item |
---|---|
1 | Power supply unit |
2 | Front-end module |
3 | LAN blade |
4 | Fabric-acceleration module |
5 | Back-end module |
Number | Item | Description |
---|---|---|
1 | ALM / RDY LED | Red: Power supply unit can be replaced. |
2 | RDY LED | Green: Normal operation. |