Paircreate(LocalCopy)

Audit Log User Guide for VSP 5000 Series

Version
90-09-0x
Audience
anonymous
Part Number
MK-98RD9010-13

Example

09xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,Out-of-band,uid=user-name,,
[Config Command],,,Accept,
from=xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx,,Seq.=xxxxxxxxxx
+Command=Paircreate(LocalCopy) ++Copy Kind=Local
++P-VOL(Port-LUN-LDEV)=1A-2047-0x1A, S-VOL(Port-LUN-LDEV)=1B-3-0x3B,MCU
S/N=12345,MCU SSID=0x6500, RCU S/N=12345,RCU SSID=0x6500, Virtual Storage
Machine S/N=23456, Copy Pace(TRK)=1,Range=Group,CTG ID=100,Split Mode=Normal,
S-VOL Hidden Mode=Enable,Pool ID(TI)=10, Device Option=Enable

Detailed Information

Item

Description

Command

The command name

Copy Kind

The local copy

Local is output as the fixed value.

P-VOL(Port-LUN-LDEV)*1

The port number, the LU number, and the LDEV number of the primary volume

The port number and the LU number show the expanded LU of Command Control Interface

The LU number is the absolute LUN*2 of Command Control Interface

S-VOL(Port-LUN-LDEV)*1

The port number, the LU number, and the LDEV number of the secondary volume

The port number and the LU number show the expanded LU of Command Control Interface

The LU number is the absolute LUN*2 of Command Control Interface

MCU S/N*1

The serial number of the local storage system

MCU SSID*1

The SSID to which the primary volume belongs

RCU S/N*1

The same value as that of MCU S/N is output.

RCU SSID*1

The SSID to which the secondary volume belongs

Virtual Storage Machine S/N

The serial number of the virtual storage machine

No value is output when a virtual storage machine is not specified.

Copy Pace(TRK)

The track size for copy

Range

Specifies a range of pairs to be created

Device: Specifies by the device

Group: Specifies by the consistency group

CTG ID

The consistency group ID

0 (zero) is output if the consistency group option (-m grp) is not specified.

Split Mode

The split mode when ShadowImage pairs are split

Normal: The pair is split normally.

Quick: The pair is split quickly.

If it is not specified at the command option or the pair is other than ShadowImage one, a hyphen (-) is output.

S-VOL Hidden Mode

Indicates whether the secondary volume is hidden after a ShadowImage pair is created

Enable: Hides the secondary volume

Disable: Not hides the secondary volume

Disable is output for pairs other than ShadowImage ones.

Pool ID(TI)

The pool ID of Thin Image (HTI only) pairs

0 (zero) is output for pairs other than Thin Image ones.

Device Option

Indicates whether the volume name defined in the configuration definition file is used

Enable: Used, Disable: Not used

*1 When a virtual storage machine is specified, the value of the virtual storage machine is output.

*2 For more information about the absolute LUN, see Command Control Interface Installation and Configuration Guide