Example 1: restoring LDEV
09xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,SVP,uid=user-name,,[Maintenance], Restore,,Normal end,from=xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx,, Seq.=xxxxxxxxxx +PG=[1-1],Num. of PGs=1
Detailed Information
Item |
Description |
---|---|
PDEV |
The location of the PDEV to be restored |
PG |
The parity group number E1-1: In the case of an external volume V1-1: In the case of a virtual volume X1-1: In the case of a Dynamic Provisioning volume |
Num. of PGs |
The number of parity groups |
LDEV |
The LDKC number, the CU number, and the LDEV number |
Num. of LDEVs |
The number of LDEVs |
Example 2: restoring a CTL (including CTL L), ENC, CFM, HIE, X-path cable, HSNBX, or ISW during replacement
09XX,0,YYYY/MM/DD,HH:MM:SS.xxx,00:00,GUM,,[Maintenance],Restore,,Normal end,Seq.=xxxxxxxxxx +Location=xxx
Detailed Information for Example 2
Item |
Description |
---|---|
Location |
The mounting location of the CTL, ENC, CFM, HIE, X-path cable, HSNBX, or ISW to be restored (CTLxx, ENCxxx-x, CFMxxx, HIE-xxx, ISWxx-x - HIE-xxx-x, HSNBX-x, or ISWxx). When replacing a FAN or cache memory, the mounting location of the CTL to be restored is output. (This is because the CTL on which the FAN or cache memory to be replace is mounted is restored.) |
Example 3: restoring a cache memory during replacement
09XX,0,YYYY/MM/DD,HH:MM:SS.xxx,00:00,GUM,,[Maintenance],Restore,,Normal end,Seq.=xxxxxxxxxx +Cache Size=xxxxxxxx,CFM Type for CFM010/020=xxx,CFM Type for CFM011/021=xxx
Detailed Information for Example 3
Item |
Description |
|
---|---|---|
Cache Size |
The cache size of the cache memory to be restored |
|
CFM Type for CFM010/020 |
The unit type of CFM010/020 that was installed A hyphen (-) is displayed if the unit is not changed or mounted. |
Displayed when a CFM of Node0 is installed. |
CFM Type for CFM011/021 |
The unit type of CFM011/021 that was installed A hyphen (-) is displayed if the unit is not changed or mounted. |
|
CFM Type for CFM110/120 |
The unit type of CFM110/120 that was installed A hyphen (-) is displayed if the unit is not changed or mounted. |
Displayed when a CFM of Node1 is installed. |
CFM Type for CFM111/121 |
The unit type of CFM111/121 that was installed A hyphen (-) is displayed if the unit is not changed or mounted. |
|
CFM Type for CFM210/220 |
The unit type of CFM210/220 that was installed A hyphen (-) is displayed if the unit is not changed or mounted. |
Displayed when a CFM of Node2 is installed. |
CFM Type for CFM211/221 |
The unit type of CFM211/221 that was installed A hyphen (-) is displayed if the unit is not changed or mounted. |
|
CFM Type for CFM310/320 |
The unit type of CFM310/320 that was installed A hyphen (-) is displayed if the unit is not changed or mounted. |
Displayed when a CFM of Node3 is installed. |
CFM Type for CFM311/321 |
The unit type of CFM311/321 that was installed A hyphen (-) is displayed if the unit is not changed or mounted. |
|
CFM Type for CFM410/420 |
The unit type of CFM410/420 that was installed A hyphen (-) is displayed if the unit is not changed or mounted. |
Displayed when a CFM of Node4 is installed. |
CFM Type for CFM411/021 |
The unit type of CFM411/021 that was installed A hyphen (-) is displayed if the unit is not changed or mounted. |
|
CFM Type for CFM510/520 |
The unit type of CFM510/520 that was installed A hyphen (-) is displayed if the unit is not changed or mounted. |
Displayed when a CFM of Node5 is installed. |
CFM Type for CFM511/521 |
The unit type of CFM511/521 that was installed A hyphen (-) is displayed if the unit is not changed or mounted. |
Example 4: restoring a CHB or DKB during replacement
09XX,0,YYYY/MM/DD,HH:MM:SS.xxx,00:00,GUM,,[Maintenance],Restore,,Normal end,Seq.=xxxxxxxxxx +Location=xxx,Type=xxxxxx
Detailed Information for Example 4
Item |
Description |
---|---|
Location |
The mounting location of the CHB or DKB to be restored (CHB-xxx or DKB-xxx) |
Type |
The unit type of the CHB or DKB to be restored |
Example 5: restoring a ACLF during replacement
09XX,0,YYYY/MM/DD,HH:MM:SS.xxx,00:00,GUM,,[Maintenance],Restore,,Normal end,Seq.=xxxxxxxxxx +Location=xxx,Forcibly run without safety checks=Disable
Detailed Information for Example 5
Item |
Description |
---|---|
Location |
The mounting location of the ACLF to be restored (BKMF-xxx) |
Forcibly run without safety checks |
Indicates whether the function of forcible replacement (without running safety checks) is enabled. |