When splitting pairs in a consistency group, the audit log is registered only once for the direction of splitting the pair that uses the representative volume of the consistency group.
Example
09xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,Out-of-band,uid=user-name,,
[Config Command],,,Accept,from=xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx,,
Seq.=xxxxxxxxxx
+Command=Pairsplit(RemoteCopy)
++Copy Kind=Remote
++P-VOL(Port-LUN-LDEV)=1A-2047-0x1A,S-VOL(Port-LUN-LDEV)=1B-3-0x3B,
MCU S/N=12345,MCU SSID=0x6500,RCU S/N=22364,RCU SSID=0x3001,Range=LU,
Virtual Storage Machine S/N=23456,Suspend Status=P-VOL Failure,
S-VOL Write Permission (Suspend)=Disable,
P-VOL Write Permission (Force Suspend)=Disable,
Side File Liberation Kind=Flush,Rewind=Normal Suspend,CTG ID=100,
CTG Option=Disable,IO Mode=Local
Detailed Information
Item |
Description |
---|---|
Command |
The command name |
Copy Kind |
The remote copy Remote is output as the fixed value. |
P-VOL(Port-LUN-LDEV)*1 |
The port number, the LU number, and the LDEV number of the primary volume The port number and the LU number show the expanded LU of Command Control Interface No value is output when the option "-RS" is specified. No value is output when the option "-iomd" is specified for the secondary volume. The LU number is the absolute LUN*2 of Command Control Interface |
S-VOL(Port-LUN-LDEV)*1 |
The port number, the LU number, and the LDEV number of the secondary volume The port number and the LU number show the expanded LU of Command Control Interface The LU number is the absolute LUN*2 ofCommand Control Interface |
MCU S/N*1 |
The serial number of the local storage system No value is output when the option "-RS" is specified. No value is output when the option "-iomd" is specified for the secondary volume. |
MCU SSID*1 |
The SSID to which a volume on the local storage system belongs |
RCU S/N*1 |
The serial number of the remote storage system |
RCU SSID*1 |
The SSID to which a volume on the remote storage system belongs |
Range |
The range of pair split Group: Split by the device group unit LU: Split by the LU unit |
Virtual Storage Machine S/N |
The serial number of the virtual storage machine No value is output when a virtual storage machine is not specified. |
Suspend Status |
Indicates whether the primary volume is writable after splitting a TrueCopy pair. P-VOL Failure: Not writable S-VOL Suspend: Writable S-VOL Suspend is output for pairs other than TrueCopy ones. |
S-VOL Write Permission (Suspend) |
Indicates whether the writing to the secondary volume is enabled in the suspend status Enable: Enabled, Disable: Disabled |
P-VOL Write Permission (Force Suspend) |
Indicates whether the writing to the primary volume is enabled in the forcible suspend status Enable: Enabled, Disable: Disabled |
Side File Liberation Kind |
The liberation kind of the side file Flush: Flush is specified. Purge: Purge is specified. |
Rewind |
Rewinds from SSWS to PSUS/PSUE Normal Suspend: Normal suspend SSWS Rewind: Rewound to PSUS/PSUE |
CTG ID |
The consistency group ID No value is output when the consistency group option "-fg" is not specified. |
CTG Option |
Indicates whether the consistency group option (-fg) is specified Enable: Specified, Disable: Not specified |
IO Mode |
Indicates which I/O mode the global-active device pair is changed to. A value is displayed only when the option "-iomd" is specified. Local: The I/O mode is changed to Local. Block: The I/O mode is changed to Block. |