[UVM] Reconnect ES VOLs

Audit Log User Guide for VSP 5000 Series

Version
90-09-0x
Audience
anonymous
Part Number
MK-98RD9010-13

If this operation is performed from Device Manager - Storage Navigator, this logged information indicates that the Reconnect External Volumes operation was only requested but not completed. However, if this operation is performed from the External API (if this logged information appears between the CflSet Start operation and the CflSet End operation), this logged information indicates that the Reconnect External Volumes operation was completed.

Example

09xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,RMI AP,uid=user-name,Task Name,
[UVM],Reconnect ES VOLs,,Normal end,
from=xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx,,Seq.=xxxxxxxxxx
+{Group,Result}=[{E1-1,Normal end},{E1-2,Normal end}, {E1-3,Normal end},{E1-4,Normal
end}],Num. of Groups=4

Detailed Information

Item

Description

Group

The group number of the external volume resumed

Result

The result of operation

Normal end: Normal end, Error(xxxx-yyyyy): Abnormal end

xxxx: Part code, yyyyy: Error code

Num. of Groups

The number of external volumes resumed