Pairsplit(RemoteCopy)

Audit Log User Guide for VSP 5000 Series

Version
90-09-0x
Audience
anonymous
Part Number
MK-98RD9010-13
Note:

When splitting pairs in a consistency group, the audit log is registered only once for the direction of splitting the pair that uses the representative volume of the consistency group.

Example

09xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,Out-of-band,uid=user-name,,
[Config Command],,,Accept,from=xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx,,
Seq.=xxxxxxxxxx
+Command=Pairsplit(RemoteCopy)
++Copy Kind=Remote
++P-VOL(Port-LUN-LDEV)=1A-2047-0x1A,S-VOL(Port-LUN-LDEV)=1B-3-0x3B,
MCU S/N=12345,MCU SSID=0x6500,RCU S/N=22364,RCU SSID=0x3001,Range=LU,
Virtual Storage Machine S/N=23456,Suspend Status=P-VOL Failure,
S-VOL Write Permission (Suspend)=Disable,
P-VOL Write Permission (Force Suspend)=Disable,
Side File Liberation Kind=Flush,Rewind=Normal Suspend,CTG ID=100,
CTG Option=Disable,IO Mode=Local

Detailed Information

Item

Description

Command

The command name

Copy Kind

The remote copy

Remote is output as the fixed value.

P-VOL(Port-LUN-LDEV)*1

The port number, the LU number, and the LDEV number of the primary volume

The port number and the LU number show the expanded LU of Command Control Interface

No value is output when the option "-RS" is specified.

No value is output when the option "-iomd" is specified for the secondary volume.

The LU number is the absolute LUN*2 of Command Control Interface

S-VOL(Port-LUN-LDEV)*1

The port number, the LU number, and the LDEV number of the secondary volume

The port number and the LU number show the expanded LU of Command Control Interface

The LU number is the absolute LUN*2 ofCommand Control Interface

MCU S/N*1

The serial number of the local storage system

No value is output when the option "-RS" is specified.

No value is output when the option "-iomd" is specified for the secondary volume.

MCU SSID*1

The SSID to which a volume on the local storage system belongs

RCU S/N*1

The serial number of the remote storage system

RCU SSID*1

The SSID to which a volume on the remote storage system belongs

Range

The range of pair split

Group: Split by the device group unit

LU: Split by the LU unit

Virtual Storage Machine S/N

The serial number of the virtual storage machine

No value is output when a virtual storage machine is not specified.

Suspend Status

Indicates whether the primary volume is writable after splitting a TrueCopy pair.

P-VOL Failure: Not writable

S-VOL Suspend: Writable

S-VOL Suspend is output for pairs other than TrueCopy ones.

S-VOL Write Permission (Suspend)

Indicates whether the writing to the secondary volume is enabled in the suspend status

Enable: Enabled, Disable: Disabled

P-VOL Write Permission (Force Suspend)

Indicates whether the writing to the primary volume is enabled in the forcible suspend status

Enable: Enabled, Disable: Disabled

Side File Liberation Kind

The liberation kind of the side file

Flush: Flush is specified.

Purge: Purge is specified.

Rewind

Rewinds from SSWS to PSUS/PSUE

Normal Suspend: Normal suspend

SSWS Rewind: Rewound to PSUS/PSUE

CTG ID

The consistency group ID

No value is output when the consistency group option "-fg" is not specified.

CTG Option

Indicates whether the consistency group option (-fg) is specified

Enable: Specified, Disable: Not specified

IO Mode

Indicates which I/O mode the global-active device pair is changed to. A value is displayed only when the option "-iomd" is specified.

Local: The I/O mode is changed to Local.

Block: The I/O mode is changed to Block.

*1 When a virtual storage machine is specified, the value of the virtual storage machine is output.

*2 For more information about the absolute LUN, see Command Control Interface Installation and Configuration Guide