Example
09xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,Out-of-band,uid=user-name,, [Config Command],,,Accept,from=xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx,, Seq.=xxxxxxxxxx +Command=Delete RCU ++S/N=512345,MCU=0xAAAA,RCU=0xBBBB,SSID=0x0123,Controller ID=8, Path Gr. ID=0
Detailed Information
Item |
Description |
---|---|
Command |
The command name |
S/N |
The serial number of the remote storage system |
MCU |
The CU number of the local storage system "Free" is output when CU Free is specified. |
RCU |
The CU number of the remote storage system "Free" is output when CU Free is specified. |
SSID |
The SSID of the remote storage system |
Controller ID |
The controller ID of the remote storage system 5: USP V/VM, 6: VSP, 7: VSP G1000/G1500 and VSP F1500, 8: VSP 5000 series, 18: VSP E series, VSP G130, G/F350, G/F370, G/F700, G/F900, VSP G200, G400, G600, G800, and VSP F400, F600, F800, 19: HUS VM |
Path Gr. ID |
The path group ID of the remote storage system No value is output when CU Free is not specified. |