Example 1: Adding the CHAP user name on the initiator side
09xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,Out-of-band,uid=user-name,, [Config Command],,,Accept, from=xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx,,Seq.=xxxxxxxxxx +Command=Add CHAP User ++Port=1A,Target ID=0x00,Initiator CHAP User=AAAAAAA, Virtual Storage Machine S/N=23456
Detailed Information 1: Adding the CHAP user name on the initiator side
Item |
Description |
---|---|
Command |
The command name |
Port |
The name of a port to which an iSCSI target, to which a CHAP user is added, belongs |
Target ID |
The iSCSI target ID |
Initiator CHAP User |
The CHAP user name on the initiator side |
Virtual Storage Machine S/N |
The serial number of the virtual storage machine No value is output when a virtual storage machine is not specified. |
Example 2: Adding the CHAP user name on the target side
09xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,Out-of-band,uid=user-name,, [Config Command],,,Accept, from=xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx,,Seq.=xxxxxxxxxx +Command=Add CHAP User ++Port=1A,Target ID=0x00,Target CHAP User=AAAAAAA, Virtual Storage Machine S/N=23456
Detailed Information 2: Adding the CHAP user name on the target side
Item |
Description |
---|---|
Command |
The command name |
Port |
The name of a port to which an iSCSI target, to which a CHAP user is added, belongs |
Target ID |
The iSCSI target ID |
Target CHAP User |
The CHAP user name on the target side |
Virtual Storage Machine S/N |
The serial number of the virtual storage machine No value is output when a virtual storage machine is not specified. |