The following table lists and describes the failure trap reference codes.
For details on alert levels, see the System Administrator Guide.
Trap reference code |
Description |
Section |
Alert level |
Host report1 |
||
---|---|---|---|---|---|---|
SIM 22 |
SIM 23 |
SIM 13 |
||||
14 |
02 |
00 |
Communication error between MP and SVP |
SVP failure |
MODERATE |
Yes |
14 |
20 |
xx |
Transmitted data abnormality between MP and GUM |
Processor |
MODERATE |
Yes |
18 |
00 |
00 |
AuditLog lost |
DKC environment |
MODERATE |
Yes |
21 |
20 |
xx |
Channel port blocking |
Processor |
MODERATE |
Yes |
21 |
30 |
xx |
CHB blocking |
Environmental error |
MODERATE |
Yes |
21 |
60 |
xx |
HIE blocking |
Cache |
MODERATE |
Yes |
21 |
61 |
xx |
ISW blocking |
Cache |
MODERATE |
Yes |
21 |
62 |
xx |
X path blocking |
Cache |
MODERATE |
Yes |
21 |
63 |
xx |
HIE warning |
Cache |
MODERATE |
Yes |
21 |
64 |
xx |
X path warning |
Cache |
MODERATE |
Yes |
21 |
80 |
xx |
Logical path(s) on the remote copy connections was logically blocked (Due to an error condition) |
Processor |
MODERATE |
Yes2 |
21 |
81 |
xx |
RIO PATH AUTOMATICALLY RECOVERED |
Processor |
SERVICE |
No |
21 |
90 |
xx |
AL_PA VALUE CONFLICT |
Processor |
SERVICE |
No |
21 |
93 |
xx |
LINK FAILURE |
Processor |
SERIOUS |
Yes |
21 |
94 |
xx |
LINK FAILURE2 |
Processor |
SERIOUS |
Yes |
21 |
a3 |
xx |
HTP/Channel port blocking |
Processor |
MODERATE |
Yes |
21 |
a8 |
xx |
SFP wrong type |
Processor |
MODERATE |
No |
21 |
aa |
xx |
SFP TxFault |
Processor |
MODERATE |
No |
21 |
ab |
xx |
SFP warning |
Processor |
MODERATE |
Yes |
21 |
ac |
xx |
SFP alarm |
Processor |
MODERATE |
Yes |
21 |
bx |
xx |
HTP hard error |
Processor |
MODERATE |
Yes |
21 |
d0 |
xx |
External storage system connection path blocking |
Processor |
MODERATE |
Yes |
21 |
d1 |
xx |
External storage system connection path restore |
Processor |
SERVICE |
No |
21 |
d2 |
xx |
External storage system response delay |
Processor |
SERVICE |
Yes |
21 |
d4 |
xx |
Blocking the Data Migration path |
Processor |
MODERATE |
No |
21 |
d5 |
xx |
Data Migration Path Recovery |
Processor |
SERVICE |
No |
30 |
70 |
xx |
CHK1A THRESHOLD OVER |
Processor |
SERVICE |
No |
30 |
71 |
xx |
CHK1B THRESHOLD OVER |
Processor |
SERVICE |
No |
30 |
72 |
xx |
CHK3 THRESHOLD OVER |
Processor |
SERVICE |
No |
30 |
73 |
xx |
PROCESSOR BLOCKING |
Processor |
MODERATE |
Yes |
30 |
75 |
xx |
FM ERROR |
Processor |
MODERATE |
Yes |
30 |
76 |
xx |
Incorrect SUM value of FM |
Processor |
SERVICE |
No |
30 |
77 |
xx |
PROCESSOR MEMORY TEMPORARY ERROR |
Processor |
SERVICE |
No |
30 |
78 |
xx |
BFM error |
Processor |
SERIOUS |
Yes |
30 |
80 |
xx |
WCHK1 dump |
Processor |
MODERATE |
No |
30 |
a1 |
00 |
DKC Blockade |
Processor |
ACUTE |
Yes |
38 |
8f |
00 |
P/S OFF IMPOSSIBLE |
PS(DKC) |
MODERATE |
No |
38 |
9f |
00 |
P/S OFF IMPOSSIBLE(DEVICE RESERVED) |
PS(DKC) |
MODERATE |
No |
39 |
90 |
xx |
Undefined Package is mounted |
Processor |
MODERATE |
No |
39 |
91 |
xx |
V-R OR SERIAL NUMBER IS INCONSISTENT |
Processor |
MODERATE |
No |
39 |
93 |
xx |
REPLACE FAILED |
Processor |
MODERATE |
No |
39 |
9d |
xx |
Injustice DC voltage control |
Processor |
MODERATE |
Yes |
39 |
9e |
xx |
Injustice CEMODE |
Processor |
MODERATE |
Yes |
39 |
9f |
xx |
Injustice CEDT |
Processor |
MODERATE |
Yes |
39 |
b0 |
xx |
SMA SLAVE ERROR |
Processor |
SERVICE |
No |
3a |
0x |
xx |
LDEV Blockade (Effect of microcode error) |
Processor |
MODERATE |
Yes |
3c |
95 |
00 |
CHB/DKB Type disagreement |
Processor |
MODERATE |
No |
3c |
96 |
00 |
No CHB mounted |
CHB/DKB error |
MODERATE |
No |
3c |
97 |
xx |
ISCF microcode exchange warning |
CHB/DKB error |
MODERATE |
Yes |
3c |
98 |
00 |
ACLF type mismatch detected |
ACLF error |
MODERATE |
No |
41 |
00 |
xx |
Format complete |
Drive |
SERVICE |
No |
41 |
01 |
00 |
Quick Format finish |
Drive |
SERVICE |
No |
41 |
02 |
00 |
Parity consistency check completed |
Environment |
SERVICE |
No |
41 |
02 |
01 |
Parity consistency check suspended |
Environment |
SERVICE |
No |
41 |
03 |
00 |
Parity consistency check abnormality detection |
Environment |
MODERATE |
No |
43 |
4x |
xx |
DRIVE MEDIA ERROR6 |
Drive |
SERVICE |
No |
43 |
5x |
xx |
Drive media error |
Drive |
SERVICE |
No |
43 |
ax |
xx |
Drive blockade (media)(with redundancy)
|
Drive |
SERIOUS |
Yes |
43 |
bx |
xx |
Drive blockade (media)(with redundancy)6 |
Drive |
SERIOUS |
Yes |
43 |
cx |
xx |
Drive blockade (media)(without redundancy)6 |
Drive |
SERIOUS |
Yes |
43 |
dx |
xx |
Drive blockade (media)(without redundancy) |
Drive |
SERIOUS |
Yes |
46 |
8x |
xx |
Collection Copy/Copyback disabled(drive replace) |
Drive |
MODERATE |
No |
46 |
9x |
xx |
Collection Copy/Copyback disabled(drive replace) |
Drive |
MODERATE |
No |
46 |
ax |
xx |
Drive Copy/Correction Copy delay |
Drive |
MODERATE |
Yes |
46 |
bx |
xx |
Drive Copy/Correction Copy delay |
Drive |
MODERATE |
Yes |
46 |
cx |
xx |
Drive Copy/Correction Copy copy skip |
Drive |
MODERATE |
Yes |
46 |
dx |
xx |
Drive Copy/Correction Copy copy skip |
Drive |
MODERATE |
Yes |
47 |
dx |
xx |
SIMF/SI Copy abnormal end |
Failure with paired volumes |
MODERATE |
Yes |
47 |
e5 |
00 |
All FlashCopy(R) Option abnormal end by SM volatile |
Failure with paired volumes |
MODERATE |
Yes |
47 |
e7 |
00 |
Forcible suspend by SM volatile (SIMF/SI) |
Failure with paired volumes |
MODERATE |
Yes |
47 |
ec |
00 |
Thin Image ABNORMAL END BY SM VOLATILE |
Failure with paired volumes |
MODERATE |
Yes |
47 |
fx |
xx |
Volume Migration Abnormal End |
Volume Migration |
MODERATE |
Yes3 |
49 |
10 |
00 |
CACHE WRITE PENDING RATIO IS OVER 65% |
Cache |
SERVICE |
No |
49 |
3x |
xx |
Cache Write Pending warning threshold exceeded |
Cache |
MODERATE |
No |
4a |
80 |
xx |
Expander Micro Exchange failed |
Processor |
MODERATE |
No |
4b |
2x |
xx |
Compatible FlashCopy(R) ABNORMAL END |
Failure with paired volumes |
MODERATE |
Yes |
4b |
3x |
xx |
Thin Image ABNORMAL END |
Failure with paired volumes |
MODERATE |
Yes |
4b |
4x |
xx |
FlashCopy(R) Hierarchical memory access error |
Failure with paired volumes |
MODERATE |
Yes |
4b |
6x |
xx |
Correction copy start |
Failure with paired volumes |
SERVICE |
Yes |
4b |
7x |
xx |
Correction copy start |
Failure with paired volumes |
SERVICE |
Yes |
4b |
8x |
xx |
Correction copy normal end |
Failure with paired volumes |
SERVICE |
Yes |
4b |
9x |
xx |
Correction copy normal end |
Failure with paired volumes |
SERVICE |
Yes |
4b |
ax |
xx |
Correction copy abnormal end |
Failure with paired volumes |
SERIOUS |
Yes |
4b |
bx |
xx |
Correction copy abnormal end |
Failure with paired volumes |
SERIOUS |
Yes |
4b |
cx |
xx |
Correction copy discontinued |
Failure with paired volumes |
SERVICE |
No |
4b |
dx |
xx |
Correction copy discontinued |
Failure with paired volumes |
SERVICE |
No |
4b |
ex |
xx |
Correction copy warning end (With blockade LDEV or some error) |
Failure with paired volumes |
SERVICE |
Yes |
4b |
fx |
xx |
Correction copy warning end (With blockade LDEV or some error) |
Failure with paired volumes |
SERVICE |
Yes |
4c |
4x |
xx |
Flash module drive initialization failed |
Drive |
MODERATE |
Yes |
4c |
5x |
xx |
Flash module drive initialization failed |
Drive |
MODERATE |
Yes |
4c |
6x |
xx |
Dynamic sparing start (Drive copy) |
Drive |
SERVICE |
Yes |
4c |
7x |
xx |
Dynamic sparing start (Drive copy) |
Drive |
SERVICE |
Yes |
4c |
8x |
xx |
Dynamic sparing normal end (Drive copy) |
Drive |
SERVICE |
Yes |
4c |
9x |
xx |
Dynamic sparing normal end (Drive copy) |
Drive |
SERVICE |
Yes |
4c |
ax |
xx |
Dynamic sparing abnormal end (Drive copy) |
Drive |
MODERATE |
Yes |
4c |
bx |
xx |
Dynamic sparing abnormal end (Drive copy) |
Drive |
MODERATE |
Yes |
4c |
cx |
xx |
Dynamic sparing discontinued (Drive copy) |
Drive |
SERVICE |
No |
4c |
dx |
xx |
Dynamic sparing discontinued (Drive copy) |
Drive |
SERVICE |
No |
4c |
ex |
xx |
Dynamic sparing warning end (With blockade LDEV or some error) (Drive copy) |
Drive |
SERVICE |
Yes |
4c |
fx |
xx |
Dynamic sparing warning end (With blockade LDEV or some error) (Drive copy) |
Drive |
SERVICE |
Yes |
4d |
1x |
xx |
Differential area blocking |
Drive |
SERIOUS |
Yes |
4d |
6x |
xx |
PDEV Erase Start |
Drive |
SERVICE |
No |
4d |
7x |
xx |
PDEV Erase Start |
Drive |
SERVICE |
No |
4d |
8x |
xx |
PDEV Erase Normal End |
Drive |
SERVICE |
No |
4d |
9x |
xx |
PDEV Erase Normal End |
Drive |
SERVICE |
No |
4d |
ax |
xx |
PDEV Erase Abnormal End |
Drive |
SERVICE |
No |
4d |
bx |
xx |
PDEV Erase Abnormal End |
Drive |
SERVICE |
No |
4e |
0x |
xx |
Drive blockade due to Media Sanitization start |
Drive |
SERVICE |
Yes |
4e |
1x |
xx |
Drive blockade due to Media Sanitization start |
Drive |
SERVICE |
Yes |
4e |
2x |
xx |
Media Sanitization start |
Drive |
SERVICE |
Yes |
4e |
3x |
xx |
Media Sanitization start |
Drive |
SERVICE |
Yes |
4e |
4x |
xx |
Media Sanitization normal end |
Drive |
SERVICE |
Yes |
4e |
5x |
xx |
Media Sanitization normal end |
Drive |
SERVICE |
Yes |
4e |
6x |
xx |
Media Sanitization abnormal end |
Drive |
MODERATE |
Yes |
4e |
7x |
xx |
Media Sanitization abnormal end |
Drive |
MODERATE |
Yes |
4e |
8x |
xx |
Media Sanitization warning end |
Drive |
MODERATE |
Yes |
4e |
9x |
xx |
Media Sanitization warning end |
Drive |
MODERATE |
Yes |
50 |
0x |
xx |
Drive temporary error |
Drive |
SERVICE |
No |
50 |
1x |
xx |
DRIVE TEMPORARY ERROR |
Drive |
SERVICE |
No |
50 |
2x |
xx |
DRIVE MEDIA ERROR6 |
Drive |
SERVICE |
No |
50 |
3x |
xx |
Drive media error |
Drive |
SERVICE |
No |
50 |
ax |
xx |
Flash drive End of life |
Drive |
SERVICE |
Yes |
50 |
bx |
xx |
Flash drive End of life6 |
Drive |
SERVICE |
Yes |
50 |
cx |
xx |
Flash module drive End of life6 |
Drive |
SERVICE |
Yes |
50 |
dx |
xx |
Flash module drive battery warning6 |
Drive |
SERVICE |
No |
60 |
2x |
xx |
Pool blocking7 |
Thin Image pool |
MODERATE |
Yes |
60 |
30 |
00 |
SM Space Warning |
SM |
MODERATE |
Yes4 |
60 |
4x |
xx |
Exceeded Threshold of pool use rate |
Thin Image pool |
MODERATE |
Yes |
60 |
5x |
xx |
Actual pool use rate reaches upper limit |
Thin Image pool |
MODERATE |
Yes |
60 |
6x |
xx |
Exceeded Fixed outage Threshold of pool use rate |
Thin Image pool |
MODERATE |
Yes |
61 |
00 |
xx |
BACKUP/RESTORE SM INFORMATION FAILED |
SM |
MODERATE |
No |
62 |
3x |
xx |
The DP POOL error is detected (XXX : Pool ID) |
Dynamic Provisioning pool |
MODERATE |
Yes |
62 |
40 |
00 |
SM(DP/TI) AREA DEPLETION |
Dynamic Provisioning pool |
MODERATE |
Yes |
62 |
7x |
xx |
The DP POOL LDEV blockade |
Dynamic Provisioning pool |
SERIOUS |
Yes |
62 |
80 |
00 |
DP Protect attribute setting of DRU |
Dynamic Provisioning pool |
SERIOUS |
Yes |
62 |
9x |
xx |
Exceeded Warning Threshold of DP pool use rate |
Dynamic Provisioning pool |
MODERATE |
Yes |
62 |
ax |
xx |
DP pool use rate reaches upper limit |
Dynamic Provisioning pool |
MODERATE |
Yes |
62 |
b0 |
00 |
Threshold of DP pool use rate remains exceeded |
Dynamic Provisioning pool |
MODERATE |
Yes |
62 |
cx |
xx |
Exceeded Depletion Threshold of DP pool use rate |
Dynamic Provisioning pool |
MODERATE |
Yes |
62 |
dx |
xx |
Exceeded Fixed outage Threshold of DPpool use rate |
Dynamic Provisioning pool |
MODERATE |
Yes |
62 |
ex |
xx |
Exceeded DP pool depletion threshold for TI pairs |
Dynamic Provisioning pool |
MODERATE |
Yes |
63 |
1x |
xx |
Auto pool expansion failed due to system error |
Dynamic Provisioning pool |
MODERATE |
Yes |
63 |
2x |
xx |
Auto pool expansion failed due to pool error |
Dynamic Provisioning pool |
MODERATE |
Yes |
63 |
3x |
xx |
Failed to create, expand, or delete pools |
Pool error |
MODERATE |
Yes |
63 |
4x |
xx |
Auto pool expansion failed due to no more LDEV IDs |
Dynamic Provisioning pool |
MODERATE |
Yes |
64 |
1x |
xx |
Tier relocation is not completed |
Dynamic Tiering pool |
SERVICE |
Yes |
66 |
01 |
00 |
No free encryption key |
Encryption key |
MODERATE |
Yes |
66 |
02 |
00 |
Remaining free encryption key warning |
Encryption key |
SERVICE |
Yes |
66 |
10 |
xx |
Acquisition of encryption key from KMS failed |
Encryption key |
MODERATE |
Yes |
66 |
20 |
xx |
Encryption key setting abnormality |
Processor |
SERIOUS |
Yes |
67 |
00 |
00 |
Warning for depletion of cache management devices |
Thin Image |
MODERATE |
Yes |
68 | 00 | xx | Dedupe and compression abnormality detect |
dedupe and compression failure |
MODERATE | Yes |
68 |
1x |
xx |
dedupe system volume deletion abnormal end |
dedupe and compression failure |
MODERATE |
Yes |
68 |
20 |
00 |
dedupe system volume deletion suspended |
dedupe and compression failure |
MODERATE |
Yes |
68 |
3x |
xx |
Log structured area depletion alert |
dedupe and compression |
MODERATE |
Yes |
68 |
4x |
xx |
Log structured area depletion is solved |
dedupe and compression |
SERVICE |
Yes |
68 |
9x |
xx |
dedupe system volume change comp_acl abnormal end |
dedupe and compression failure |
MODERATE |
Yes |
68 |
bx |
xx |
dedupe and compression meta data access failure |
dedupe and compression failure |
MODERATE |
Yes |
70 |
xx |
00 |
Logical inconsistency |
SVP failure |
MODERATE |
No |
71 |
xx |
00 |
Heap error |
SVP failure |
MODERATE |
No |
72 |
xx |
00 |
File error |
SVP failure |
MODERATE |
No |
73 |
xx |
xx |
LAN error |
SVP failure |
MODERATE |
No |
74 |
xx |
xx |
SSVP error |
SVP failure |
MODERATE |
Yes |
75 |
xx |
00 |
Windows error |
SVP failure |
MODERATE |
No |
76 |
00 |
00 |
CUDG3 detected error |
SVP failure |
MODERATE |
No |
7b |
00 |
03 |
ISDN Router failure |
SVP failure |
MODERATE |
Yes |
7c |
00 |
00 |
SVP reboot stop (FD Inserted) |
SVP failure |
MODERATE |
No |
7c |
02 |
00 |
Audit Log failure of Host instruction configuration change |
SVP failure |
MODERATE |
No |
7c |
03 |
00 |
Audit Log FTP Transfer failed |
SVP failure |
MODERATE |
Yes |
7c |
04 |
00 |
Dump Tool failed |
SVP failure |
SERVICE |
Yes |
7c |
05 |
00 |
Invalid SIM data detection |
SVP failure |
SERVICE |
No |
7c | 08 | 00 | Dump collection starts | SVP failure | SERVICE | No |
7c | 09 | 00 | Dump collection ends normally | SVP failure | SERVICE | No |
7c | 0a | 00 | Dump collection ends abnormally | SVP failure | SERVICE | No |
7c | 0b | 00 | Cancellation of the dump collection completed | SVP failure | SERVICE | No |
7d |
00 |
xx |
GUM error |
GUM detection error |
MODERATE |
No |
7d |
01 |
xx |
LAN error(Internal Network) |
GUM detection error |
MODERATE |
Yes |
7d |
02 |
xx |
LAN error(CTL1-CTL2) |
GUM detection error |
MODERATE |
Yes |
7d |
06 |
xx |
MP error |
GUM detection error |
MODERATE |
Yes |
7d |
07 |
xx |
GUM security error detected |
GUM detection error |
MODERATE |
Yes |
7d |
08 |
xx |
Failed to recover GUM configuration information |
GUM detection error |
MODERATE |
Yes |
7d |
09 |
0x |
DKC warning |
GUM detection error |
SERIOUS |
Yes |
7d |
0a |
xx |
GUM version warning |
GUM detection error |
MODERATE |
Yes |
7e |
12 |
xx |
MP usage threshold exceeded |
Monitor |
MODERATE |
Yes |
7e |
20 |
xx |
Loss Of Signal Count(Fibre) Excess |
Monitor |
MODERATE |
No |
7e |
21 |
xx |
Bad Received Character Count(Fibre) Excess |
Monitor |
MODERATE |
No |
7e |
22 |
xx |
Loss Of Synchronization Count(Fibre) Excess |
Monitor |
MODERATE |
No |
7e |
23 |
xx |
Link Failure Count(Fibre) Excess |
Monitor |
MODERATE |
No |
7e |
24 |
xx |
Received EOFa Count(Fibre) Excess |
Monitor |
MODERATE |
No |
7e |
25 |
xx |
Discarded Frame Count(Fibre) Excess |
Monitor |
MODERATE |
No |
7e |
26 |
xx |
Bad CRC Count(Fibre) Excess |
Monitor |
MODERATE |
No |
7e |
27 |
xx |
Protocol Error Count(Fibre) Excess |
Monitor |
MODERATE |
No |
7e |
28 |
xx |
Expired Frame Count (Fibre) Excess |
Monitor |
MODERATE |
No |
7e |
29 |
xx |
HTP/FNP Multiplicity Excess |
Monitor |
MODERATE |
No |
7e |
2a |
xx |
FEC Un-correctable Count(Fibre) threshold exceeded |
Monitor |
MODERATE |
No |
7e |
2c |
xx |
HTP/FNP read data transfer threshold exceeded |
Monitor |
MODERATE |
No |
7e |
2d |
xx |
HTP/FNP write data transfer threshold exceeded |
Monitor |
MODERATE |
No |
7e |
2e |
xx |
HTP/FNP usage threshold exceeded |
Monitor |
MODERATE |
No |
7e |
30 |
00 |
Read Hit Ratio Excess |
Monitor |
MODERATE |
No |
7e |
50 |
xx |
MAC CRC Error Count(iSCSI) threshold exceeded |
Monitor |
MODERATE |
No |
7e |
51 |
xx |
IP Error Packet Count(iSCSI) threshold exceeded |
Monitor |
MODERATE |
No |
7e |
52 |
xx |
IPv6 Error Packet Count(iSCSI) threshold exceeded |
Monitor |
MODERATE |
No |
7e |
53 |
xx |
TCP Retransmit Timer Expired Count(iSCSI) exceeded |
Monitor |
MODERATE |
No |
7e |
54 |
xx |
iSCSI Header Digest Error Count(iSCSI) exceeded |
Monitor |
MODERATE |
No |
7e |
55 |
xx |
iSCSI Data Digest Error Count(iSCSI) exceeded |
Monitor |
MODERATE |
No |
7e |
ax |
xx |
Cache Use threshold exceeded |
Monitor |
MODERATE |
No |
7e |
bx |
xx |
Cache Write Pending threshold exceeded |
Monitor |
MODERATE |
No |
7e |
cx |
xx |
Cache MCU Side File Use threshold exceeded |
Monitor |
MODERATE |
No |
7f |
f1 |
00 |
TCMF/TC |
SVP failure |
SERVICE |
No |
7f |
f1 |
02 |
SIMF/SI |
SVP failure |
SERVICE |
No |
7f |
f1 |
03 |
URMF/UR |
SVP failure |
SERVICE |
No |
7f |
f1 |
04 |
TI |
SVP failure |
SERVICE |
No |
7f |
f1 |
05 |
FlashCopy(R) |
SVP failure |
SERVICE |
No |
7f |
f1 |
06 |
Volume Migration |
SVP failure |
SERVICE |
No |
7f |
f2 |
xx |
STANDBY SVP FAIL |
SVP failure |
MODERATE |
No |
7f |
f3 |
xx |
SVP FAIL OVER |
SVP failure |
MODERATE |
No |
7f |
f7 |
xx |
The term of validity is over |
License key |
MODERATE |
Yes |
7f |
f8 |
xx |
The capacity of validity is over |
License key |
MODERATE |
Yes |
7f |
f9 |
xx |
The PP is invalid by assumption PP invalidity |
License key |
MODERATE |
Yes |
7f |
fa |
0x |
Synchronization time failure |
SVP failure |
SERVICE |
Yes |
ac |
50 |
xx |
DB power off |
PS(DKU) |
MODERATE |
Yes |
ac |
51 |
xx |
DB power recovered |
PS(DKU) |
SERVICE |
Yes |
ac |
60 |
00 |
DKC was set to power error mode |
PS(DKC) |
MODERATE |
No |
ac |
61 |
00 |
DKC was released from power error mode |
PS(DKC) |
SERVICE |
No |
ac |
62 |
00 |
When DKC was set to power error mode, Urgent Destaging start succeeded |
PS(DKC) |
SERVICE |
No |
ac |
63 |
00 |
When DKC was set to power error mode, Urgent Destaging start failed. |
PS(DKC) |
MODERATE |
No |
ac |
91 |
00 |
Open host reservation |
DKC environment |
MODERATE |
Yes |
af |
00 |
xx |
Injustice JP Warning |
Environmental error |
MODERATE |
Yes |
af |
10 |
xx |
MP Temperature abnormality warning |
Environmental error |
MODERATE |
Yes |
af |
11 |
xx |
External temperature warning |
Environmental error |
MODERATE |
Yes |
af |
12 |
xx |
External temperature alarm |
Environmental error |
MODERATE |
Yes |
af |
13 |
xx |
Thermal monitor warning |
Environmental error |
MODERATE |
Yes |
af |
20 |
xx |
DKCPS warning |
Environmental error |
MODERATE |
Yes |
af |
21 |
xx |
DKCPS input voltage abnormality |
Environmental error |
MODERATE |
Yes |
af |
30 |
xx |
Environmental microcontroller warning |
Environmental error |
MODERATE |
Yes |
af |
31 |
xx |
Device movement mode warning |
Environmental error |
MODERATE |
Yes |
af |
32 |
xx |
Environmental Firmware Update warning |
Environmental error |
MODERATE |
Yes |
af |
33 |
xx |
Voltage change setting warning |
Environmental error |
MODERATE |
Yes |
af |
40 |
xx |
BKM/BKMF warning |
Environmental error |
MODERATE |
Yes |
af |
41 |
xx |
Battery replacement should be scheduled |
Environmental error |
MODERATE |
Yes |
af |
4d |
xx |
Panel switch warning |
Environmental error |
MODERATE |
Yes |
af |
4e |
xx |
Invalid PS ON warning |
Environmental error |
MODERATE |
Yes |
af |
51 |
xx |
DBPS-1 warning |
PS(DKU) |
MODERATE |
Yes |
af |
52 |
xx |
DBPS-2 warning |
PS(DKU) |
MODERATE |
Yes |
af |
61 |
xx |
DBPS-1 input voltage abnormality |
PS(DKU) |
MODERATE |
Yes |
af |
62 |
xx |
DBPS-2 input voltage abnormality |
PS(DKU) |
MODERATE |
Yes |
af |
70 |
00 |
DB External temperature warning |
Environmental error |
MODERATE |
Yes |
af |
71 |
00 |
DB External temperature Alarm |
Environmental error |
MODERATE |
Yes |
af |
81 |
xx |
ENC-1 warning |
Environmental error |
MODERATE |
Yes |
af |
82 |
xx |
ENC-2 warning |
Environmental error |
MODERATE |
Yes |
af |
b0 |
xx |
HSNBX ambient temperature warning |
Environmental error |
MODERATE |
Yes |
af |
b1 |
xx |
ISW PS warning |
Environmental error |
MODERATE |
Yes |
af |
b2 |
xx |
ISW FAN warning |
Environmental error |
MODERATE |
Yes |
af |
b3 |
xx |
ISW PS input voltage abnormality |
Environmental error |
MODERATE |
Yes |
af |
b4 |
xx |
ISW warning |
Environmental error |
MODERATE |
Yes |
af |
b5 |
xx |
HSNBX thermal monitor warning |
Environmental error |
MODERATE |
Yes |
af |
b6 |
xx |
HSNBX PANEL JP setting abnormality |
Environmental error |
MODERATE |
Yes |
af |
b7 |
xx |
HSNBX PANEL JP setting warning |
Environmental error |
MODERATE |
Yes |
af |
b8 |
xx |
HSNBX PSONOFF I/F inconsistent |
Environmental error |
MODERATE |
Yes |
af |
f0 |
xx |
SSW data disagreement |
DKC environment |
MODERATE |
No |
af |
f1 |
xx |
GUM warning |
Environmental error |
MODERATE |
Yes |
af |
f2 |
xx |
CFM error |
Processor |
MODERATE |
Yes |
af |
f3 |
xx |
FAN warning |
Environmental error |
MODERATE |
Yes |
bf |
85 |
a3 |
JP remains |
Environment |
MODERATE |
Yes |
bf |
86 |
a3 |
JP remains |
Environment |
MODERATE |
Yes |
bf |
bx |
xx |
HSNPANEL error |
Environmental error |
MODERATE |
No |
bf |
e3 |
a2 |
Duplex SVP Setup fail |
SVP failure |
MODERATE |
Yes |
bf |
e4 |
00 |
SVP FAN0 error |
SVP failure |
MODERATE |
No |
bf |
e4 |
04 |
SVP disk error (SMART) |
Environmental error |
MODERATE |
No |
bf |
e4 |
07 |
USB interface error |
Environmental error |
MODERATE |
No |
cf |
10 |
xx |
SAS CTL blocking |
Processor |
MODERATE |
Yes |
cf |
11 |
xx |
SAS Port (WideLink) is partially blocked |
Processor |
SERVICE |
No |
cf |
12 |
xx |
SAS PORT blocked |
Processor |
MODERATE |
Yes |
cf |
13 |
xx |
Abnormal error detection |
Processor |
SERIOUS |
Yes |
cf |
20 |
xx |
PSW blockade |
Processor |
MODERATE |
Yes |
cf |
22 |
xx |
NVMe port blockade |
Processor |
MODERATE |
Yes |
cf |
88 |
xx |
CTL blocking |
Processor |
MODERATE |
Yes |
d0 |
0x |
xx |
TCMF/TC started the initial copy or out of sync for this volume |
Failure with paired volumes |
SERVICE |
Yes |
d0 |
1x |
xx |
TCMF/TC completed the initial copy for this volume |
Failure with paired volumes |
SERVICE |
Yes |
d0 |
2x |
xx |
TCMF/TC for this volume was deleted(Operation from an SVP/Web Console or a host processor) |
Failure with paired volumes |
SERVICE |
Yes |
d0 |
6x |
xx |
TCMF completed the Create pair (No copy suspend) |
Pair volume status error |
SERVICE |
Yes |
d1 |
0x |
xx |
Remote Copy pair status change (MCU Command) (From Simplex to Duplex Pending) |
Failure with paired volumes |
SERVICE |
Yes |
d1 |
1x |
xx |
Remote Copy pair status change (MCU Command) (From Simplex to Duplex) |
Failure with paired volumes |
SERVICE |
Yes |
d1 |
2x |
xx |
Remote Copy pair status change (MCU Command) (From Duplex Pending to Duplex) |
Failure with paired volumes |
SERVICE |
Yes |
d1 |
3x |
xx |
Remote Copy pair status change (MCU Command) (From Duplex Pending to Suspend) |
Failure with paired volumes |
SERVICE |
Yes |
d1 |
4x |
xx |
Remote Copy pair status change (MCU Command) (From Duplex to Suspend) |
Failure with paired volumes |
SERVICE |
Yes |
d1 |
5x |
xx |
Remote Copy pair status change (MCU Command) (From Duplex to Simplex) |
Failure with paired volumes |
SERVICE |
Yes |
d1 |
6x |
xx |
Remote Copy pair status change (MCU Command) (From Duplex Pending to Simplex) |
Failure with paired volumes |
SERVICE |
Yes |
d1 |
7x |
xx |
Remote Copy pair status change (MCU Command) (From Suspend to Simplex) |
Failure with paired volumes |
SERVICE |
Yes |
d1 |
8x |
xx |
Remote Copy pair status change (MCU Command) (From Suspend to Duplex Pending) |
Failure with paired volumes |
SERVICE |
Yes |
d1 |
9x |
xx |
Remote Copy pair status change (MCU Command) (From Duplex Pending to Suspend(continue)) |
Failure with paired volumes |
SERVICE |
Yes |
d1 |
ax |
xx |
Remote Copy pair status change (MCU Command) (From Duplex Pending to Suspend(complete)) |
Failure with paired volumes |
SERVICE |
Yes |
d1 |
bx |
xx |
Remote Copy pair status change (MCU Command) (From Suspend (continue) to Suspend) |
Failure with paired volumes |
SERVICE |
Yes |
d4 |
0x |
xx |
TCMF/TC for this volume was suspended (Due to an unrecoverable failure on the remote copy connections) |
Failure with paired volumes |
SERIOUS |
Yes |
d4 |
1x |
xx |
TCMF/TC for this volume was suspended (Due to an unrecoverable failure on the P-VOL or the remote copy connections) |
Failure with paired volumes |
SERIOUS |
Yes |
d4 |
2x |
xx |
TCMF/TC for this volume was suspended (Due to an unrecoverable failure on the S-VOL) |
Failure with paired volumes |
SERIOUS |
Yes |
d4 |
3x |
xx |
TCMF for this volume was suspended (Caused by DFW to the S-VOL was prohibited) |
Pair volume status error |
SERIOUS |
Yes |
d4 |
4x |
xx |
TCMF/TC for this volume was suspended (Due to an internal error condition detected by the RCU) |
Failure with paired volumes |
SERIOUS |
Yes |
d4 |
5x |
xx |
TCMF/TC for this volume was suspended (Caused by Delete pair operation was issued to the S-VOL) |
Failure with paired volumes |
SERIOUS |
Yes |
d4 |
6x |
xx |
The S-VOL has suspended. (Due to an unrecoverable failure on the remote copy connections) |
Failure with paired volumes |
SERIOUS |
Yes |
d4 |
7x |
xx |
The S-VOL has suspended (Due to an unrecoverable failure on the S-VOL) |
Failure with paired volumes |
SERIOUS |
Yes |
d4 |
fx |
xx |
Status of the P-VOL was not consistent with the S-VOL |
Failure with paired volumes |
SERIOUS |
Yes |
d5 |
7x |
xx |
Command device operation execution of command device in state of ONLINE |
Drive |
SERVICE |
No |
d8 |
0x |
xx |
A volume to be used by the URMF/UR was defined |
Failure with paired volumes |
SERVICE |
Yes5 |
d8 |
1x |
xx |
The volume being used by the URMF/UR began a copying |
Failure with paired volumes |
SERVICE |
Yes5 |
d8 |
2x |
xx |
The volume being used by the URMF/UR completed a copying |
Failure with paired volumes |
SERVICE |
Yes5 |
d8 |
3x |
xx |
The volume being used by the URMF/UR received a request for suspension |
Failure with paired volumes |
SERVICE |
Yes5 |
d8 |
4x |
xx |
The volume being used by the URMF/UR completed a suspension transaction |
Failure with paired volumes |
SERVICE |
Yes5 |
d8 |
5x |
xx |
The volume being used by the URMF/UR received a request for deletion |
Failure with paired volumes |
SERVICE |
Yes5 |
d8 |
6x |
xx |
The volume being used by the URMF/UR completed the deletion |
Failure with paired volumes |
SERVICE |
Yes5 |
d8 |
7x |
xx |
The volume being used by the URMF/UR was defined (placed in the PSUS status immediately) |
Failure with paired volumes |
SERVICE |
Yes5 |
d8 |
8x |
xx |
A Delta volume to be used by the URMF/UR was defined |
Failure with paired volumes |
SERVICE |
Yes5 |
d8 |
9x |
xx |
A Delta volume to be used by the URMF/UR was redefined |
Failure with paired volumes |
SERVICE |
Yes5 |
d9 |
0x |
xx |
A change to an S-VOL was received from the MCU (From Simplex to Duplex Pending) |
Failure with paired volumes |
SERVICE |
Yes5 |
d9 |
1x |
xx |
A change to an S-VOL was received from the MCU (From Simplex to Duplex) |
Failure with paired volumes |
SERVICE |
Yes5 |
d9 |
2x |
xx |
A change to an S-VOL was received from the MCU (From Duplex Pending to Duplex) |
Failure with paired volumes |
SERVICE |
Yes5 |
d9 |
3x |
xx |
A change to an S-VOL was received from the MCU (From Duplex Pending to Suspend) |
Failure with paired volumes |
SERVICE |
Yes5 |
d9 |
4x |
xx |
A change to an S-VOL was received from the MCU (From Duplex to Suspend) |
Failure with paired volumes |
SERVICE |
Yes5 |
d9 |
5x |
xx |
A change to an S-VOL was received from the MCU (From Duplex to Simplex) |
Failure with paired volumes |
SERVICE |
Yes5 |
d9 |
6x |
xx |
A change to an S-VOL was received from the MCU (From Duplex Pending to Simplex) |
Failure with paired volumes |
SERVICE |
Yes5 |
d9 |
7x |
xx |
A change to an S-VOL was received from the MCU (From Suspend to Simplex) |
Failure with paired volumes |
SERVICE |
Yes5 |
d9 |
8x |
xx |
A change to an S-VOL was received from the MCU (From Suspend to Duplex Pending) |
Failure with paired volumes |
SERVICE |
Yes5 |
d9 |
9x |
xx |
A change to an S-VOL was received from the MCU (HOLD -> PAIR) |
Failure with paired volumes |
SERVICE |
Yes5 |
d9 |
ax |
xx |
A change to an S-VOL was received from the MCU (HOLD -> COPY) |
Failure with paired volumes |
SERVICE |
Yes5 |
d9 |
bx |
xx |
A change to an S-VOL was received from the MCU (HOLD -> SMPL) |
Failure with paired volumes |
SERVICE |
Yes5 |
d9 |
cx |
xx |
A change to an S-VOL was received from the MCU (From Simplex to Suspend) |
Failure with paired volumes |
SERVICE |
Yes5 |
d9 |
dx |
xx |
A change to an S-VOL was received from the MCU (SMPL -> HOLD) |
Failure with paired volumes |
SERVICE |
Yes5 |
d9 |
ex |
xx |
A change to an S-VOL was received from the MCU (PSUx(Suspend) -> HOLD) |
Failure with paired volumes |
SERVICE |
Yes5 |
d9 |
fx |
xx |
A change to an S-VOL was received from the MCU (From Duplex to Duplex Pending) |
Failure with paired volumes |
SERVICE |
Yes5 |
da |
0x |
xx |
A change to an S-VOL was received from the RCU (A request for suspension was received.) |
Failure with paired volumes |
SERVICE |
No |
da |
1x |
xx |
A change to an S-VOL was received from the RCU (A suspension transaction was completed.) |
Failure with paired volumes |
SERVICE |
No |
da |
2x |
xx |
A change to an S-VOL was received from the RCU (An instruction to delete a pair was received in the Suspend status.) |
Failure with paired volumes |
SERVICE |
No |
da |
3x |
xx |
A change to an S-VOL was received from the RCU (An instruction to delete a pair was received in the Duplex Pending status.) |
Failure with paired volumes |
SERVICE |
No |
da |
4x |
xx |
A change to an S-VOL was received from the RCU (An instruction to delete a pair was received in the Duplex status.) |
Failure with paired volumes |
SERVICE |
No |
da |
5x |
xx |
A change to an S-VOL was received from the RCU (A pair deletion was completed.) |
Failure with paired volumes |
SERVICE |
No |
da |
6x |
xx |
A change to an S-VOL was received from the RCU (An instruction to delete a pair was received in the Hold status.) |
Failure with paired volumes |
SERVICE |
No |
db |
0x |
xx |
Drive port temporary error |
Drive error |
SERVICE |
No |
db |
1x |
xx |
Drive port temporary error |
Drive error |
SERVICE |
No |
db |
2x |
xx |
Drive port temporary error |
Drive error |
SERVICE |
No |
db |
3x |
xx |
Drive port temporary error |
Drive error |
SERVICE |
No |
db |
4x |
xx |
Drive port blockade |
Drive error |
MODERATE |
Yes |
db |
5x |
xx |
Drive port blockade |
Drive error |
MODERATE |
Yes |
db |
6x |
xx |
Drive port blockade |
Drive error |
MODERATE |
Yes |
db |
7x |
xx |
Drive port blockade |
Drive error |
MODERATE |
Yes |
db |
8x |
xx |
LDEV blockade (Effect of Drive port blockade) |
Drive error |
SERIOUS |
Yes |
db |
9x |
xx |
LDEV blockade (Effect of Drive port blockade) |
Drive error |
SERIOUS |
Yes |
db |
ax |
xx |
LDEV blockade (Effect of Drive port blockade) |
Drive error |
SERIOUS |
Yes |
db |
bx |
xx |
LDEV blockade (Effect of Drive port blockade) |
Drive error |
SERIOUS |
Yes |
db |
cx |
xx |
Drive Link Rate Abnormality |
Drive error |
SERVICE |
Yes |
db |
dx |
xx |
Drive Link Rate Abnormality |
Drive error |
SERVICE |
Yes |
db |
ex |
xx |
Drive Link Rate Abnormality |
Drive error |
SERVICE |
Yes |
db |
fx |
xx |
Drive Link Rate Abnormality |
Drive error |
SERVICE |
Yes |
dc |
0x |
xx |
PAIR SUSPEND(RIO PATH CLOSE) |
Failure with paired volumes |
SERIOUS |
Yes5 |
dc |
1x |
xx |
PAIR SUSPEND(MVOL ERROR) |
Failure with paired volumes |
SERIOUS |
Yes5 |
dc |
2x |
xx |
PAIR SUSPEND(RVOL ERROR) |
Failure with paired volumes |
SERIOUS |
Yes5 |
dc |
4x |
xx |
PAIR SUSPEND(SUSPEND REPORT) |
Failure with paired volumes |
SERIOUS |
Yes5 |
dc |
5x |
xx |
PAIR SUSPEND(SIMPLEX REPORT) |
Failure with paired volumes |
SERIOUS |
Yes5 |
dc |
6x |
xx |
PAIR SUSPEND(COMMUNICATION ERROR AT RCU) |
Failure with paired volumes |
SERIOUS |
Yes5 |
dc |
7x |
xx |
PAIR SUSPEND(ERROR DETECTED AT RCU) |
Failure with paired volumes |
SERIOUS |
Yes5 |
dc |
8x |
xx |
A volume being used by an S-VOL was suspended (PS OFF on the MCU side was detected) |
Failure with paired volumes |
SERVICE |
No |
dc |
9x |
xx |
ERASE FAIL |
Failure with paired volumes |
SERIOUS |
Yes5 |
dc |
ax |
xx |
Pair suspend (Spread by error of another Affiliate) |
Failure with paired volumes |
SERIOUS |
Yes5 |
dc |
e0 |
xx |
URMF/UR M-JNL Meta overflow warning |
Failure with paired volumes |
MODERATE |
No |
dc |
e1 |
xx |
URMF/UR M-JNL Data overflow warning |
Failure with paired volumes |
MODERATE |
No |
dc |
e2 |
xx |
URMF/UR R-JNL Meta overflow warning |
Failure with paired volumes |
MODERATE |
No |
dc |
e3 |
xx |
URMF/UR R-JNL Data overflow warning |
Failure with paired volumes |
MODERATE |
No |
dc |
f0 |
xx |
The URMF/UR Read JNL was interrupted for one minute (A failure on the MCU side was detected) |
Failure with paired volumes |
MODERATE |
No |
dc |
f1 |
xx |
The URMF/UR Read JNL was interrupted for five minutes (A failure on the MCU side was detected) |
Failure with paired volumes |
SERIOUS |
No |
dc |
f2 |
xx |
The URMF/UR Read JNL was interrupted for one minute (A failure on the RCU side was detected) |
Failure with paired volumes |
MODERATE |
No |
dc |
f3 |
xx |
The URMF/UR Read JNL was interrupted for five minutes (A failure on the RCU side was detected) |
Failure with paired volumes |
SERIOUS |
No |
dc |
f4 |
xx |
URMFxURMF/URxUR M-JNL Meta full Warning |
Failure with paired volumes |
MODERATE |
No |
dc |
f5 |
xx |
URMFxURMF/URxUR M-JNL Data full Warning |
Failure with paired volumes |
MODERATE |
No |
dc |
f6 |
xx |
Unassigned remote command device warning in 3DC |
Failure with paired volumes |
MODERATE |
Yes |
dd |
0x |
xx |
GAD for this volume was suspended (Due to an unrecoverable failure on the remote copy connections) |
Failure with paired volumes |
SERIOUS |
Yes |
dd |
1x |
xx |
GAD for this volume was suspended (Due to a failure on the volume) |
Failure with paired volumes |
SERIOUS |
Yes |
dd |
2x |
xx |
GAD for this volume was suspended (Due to an internal error condition detected) |
Failure with paired volumes |
SERIOUS |
Yes |
dd |
3x |
xx |
Status of the P-VOL was not consistent with the S-VOL |
Failure with paired volumes |
SERIOUS |
Yes |
de |
e0 |
xx |
Quorum Disk Restore |
Drive |
SERVICE |
Yes |
de |
f0 |
xx |
Quorum Disk Blocked |
Drive |
SERIOUS |
Yes |
df |
ex |
xx |
Response late Drive |
Drive |
SERVICE |
No |
df |
fx |
xx |
Response late Drive6 |
Drive |
SERVICE |
No |
eb |
0x |
xx |
Drive blockade (drive)(with redundancy) |
Drive |
SERIOUS |
Yes |
eb |
1x |
xx |
Drive blockade (drive)(with redundancy) |
Drive |
SERIOUS |
Yes |
eb |
2x |
xx |
Drive blockade (drive)(without redundancy) |
Drive |
SERIOUS |
Yes |
eb |
3x |
xx |
Drive blockade (drive)(without redundancy) |
Drive |
SERIOUS |
Yes |
eb |
4x |
xx |
Drive blockade (Effect of Dynamic sparing normal end) |
Drive |
SERVICE |
Yes |
eb |
5x |
xx |
Drive blockade (Effect of Dynamic sparing normal end) |
Drive |
SERVICE |
Yes |
eb |
6x |
xx |
Correction access occurred |
Drive |
SERIOUS |
Yes |
eb |
7x |
xx |
Correction access occurred |
Drive |
SERIOUS |
Yes |
eb |
8x |
xx |
Reboot stopped due to much write pending data |
Drive |
SERVICE |
No |
eb |
9x |
xx |
Reboot stopped due to much write pending data |
Drive |
SERVICE |
No |
ee |
00 |
00 |
Volume I/O upper limit reached |
QoS alert |
SERVICE |
Yes |
ee |
10 |
00 |
Volume I/O lower limit not reached |
QoS alert |
SERVICE |
Yes |
ee |
20 |
00 |
Volume I/O response delay |
QoS alert |
SERVICE |
Yes |
ee |
30 |
00 |
QoS group I/O upper limit reached |
QoS alert |
SERVICE |
Yes |
ee |
50 |
00 |
QoS group I/O response delay |
QoS alert |
SERVICE |
Yes |
ef |
4x |
xx |
PINNED SLOT |
Drive |
MODERATE |
No |
ef |
5x |
xx |
Abnormal end of Write processing in External storage system |
Drive |
MODERATE |
No |
ef |
8x |
xx |
LDEV blockade (Effect of drive blockade) |
Drive |
SERIOUS |
Yes |
ef |
9x |
xx |
LDEV blockade (Effect of drive blockade)6 |
Drive |
SERIOUS |
Yes |
ef |
ax |
xx |
DRIVE TEMPORARY ERROR6 |
Drive |
SERVICE |
No |
ef |
bx |
xx |
Drive temporary error |
Drive |
SERVICE |
No |
ef |
d0 |
00 |
External storage system connection device blockade |
Drive |
SERIOUS |
Yes |
ef |
d4 |
00 |
Blocking the Data Migration source device |
Drive |
MODERATE |
No |
ef |
fd |
xx |
Expander failure |
Environmental error |
SERIOUS |
Yes |
ef |
fe |
xx |
UNIT CONNECTION ERROR |
DKC environment |
MODERATE |
Yes |
fe |
00 |
00 |
Cache battery is being charged |
Cache |
SERIOUS |
Yes |
fe |
01 |
0x |
End of Cache Write Through |
Cache |
SERVICE |
No |
fe |
02 |
0x |
Start of Cache Write Through |
Cache |
MODERATE |
Yes |
fe |
03 |
0x |
Cache SSD mounting capacity shortage |
Cache |
SERIOUS |
No |
fe |
04 |
xx |
No CHB mounted |
Cache |
SERIOUS |
Yes |
ff |
21 |
xx |
LANB blocking |
Processor |
MODERATE |
Yes |
ff |
4x |
xx |
PINNED SLOT |
Cache |
MODERATE |
No |
ff |
5x |
xx |
Abnormal end of Read processing in External storage system |
Drive |
MODERATE |
No |
ff |
c3 |
0x |
CACHE PACKAGE BLOCKADE PROCESSING END |
Cache |
SERVICE |
Yes |
ff |
cb |
xx |
CTL patrol check error |
Cache |
SERVICE |
No |
ff |
cc |
xx |
CFM patrol check error |
Cache |
MODERATE |
No |
ff |
cd |
0x |
Area is volatilized |
Cache |
SERVICE |
No |
ff |
cf |
xx |
Package is volatilized |
Cache |
SERVICE |
No |
ff |
d4 |
xx |
Constitution definition error |
Processor |
MODERATE |
No |
ff |
de |
xx |
WDCP loss of duplicated information |
SM |
SERVICE |
No |
ff |
e4 |
0x |
REPLACE FAILED |
Cache |
SERIOUS |
No |
ff |
e7 |
00 |
Rebooted with volatilization after an instantaneous down |
SM |
SERIOUS |
Yes |
ff |
e8 |
00 |
Definition/Installation mismatch |
SM |
SERIOUS |
No |
ff |
ea |
0x |
RECOVERY OF AREA BLOCKED TEMPORARILY WAS COMPLETED |
SM |
SERVICE |
Yes |
ff |
eb |
00 |
Configuration information restore by backup failed |
SM |
SERIOUS |
Yes |
ff |
ee |
0x |
AREA TEMPORARY BLOCKING |
SM |
SERVICE |
Yes |
ff |
ef |
00 |
Rebooted without volatilization after an instantaneous down |
SM |
SERVICE |
No |
ff |
f0 |
xx |
DIMM Correctable error |
Cache |
SERVICE |
No |
ff |
f3 |
0x |
PACKAGE BLOCKING |
Cache |
MODERATE |
Yes |
ff |
f4 |
00 |
AREA BLOCKING |
Cache |
SERIOUS |
Yes |
ff |
f4 |
01 |
AREA BLOCKING |
Cache |
SERIOUS |
Yes |
ff |
f5 |
0x |
Both areas failed |
Cache |
MODERATE |
No |
ff |
f7 |
xx |
GUM blocking |
Cache |
MODERATE |
Yes |
ff |
f9 |
0x |
REPLACE FAILED |
Cache |
SERVICE |
No |
ff |
fa |
xx |
Battery warning |
Battery |
MODERATE |
Yes |
ff |
fb |
xx |
Cache Uncorrectable error |
Cache |
MODERATE |
Yes |
ff |
fe |
xx |
Warning for forcible volatile mode |
Cache |
MODERATE |
Yes |
Legend:
|