[Maintenance] Restore

Audit Log User Guide for VSP 5000 Series

Version
90-09-0x
Audience
anonymous
Part Number
MK-98RD9010-13

Example 1: restoring LDEV

09xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,SVP,uid=user-name,,[Maintenance],
Restore,,Normal end,from=xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx,,
Seq.=xxxxxxxxxx
+PG=[1-1],Num. of PGs=1

Detailed Information

Item

Description

PDEV

The location of the PDEV to be restored

PG

The parity group number

E1-1: In the case of an external volume

V1-1: In the case of a virtual volume

X1-1: In the case of a Dynamic Provisioning volume

Num. of PGs

The number of parity groups

LDEV

The LDKC number, the CU number, and the LDEV number

Num. of LDEVs

The number of LDEVs

Example 2: restoring a CTL (including CTL L), ENC, CFM, HIE, X-path cable, HSNBX, or ISW during replacement

09XX,0,YYYY/MM/DD,HH:MM:SS.xxx,00:00,GUM,,[Maintenance],Restore,,Normal
end,Seq.=xxxxxxxxxx
+Location=xxx

Detailed Information for Example 2

Item

Description

Location

The mounting location of the CTL, ENC, CFM, HIE, X-path cable, HSNBX, or ISW to be restored (CTLxx, ENCxxx-x, CFMxxx, HIE-xxx, ISWxx-x - HIE-xxx-x, HSNBX-x, or ISWxx).

When replacing a FAN or cache memory, the mounting location of the CTL to be restored is output. (This is because the CTL on which the FAN or cache memory to be replace is mounted is restored.)

Example 3: restoring a cache memory during replacement

09XX,0,YYYY/MM/DD,HH:MM:SS.xxx,00:00,GUM,,[Maintenance],Restore,,Normal
end,Seq.=xxxxxxxxxx
+Cache Size=xxxxxxxx,CFM Type for CFM010/020=xxx,CFM Type for
CFM011/021=xxx

Detailed Information for Example 3

Item

Description

Cache Size

The cache size of the cache memory to be restored

CFM Type for CFM010/020

The unit type of CFM010/020 that was installed

A hyphen (-) is displayed if the unit is not changed or mounted.

Displayed when a CFM of Node0 is installed.

CFM Type for CFM011/021

The unit type of CFM011/021 that was installed

A hyphen (-) is displayed if the unit is not changed or mounted.

CFM Type for CFM110/120

The unit type of CFM110/120 that was installed

A hyphen (-) is displayed if the unit is not changed or mounted.

Displayed when a CFM of Node1 is installed.

CFM Type for CFM111/121

The unit type of CFM111/121 that was installed

A hyphen (-) is displayed if the unit is not changed or mounted.

CFM Type for CFM210/220

The unit type of CFM210/220 that was installed

A hyphen (-) is displayed if the unit is not changed or mounted.

Displayed when a CFM of Node2 is installed.

CFM Type for CFM211/221

The unit type of CFM211/221 that was installed

A hyphen (-) is displayed if the unit is not changed or mounted.

CFM Type for CFM310/320

The unit type of CFM310/320 that was installed

A hyphen (-) is displayed if the unit is not changed or mounted.

Displayed when a CFM of Node3 is installed.

CFM Type for CFM311/321

The unit type of CFM311/321 that was installed

A hyphen (-) is displayed if the unit is not changed or mounted.

CFM Type for CFM410/420

The unit type of CFM410/420 that was installed

A hyphen (-) is displayed if the unit is not changed or mounted.

Displayed when a CFM of Node4 is installed.

CFM Type for CFM411/021

The unit type of CFM411/021 that was installed

A hyphen (-) is displayed if the unit is not changed or mounted.

CFM Type for CFM510/520

The unit type of CFM510/520 that was installed

A hyphen (-) is displayed if the unit is not changed or mounted.

Displayed when a CFM of Node5 is installed.

CFM Type for CFM511/521

The unit type of CFM511/521 that was installed

A hyphen (-) is displayed if the unit is not changed or mounted.

Example 4: restoring a CHB or DKB during replacement

09XX,0,YYYY/MM/DD,HH:MM:SS.xxx,00:00,GUM,,[Maintenance],Restore,,Normal
end,Seq.=xxxxxxxxxx
+Location=xxx,Type=xxxxxx

Detailed Information for Example 4

Item

Description

Location

The mounting location of the CHB or DKB to be restored (CHB-xxx or DKB-xxx)

Type

The unit type of the CHB or DKB to be restored

Example 5: restoring a ACLF during replacement

09XX,0,YYYY/MM/DD,HH:MM:SS.xxx,00:00,GUM,,[Maintenance],Restore,,Normal
end,Seq.=xxxxxxxxxx
+Location=xxx,Forcibly run without safety checks=Disable

Detailed Information for Example 5

Item

Description

Location

The mounting location of the ACLF to be restored (BKMF-xxx)

Forcibly run without safety checks

Indicates whether the function of forcible replacement (without running safety checks) is enabled.