[Remote Replication] Create Pairs

Audit Log User Guide for VSP 5000 Series

Version
90-09-0x
Audience
anonymous
Part Number
MK-98RD9010-13

Example 1: when the copy type is TC

09xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,RMI AP,uid=user-name,,
[Remote Replication],Create Pairs,,Normal end,
from=xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx,,Seq.=xxxxxxxxxx
+Copy Type=TC,{P-VOL(Port-G-ID-LUN),S-VOL(Port-G-ID-LUN),
S/N,LDKC,ID,Controller ID,Type,Initial Copy,Fence Level,
Copy Pace,Priority,Diff,Result}
=[{1A-0x00-0,GR-0xFE-1023,99999,0x00,Default,6,Sync,Entire,
Never,15,032,Track,Normal end},(Snip)-(Snip)],Num. of Pairs=xx

Detailed Information 1

Item

Description

Copy Type

The copy type of this operation

TC: TrueCopy

P-VOL(Port-G-ID-LUN)

The port number, host group number, and LUN of the volume specified to the primary volume

S-VOL(Port-G-ID-LUN)

The port number, host group number, and LUN of the volume specified to the secondary volume

S/N

The serial number of the RCU

LDKC

The LDKC number of the RCU

ID

The path group ID or SSID

When the path group ID is default setting, "Default" is output.

Controller ID

The controller ID of the RCU

6: VSP, 7: VSP G1000/G1500 and VSP F1500, 8: VSP 5000 series, 18: VSP G130, G/F350, G/F370, G/F700, G/F900, VSP G200, G400, G600, G800, and VSP F400, F600, F800

Type

Type of the update copy operation

Outputs Sync (synchronization mode) as a fixed parameter.

Initial Copy

Type of the pair creation operation

Entire: Creates pairs and copies data from the primary volume to the secondary volume.

None: Creates pairs but does not copy data from the primary volume to the secondary volume.

Fence Level

Configured fence level (conditions where the local storage system rejects write operations to the primary volume)

Never: Can write to the primary volume even the pair is split.

Data: Cannot write to the primary volume when update copying fails.

Status: Cannot write to the primary volume, only when the storage system of the primary site cannot change the pair status of the secondary volume to PSUE.

Copy Pace

The setting of the initial copy speed (the number of tracks that can be copied at a time)

Priority

The priority of the set initial copy operation (scheduling order).

Diff

The unit of the difference management setting

Outputs Track as a fixed parameter.

Result

The result of the operation

Normal end: Normal end,

Error(xxxx-yyyyy): Abnormal end

where xxxx: Part code, yyyyy: Error code

Num. of Pairs

The number of create pairs

Example 2: when the copy type is TCMF

09xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,RMI AP,uid=user-name,,
[Remote Replication],Create Pairs,,Normal end,
from=xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx,,Seq.=xxxxxxxxxx
+Copy Type=TCMF,{P-VOL(LDKC:CU:LDEV),S-VOL(LDEV),
S/N,LDKC,SSID,Controller ID,Type,Initial Copy,Fence Level,
Copy Pace,Priority,Diff,CFW,DFW,TS,Result}
=[{0x00:0x00:0x00,0xFF,99999,0x00,0x0004,6,Sync,Entire,Never,
15,032,Track,Only P-VOL,Required,Enable,Normal end},
(Snip)-(Snip)],Num. of Pairs=xx

Detailed Information 2

Item

Description

Copy Type

The copy type of this operation

TCMF: TrueCopy for Mainframe

P-VOL(LDKC:CU:LDEV)

The LDKC, CU, and LDEV numbers of the primary volume

S-VOL(LDEV)

The LDEV number of the secondary volume

S/N

The serial number of the RCU

LDKC

The LDKC number of the RCU

SSID

The SSID of the RCU

Controller ID

The controller ID of the RCU

5: USP V/VM, 6: VSP, 7: VSP G1000/G1500 and VSP F1500, 8: VSP 5000 series

Type

Type of the update copy operation

Outputs Sync (synchronization mode) as a fixed parameter.

Initial Copy

Type of the pair creation operation

Entire: Creates pairs and copies data from the primary volume to the secondary volume.

None: Creates pairs but does not copy data from the primary volume to the secondary volume.

Fence Level

Configured fence level (conditions where the local storage system rejects write operations to the primary volume)

Never: Can write to the primary volume even the pair is split.

Data: Cannot write to the primary volume when update copying fails.

Status: Cannot write to the primary volume, only when the storage system of the primary site cannot change the pair status of the secondary volume to Suspend.

Copy Pace

The setting of the initial copy speed (the number of tracks that can be copied at a time)

Priority

The priority of the set initial copy operation (scheduling order).

Diff

The unit of the difference management setting

Outputs Track as a fixed parameter.

CFW

Whether to copy CFW (cache fast write) data to the secondary volume.

Only P-VOL: Does not copy, Copy to S-VOL: Copies

DFW

Whether the storage system of the primary site splits pairs when the storage system of the secondary site cannot copy DFW data to the secondary volume.

Required: Splits pairs.

Not Required: Does not split pairs.

TS

Indicates whether to transfer the host I/O time stamp to the secondary volume when creating a pair.

Enable: Transfer, Disable: Not transfer

Result

The result of the operation

Normal end: Normal end,

Error(xxxx-yyyyy): Abnormal end

where xxxx: Part code, yyyyy: Error code

Num. of Pairs

The number of create pairs

Example 3: when the copy type is UR

09xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,RMI AP,uid=user-name,,
[Remote Replication],Create Pairs,,Normal end,
from=xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx,,Seq.=xxxxxxxxxx
+Copy Type=UR
+{P-VOL(Port-G-ID-LUN),S-VOL(Port-G-ID-LUN),MirrorID,
S/N,CTRLID,Priority,CTG,Initial Copy,M-JNL,R-JNL,
Path Gr. ID,Error Level,Result}
=[{4C-0x00-0,4A-0x00-0,0x00,67676,6,32,0x000,Entire,
0x001,0x001,Default,Mirror,Normal end},
{4C-0x00-1,4A-0x00-1,0x00,67676,6,32,0x000,Entire,
0x001,0x001,Default,Mirror,Normal end}],Num. of Pairs=2

Detailed Information 3

Item

Description

Copy Type

The copy type of this operation

UR: Universal Replicator

P-VOL(Port-G-ID-LUN)

The port number, host group number, and LUN of the primary data volume

S-VOL(Port-G-ID-LUN)

The port number, host group number, and LUN of the secondary data volume

MirrorID

The mirror ID

S/N

The serial number of the RCU

CTRLID

The controller ID of the RCU

5: USP V/VM, 6: VSP, 7: VSP G1000/G1500 and VSP F1500, 8: VSP 5000 series, 18: VSP G130, G/F350, G/F370, G/F700, G/F900, VSP G200, G400, G600, G800, and VSP F400, F600, F800, 19: HUS VM

Priority

The priority of the set initial copy operation (scheduling order).

CTG

The consistency group ID

Initial Copy

Type of the pair creation operation

Entire: Creates pairs and copies data from the primary volume to the secondary volume.

None: Creates pairs but does not copy data from the primary volume to the secondary volume.

Delta: Creates delta resynchronization pairs.

M-JNL

The master journal number

R-JNL

The restore journal number

Path Gr. ID

The path group ID specified for the storage system

When the path group ID is default setting, "Default" is output.

Error Level

Range of the pair split at failure occurrence

Mirror: When a pair fails, all the pairs are split that exist in the same mirror as the pair.

LU: When a pair fails, only the pair is split.

Result

The result of the operation

Normal end: Normal end,

Error(xxxx-yyyyy): Abnormal end

where xxxx: Part code, yyyyy: Error code

Num. of Pairs

The number of created pairs

Example 4: when the copy type is URMF

09xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,RMI AP,uid=user-name,,
[Remote Replication],Create Pairs,,Normal end,
from=xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx,,Seq.=xxxxxxxxxx
+Copy Type=URMF
+{P-VOL(LDKC:CU:LDEV),S-VOL(LDKC:CU:LDEV),MirrorID,S/N,
CTRLID,Priority,Initial Copy,M-JNL,R-JNL,Path Gr. ID,
Error Level,CFW,Result}
=[{0x00:0x00:0x00,0x00:0x20:0x00,0x00,65432,6,32,Entire,
0x002,0x000,Default,Mirror,Copy to S-VOL,Normal end},
-{0x00:0x00:0x01,0x00:0x20:0x01,0x00,65432,6,32,Entire,
0x002,0x000,Default,Mirror,Copy to S-VOL,Normal end}],
Num. of Pairs=2

Detailed Information 4

Item

Description

Copy Type

The copy type of this operation

URMF: Universal Replicator for Mainframe

P-VOL(LDKC:CU:LDEV)

The LDKC, CU, and LDEV numbers of the primary data volume

S-VOL(LDKC:CU:LDEV)

The LDKC, CU, and LDEV numbers of the secondary data volume

MirrorID

The mirror ID

S/N

The serial number of the RCU

CTRLID

The controller ID of the RCU

5: USP V/VM, 6: VSP, 7: VSP G1000/G1500 and VSP F1500, 8: VSP 5000 series

Priority

The priority of the set initial copy operation (scheduling order).

Initial Copy

Type of the pair creation operation

Entire: Creates pairs and copies data from the primary volume to the secondary volume.

None: Creates pairs but does not copy data from the primary volume to the secondary volume.

Delta: Creates delta resynchronization pairs.

M-JNL

The master journal number

R-JNL

The restore journal number

Path Gr. ID

The path group ID specified for the storage system

When the path group ID is default setting, "Default" is output.

Error Level

Range of the pair split at failure occurrence

Mirror: When a pair fails, all the pairs are split that exist in the same mirror as the pair.

Volume: When a pair fails, only the pair is split.

CFW

Whether to copy CFW (cache fast write) data to the secondary volume.

Only P-VOL: Does not copy, Copy to S-VOL: Copies

Result

The result of the operation

Normal end: Normal end,

Error(xxxx-yyyyy): Abnormal end

where xxxx: Part code, yyyyy: Error code

Num. of Pairs

The number of created pairs

Example 5: when the copy type is GAD

09xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,RMI AP,uid=user-name,,
[Remote Replication],Create Pairs,,Normal end,
from=xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx,,Seq.=xxxxxxxxxx
+Copy Type=GAD,{P-VOL(Port-G-ID-LUN),S-VOL(Port-G-ID-LUN),
S/N_P,S/N_S,Path Gr.ID,Controller ID,SSID,Copy Pace,Quorum Disk ID,
MirrorID,CTG,Initial Copy,Result}=
[{1A-0x00-0,GR-0xFE-1023,62345,62355,0x00,7,0x0004,15,0x15, 0,
0x000, None,Normal end},(Snip)-(Snip)],Num. of Pairs=xx

Detailed Information 5

Item

Description

Copy Type

The copy type of this operation

GAD: global-active device

P-VOL(Port-G-ID-LUN)

The port number, host group number, and LUN of the primary volume

S-VOL(Port-G-ID-LUN)

The port number, host group number, and LUN of the secondary volume

S/N_P

The serial number of the local storage system

S/N_S

The serial number of the remote storage system

Path Gr.ID

Path group ID used in a global-active device pair

Controller ID

The controller ID of the remote storage system

5: USP V/VM, 6: VSP, 7: VSP G1000/G1500 and VSP F1500, 8: VSP 5000 series, 18: VSP G130, G/F350, G/F370, G/F700, G/F900, VSP G200, G400, G600, G800, and VSP F400, F600, F800, 19: HUS VM

SSID

The SSID

Copy Pace

The setting of the initial copy speed (the number of tracks that can be copied at a time)

Quorum Disk ID

The quorum disk ID used by global-active device

MirrorID

The mirror ID

CTG

The consistency group ID

A hyphen (-) is displayed if the consistency group is not specified.

Initial Copy

Type of the pair creation operation

Entire: Creates pairs and copies data from the primary volume to the secondary volume.

None: Creates pairs but does not copy data from the primary volume to the secondary volume.

Result

The result of the operation

Normal end: Normal end,

Error(xxxx-yyyyy): Abnormal end

where xxxx: Part code, yyyyy: Error code

Num. of Pairs

The number of created pairs