Resume Pair

Audit Log User Guide for VSP 5000 Series

Version
90-09-0x
Audience
anonymous
Part Number
MK-98RD9010-13

Example 1: when the copy type is SIMF

09xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,In-band MF,uid=user-name,,
[Config Command],,,Accept,
from=xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx,,Seq.=xxxxxxxxxx +Command=Resume Pair
++Copy Type=SIMF,I/F Version=0x04,Execute Type=Cmd. Device, S-VOL Check=Enable
++P-VOL(CU:LDEV)=0x00:0x00,S-VOL(CU:LDEV)=0x00:0x02, MCU S/N=32652,MCU
SSID=0x1B60,RCU S/N=32652,RCU SSID=0x1B60, Copy Pace=Slow,Resume Type=Steady,Resume
Mode=Reverse, Range=Group,CTG=0x7F

Example 2: when the copy type is TCMF

09xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,In-band MF,uid=user-name,,
[Config Command],,,Accept,
from=xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx,,Seq.=xxxxxxxxxx +Command=Resume Pair
++Copy Type=TCMF,I/F Version=0x31,Execute Type=Cmd. Device, S-VOL Check=Enable
++P-VOL(CU:LDEV)=0x00:0x00,S-VOL(CU:LDEV)=0x00:0x02, MCU S/N=32652,MCU
SSID=0x1B60,RCU S/N=32653,RCU SSID=0x1B60, Fence Level=,Copy Pace=Normal,Reverse
Resync Mode=Enable, Range=Group,Change CTG=Open/MF CTG,Time Stamp=Enable,
SCP=,CTG=0x7F

Example 3: when the copy type is URMF

09xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,In-band MF,uid=user-name,,
[Config Command],,,Accept,
from=xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx,,Seq.=xxxxxxxxxx +Command=Resume Pair
++Copy Type=URMF,I/F Version=0x40,Execute Type=Cmd. Device, S-VOL Check=Enable
++P-VOL(CU:LDEV)=0x00:0x00,S-VOL(CU:LDEV)=0x00:0x01, MCU S/N=32652,MCU
SSID=0x1B60,RCU S/N=32653,RCU SSID=0x1B60, Error Stop=,Reverse Resync
Mode=Disable,Range=Group, Error Level=,Mode=Delta

Detailed Information

Item

Description

Output items common to Example 1 to Example 3

Command

The command name

Copy Type

The copy type

SIMF: ShadowImage for Mainframe,

TCMF: TrueCopy for Mainframe,

URMF: Universal Replicator for Mainframe

I/F Version

The command interface version

Execute Type

The volume type for executing the command

Receive Device: LDEV which receives the command

Cmd. Device: Command device

S-VOL Check

The setting status of the option for confirming the use condition of the secondary volume

Enable: Enabled, Disable: Disabled

No value is output when Copy Type is URMF and Mode is Suspend.

P-VOL(CU:LDEV)

The CU number and the LDEV number of the primary volume

S-VOL(CU:LDEV)

The CU number and the LDEV number of the secondary volume

MCU S/N

The serial number of the local storage system

MCU SSID

The SSID to which a volume on the local storage system belongs

The SSID to which the primary volume belongs for operating ShadowImage for Mainframe pairs

RCU S/N

The serial number of the remote storage system

The same value as MCU S/N is output for operating ShadowImage for Mainframe pairs

RCU SSID

The SSID to which a volume on the remote storage system belongs

The SSID to which the secondary volume belongs for operating ShadowImage for Mainframe pairs

Output items when Copy Type is SIMF

Copy Pace

The copy speed

Slow: Slow, Normal: Normal, Fast: Fast

Resume Type

The pair resynchronization type

Steady: Normal resync, Quick: High-speed resync

Resume Mode

The pair resynchronization direction

Normal: Normal direction (from the primary volume to the secondary volume)

Reverse: Reverse direction (from the secondary volume to the primary volume)

Range

The pair resynchronization range

LU: Only the pair to be operated

Group: All pairs in the consistency group to which the pair to be operated belongs

No value is output if I/F Version is less than 0x04.

CTG

The consistency group ID

No value is output if I/F Version is less than 0x04.

No value is output if Range is LU.

Output items when Copy Type is TCMF

Fence Level

The fence level to be set (conditions where the local storage system rejects write operations to the primary volume)

Never: Can write to the primary volume even if the pair is split.

Data: Cannot write to the primary volume when update copying fails.

Status: Cannot write to the primary volume only when the storage system of the primary site cannot change the pair status of the secondary volume to PSUE

No value is output if Range is Group.

Copy Pace

The copy speed

Normal: Normal, Slow: Slow

Reverse Resync Mode

The setting status of the reverse resync mode

Enable: Enabled, Disable: Disabled

No value is output if I/F Version is less than 0x03.

Range

The pair resynchronization range

LU: Only the pair to be operated

Group: All pairs in the consistency group to which the pair to be operated belongs

No value is output if I/F Version is less than 0x04.

Change CTG

The setting status of the change mode of the consistency group attribute

None: Not changed

Open/MF CTG: Changes to the consistency group common to Open/Mainframe

CTG: Changes to the consistency group for the Mainframe

No CTG: Changes to a pair that does not belong to the consistency group

No value is output if I/F Version is 0x30 or less than 0x22.

Time Stamp

The transfer setting status of host time stamps to the secondary volume when resynchronizing pairs

Enable: Enabled, Disable: Disabled

No value is output if I/F Version is 0x20 or less than 0x16.

SCP

The setting status of SCP (Stage Change Pending) time change

Enable: Enabled, Disable: Disabled

No value is output if I/F Version is 0x30 or less than 0x22.

No value is output if Change CTG is not CTG.

CTG

The consistency group ID

No value is output if I/F Version is less than 0x04.

The consistency group ID of the pair change destination when Change CTG is Open/MF CTG or CTG

No value is output if Range is Group and Change CTG is No CTG.

No value is output if Range is LU and Change CTG is None or No CTG.

Output items when Copy Type is URMF

Error Stop

The setting status of the status change suppression when an error occurs

Enable: Enabled, Disable: Disabled

No value is output if I/F Version is less than 0x13.

A value is output only when Mode is Delta or Delta(Force) and Range is LU.

Reverse Resync Mode

The setting status of the reverse resync mode

Enable: Enabled, Disable: Disabled

Range

The pair resynchronization range

Group: All pairs in the same mirror as the pair to be operated

LU: Only the pair to be operated

EXCTG: All pairs in the extended consistency group to which the pair to be operated belongs

Error Level

The range of the pair split at failure occurrence

Group: All pairs in the same mirror as the pair to be operated are split

LU: Only the pair to be operated is split

No value is output if I/F Version is less than 0x12.

No value is output if Range is Group.

Mode

The copy mode

Normal: Normal

Suspend: Suspend

Delta: Delta resync

Delta(Force): Forcible delta resync

No value is output if I/F Version is less than 0x13.