The following table lists incorrect display errors and provides the probable cause and recommended action for each error condition.
Error condition | Probable cause / Recommended action |
---|---|
A question mark or icon is displayed in a table or other area of the window. |
|
The product name, vendor name, and function name displayed in HDvM - SN are incorrect. |
The product information might not be correctly obtained because of any of the following situations:
Check the execution status of the upgrade or downgrade of the controller model. If any of the previous situations does not apply, in the HDvM - SN main window, click File > Refresh All, and then confirm that the product name, vendor name, and function name in HDvM - SN are correct. If these items are still displayed incorrectly, ask maintenance personnel to restart the SVP. If the problem persists, contact customer support. |
A part of the HDvM - SN window is not displayed. | You might be using the zoom-in and zoom-out function of the web browser. Do not use this web browser function when using HDvM - SN. |
The display on HDvM - SN's main window is not updated to the latest information. "Last Updated" on HDvM - SN's main window is not updated. | Volume Migration, Quick Restore, Thin Image, or Thin Image Advanced operations might be in progress. The window will be updated shortly after the operations end. |
When many items are set, some items might not be displayed even if you scroll through the table. | Depending on the size of a window, some items in a table might not be displayed. Do the following:
Note: Text might become too small. If you still cannot solve the problem, contact customer support. |
The Tools panel of Google Chrome is not displayed correctly in Japanese. | Click the
|
.
The message "Unable to launch the application" appears on the secondary window, then operation ends abnormally. | Perform the following: If you use JRE 8, Solaris is not supported. Confirm Use TLS 1.2 for Java is enabled. If this problem persists after performing the above actions, click Detail in the window and collect information displayed in the window by copying and pasting it or by capturing the screen shot, and then contact customer support. |
After an upgrade or downgrade of the controller model, the display of HDvM - SN windows and buttons does not match the installed version. | The product information might not be correctly displayed because of any of the following situations:
Check the execution status of the upgrade or downgrade of the controller model. If any of the previous situations does not apply, in the HDvM - SN main window, click File > Refresh All, and then check the HDvM - SN windows and buttons. If they still do not match the installed version, ask maintenance personnel to restart the SVP. If the problem persists, contact customer support. |
A pop-up block message appears when Microsoft Edge is used. | In Microsoft Edge settings, pop-ups might be blocked. Change the settings in Microsoft Edge on the SVP to allow pop-ups. |