Example 1: when the copy type is TC
09xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,RMI AP,uid=user-name,, [Remote Replication],Split Pairs,,Normal end, from=xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx,,Seq.=xxxxxxxxxx +Copy Type=TC,{P-VOL(Port-G-ID-LUN),S-VOL(Port-G-ID-LUN), Type,S-VOL Write,Kind,VOL(LDKC:CU:LDEV),PairVOL(LDEV),Result} =[{1A-0x00-0,1B-0x00-0,P-VOL,Disable,S-VOL,-,-,Normal end}, {1A-0x00-1,1B-0x00-1,P-VOL,Disable,S-VOL,-,-,Normal end}, (Snip)-(Snip)],Num. of Pairs=xx
Detailed Information 1
Item |
Description |
---|---|
Copy Type |
The copy type of this operation TC: TrueCopy |
P-VOL(Port-G-ID-LUN) |
The port number, host group number, and LUN of the primary volume of a pair that uses a volume connected to a host by using Fibre Channel or iSCSI |
S-VOL(Port-G-ID-LUN) |
The port number, host group number, and LUN of the secondary volume of a pair that uses a volume connected to a host by using Fibre Channel or iSCSI |
Type |
The volume type of the volume on the primary site P-VOL: Primary volume, S-VOL: Secondary volume |
S-VOL Write |
Indicates whether the writing to the secondary volume is enabled Enable: Writing is enabled, Disable: Writing is disabled |
Kind |
Indicates whether the primary volume is writable after splitting a pair. P-VOL Failure: Not writable S-VOL: Writable |
VOL(LDKC:CU:LDEV) |
The LDKC number, CU number, and LDEV number of the volume (on the local storage system) of a pair that uses a volume connected to a host by using NVMe-oF |
PairVOL(LDEV) |
The LDEV number of the volume (on the remote storage system) of a pair that uses a volume connected to a host by using NVMe-oF |
Result |
The result of the operation Normal end: Normal end, Error(xxxx-yyyyy): Abnormal end where xxxx: Part code, yyyyy: Error code |
Num. of Pairs |
The number of split pairs |
Example 2: when the copy type is TCMF
09xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,RMI AP,uid=user-name,, [Remote Replication],Split Pairs,,Normal end, from=xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx,,Seq.=xxxxxxxxxx +Copy Type=TCMF,{VOL(LDKC:CU:LDEV),PairVOL(LDEV), Type,SSB,Kind,Result} =[{0x00:0x00:0x00,0xFE,P-VOL,Disable,S-VOL,Normal end}, {0x00:0x00:0x01,0xFF,P-VOL,Disable,S-VOL,Normal end}, (Snip)-(Snip)],Num. of Pairs=xx
Detailed Information 2
Item |
Description |
---|---|
Copy Type |
The copy type of this operation TCMF: TrueCopy for Mainframe |
VOL(LDKC:CU:LDEV) |
The LDKC, CU, and LDEV numbers of the volume on the primary site |
PairVOL(LDEV) |
The LDEV number of the paired volume |
Type |
The volume type of the connected volume P-VOL: Primary volume, S-VOL: Secondary volume |
SSB |
Whether to notify SSB (F/M = FB) to the host Enable: Notifies SSB, Disable: Does not notify SSB |
Kind |
Indicates whether the primary volume is writable after splitting a pair. P-VOL Failure: Not writable S-VOL: Writable |
Result |
The result of the operation Normal end: Normal end, Error(xxxx-yyyyy): Abnormal end where xxxx: Part code, yyyyy: Error code |
Num. of Pairs |
The number of split pairs |
Example 3: when the copy type is UR
09xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,RMI AP,uid=user-name,, [Remote Replication],Split Pairs,,Normal end, from=xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx,,Seq.=xxxxxxxxxx +Copy Type=UR +{P-VOL(Port-G-ID-LUN),S-VOL(Port-G-ID-LUN),MirrorID, S/N,CTRLID,Type,S-VOL Write,Range,Suspend Mode,P-VOL(LDKC:CU:LDEV), S-VOL(LDKC:CU:LDEV),Result} =[{4C-0x00-0,4A-0x00-0,0x00,67676,6,P-VOL,Disable,LU, Flush,-,-,Normal end}, {4C-0x00-1,4A-0x00-1,0x00,67676,6,P-VOL,Disable,LU, Flush,-,-,Normal end}],Num. of Requests=2
Detailed Information 3
Item |
Description |
---|---|
Copy Type |
The copy type of this operation UR: Universal Replicator |
P-VOL(Port-G-ID-LUN) |
The port number, host group number, and LUN of the primary volume of a pair that uses a volume connected to a host by using Fibre Channel or iSCSI |
S-VOL(Port-G-ID-LUN) |
The port number, host group number, and LUN of the secondary volume of a pair that uses a volume connected to a host by using Fibre Channel or iSCSI |
MirrorID |
The mirror ID |
S/N |
The serial number of the RCU |
CTRLID |
The controller ID of the RCU 6: VSP, 7: VSP G1000/G1500 and VSP F1500, 8: VSP 5000 series, 18: VSP G130, G/F350, G/F370, G/F700, G/F900, VSP G200, G400, G600, G800, and VSP F400, F600, F800 |
Type |
Indicates whether the split data volume is a primary or secondary data volume P-VOL: Primary, S-VOL: Secondary |
S-VOL Write |
Indicates whether the writing to the secondary volume is enabled Disable: Disabled, Enable: Enabled |
Range |
The split range Mirror: All the pairs are split that exist in the same mirror as the pair. LU: Only the pair is split. |
Suspend Mode |
Indicates how to handle updated data that is not reflected in the secondary volume. Flush: The updated data is reflected when splitting a pair. Purge: The updated data is not reflected when splitting a pair. However, the updated data is reflected when the pair is resynchronized later. |
P-VOL (LDKC:CU:LDEV) |
The LDKC number, CU number, and LDEV number of the primary volume of a pair that uses a volume connected to a host by using NVMe-oF |
S-VOL (LDKC:CU:LDEV) |
The LDKC number, CU number, and LDEV number of the secondary volume of a pair that uses a volume connected to a host by using NVMe-oF |
Result |
The result of the operation Normal end: Normal end, Error(xxxx-yyyyy): Abnormal end where xxxx: Part code, yyyyy: Error code |
Num. of Requests |
The number of split mirrors when Range is Mirror The number of split pairs when Range is LU |
Example 4: when the copy type is URMF
09xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,RMI AP,uid=user-name,, [Remote Replication],Split Pairs,,Normal end, from=xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx,,Seq.=xxxxxxxxxx +Copy Type=URMF ++{P-VOL(LDKC:CU:LDEV),S-VOL(LDKC:CU:LDEV),MirrorID,S/N, CTRLID,Type,S-VOL Write,Range,Suspend Mode,Result} =[{0x00:0x00:0x00,0x00:0x20:0x00,0x00,65432,6, P-VOL,Disable,Volume,Flush,Normal end}, {0x00:0x00:0x01,0x00:0x20:0x00,0x01,65432,6, P-VOL,Disable,Volume,Flush,Normal end}],Num. of Requests=2
Detailed Information 4
Item |
Description |
---|---|
Copy Type |
The copy type of this operation URMF: Universal Replicator for Mainframe |
P-VOL(LDKC:CU:LDEV) |
The LDKC, CU, and LDEV numbers of the primary data volume |
S-VOL(LDKC:CU:LDEV) |
The LDKC, CU, and LDEV numbers of the secondary data volume |
MirrorID |
The mirror ID |
S/N |
The serial number of the RCU |
CTRLID |
The controller ID of the RCU 6: VSP, 7: VSP G1000/G1500 and VSP F1500, 8: VSP 5000 series |
Type |
Indicates whether the split data volume is a primary or secondary data volume P-VOL: Primary, S-VOL: Secondary |
S-VOL Write |
Indicates whether the writing to the secondary volume is enabled Disable: Disabled, Enable: Enabled |
Range |
The split range Mirror: All the pairs are split that exist in the same mirror as the pair. Volume: Only the pair is split. |
Suspend Mode |
Indicates how to handle updated data that is not reflected in the secondary volume. Flush: The updated data is reflected when splitting a pair. Purge: The updated data is not reflected when splitting a pair. However, the updated data is reflected when the pair is resynchronized later. |
Result |
The result of the operation Normal end: Normal end, Error(xxxx-yyyyy): Abnormal end where xxxx: Part code, yyyyy: Error code |
Num. of Requests |
The number of split mirrors when Range is Mirror The number of split pairs when Range is Volume |