Example
09xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,In-band MF,uid=user-name,, [Config Command],,,Accept, from=xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx,,Seq.=xxxxxxxxxx +Command=EST PATH ++MCU S/N=02584,MCU SSID=0x1700,RCU S/N=32653,RCU SSID=0x1701, Controller ID=7 ++{MCU Port,RCU Port,RCU CU}=[{1A,5A,0x01}],Num. of Paths=1
Detailed Information
Item |
Description |
---|---|
Command |
The command name |
MCU S/N |
The serial number of the local storage system |
MCU SSID |
The SSID to which a volume on the local storage system belongs |
RCU S/N |
The serial number of the remote storage system |
RCU SSID |
The SSID to which a volume on the remote storage system belongs |
Controller ID |
The controller ID of the remote storage system 5: USP V/VM, 6: VSP, 7: VSP G1000/G1500 and VSP F1500 |
MCU Port |
The port name of the local storage system |
RCU Port |
The port name of the remote storage system |
RCU CU |
The CU number of the remote storage system |
Num. of Paths |
The number of paths to be created |