Add CHAP User

Audit Log User Guide for VSP 5000 Series

Version
90-09-0x
Audience
anonymous
Part Number
MK-98RD9010-13

Example 1: Adding the CHAP user name on the initiator side

09xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,Out-of-band,uid=user-name,,
[Config Command],,,Accept,
from=xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx,,Seq.=xxxxxxxxxx +Command=Add CHAP User
++Port=1A,Target ID=0x00,Initiator CHAP User=AAAAAAA, Virtual Storage Machine
S/N=23456

Detailed Information 1: Adding the CHAP user name on the initiator side

Item

Description

Command

The command name

Port

The name of a port to which an iSCSI target, to which a CHAP user is added, belongs

Target ID

The iSCSI target ID

Initiator CHAP User

The CHAP user name on the initiator side

Virtual Storage Machine S/N

The serial number of the virtual storage machine

No value is output when a virtual storage machine is not specified.

Example 2: Adding the CHAP user name on the target side

09xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,Out-of-band,uid=user-name,,
[Config Command],,,Accept,
from=xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx,,Seq.=xxxxxxxxxx +Command=Add CHAP User
++Port=1A,Target ID=0x00,Target CHAP User=AAAAAAA, Virtual Storage Machine
S/N=23456

Detailed Information 2: Adding the CHAP user name on the target side

Item

Description

Command

The command name

Port

The name of a port to which an iSCSI target, to which a CHAP user is added, belongs

Target ID

The iSCSI target ID

Target CHAP User

The CHAP user name on the target side

Virtual Storage Machine S/N

The serial number of the virtual storage machine

No value is output when a virtual storage machine is not specified.